Aluminum Alloy
Dingang
| Availability: | |
|---|---|
| Quantity: | |
In high-field magnetic environments—such as clinical 3T to 11.7T MRI systems, analytical NMR spectrometers, and cryogenic quantum computing cryostats—rapidly pulsed magnetic fields present serious engineering hurdles for exterior enclosures. When conventional metal sheets surround fast-switching magnetic coils, the magnetic field variations induce intense circulating electrical currents within the panels. These uncontrolled currents generate secondary counter-fields that blur imaging resolution, produce parasitic electrical heat that increases liquid helium boil-off rates, and generate violent mechanical forces that cause enclosure panels to buzz and rattle loudly in clinical and laboratory spaces.
Our Eddy-Current Suppressed Pre-Painted Aluminum Coil solves these operational challenges directly at the material level. By pairing high-resistivity, strictly non-magnetic structural alloys (AA5052 and AA5083) with an automated roller-applied dielectric barrier coating, this material breaks conductive ground loops across panel joints. Delivering verified electrical insulation exceeding 5,000 volts, complete magnetic neutrality near superconducting magnets, built-in acoustic damping, and exceptional stamping formability, this coil enables fast, reliable production of slotted covers, acoustic-quiet casings, and cleanroom-compliant magnet housings.
High-field magnet housings require materials that eliminate magnetic interference, suppress electrical loops, and quiet mechanical vibration without driving up assembly costs. Our Eddy-Current Suppressed Pre-Painted Aluminum Coil integrates calibrated alloy resistivity with factory-applied surface dielectric insulation into a single ready-to-form sheet. By using magnesium-alloyed AA5052 and AA5083, base electrical conductivity is engineered down to 30%–35% IACS, naturally reducing induced currents by roughly 75% compared to pure aluminum and minimizing parasitic heat near cryogenic vessels. Concurrently, our dual-side polymer coating delivers an electrical insulation barrier exceeding 5,000 volts, completely isolating overlapping sheet joints and fastener flanges without requiring manual insulating washers or gaskets. Supported by built-in viscoelastic vibration damping and strictly non-ferrous metallurgy, this material slashes cabinet fabrication time, eliminates field-distortion complaints, and ensures quiet, reliable scanner operation.
Zero Magnetic Field Warping: Strictly non-ferrous metallurgy eliminates magnetic hysteresis, protecting sub-millimeter diagnostic scan clarity.
Elimination of Manual Assembly Insulators: Continuous 5 kV dielectric coating insulates panel seams directly, removing the need for labor-intensive nylon gaskets and insulating films.
Over 75% Reduction in Induced Current: Controlled alloy resistivity chokes off current pathways, reducing heat transfer into liquid helium cryostats.
Integrated Surface Vibration Damping: Viscoelastic topcoat absorbs mechanical vibration caused by pulsing magnetic fields, quieting patient-room noise.
Flake-Free CNC Slotted Tooling: Flexible polymer matrix withstands high-speed laser cutting, punching of comb-like eddy breaks, and tight brake forming without edge chipping.
Parameter | Detailed Information |
|---|---|
Main Product | Brushed Surface Color Coated Aluminum Coil |
Optional Alloys | 1050, 1060, 1100, 3003, 3004, 3105, 5052, 5005, 5754, 5083, 6061, 8011 |
Available Tempers | O, H12, H14, H16, H18, H24, H26, H32, H34 |
Thickness Range | 0.2 mm – 1.6 mm |
Width Range | 30 mm – 1600 mm |
Inner Core Diameter | 76mm,150 mm, 405 mm, 505 mm |
Color Customization | RAL color system, Pantone color system, custom colors per samples |
Coating Thickness | PVDF coating ≥25 μm; PE coating ≥18 μm |
Standard Packaging | Export-grade wooden pallets (Eye to Wall / Eye to Sky loading modes) |
Minimum Order Quantity | 3 metric tons per specification |
Delivery Cycle | 30 – 45 working days |
Loading Ports | Shanghai, Ningbo, Qingdao, Tianjin and other major ports |
Payment Terms | 30% T/T deposit in advance, 70% balance against B/L copy; L/C at sight |
Every production run is executed under ISO 9001 and IATF 16949 quality frameworks to ensure certified electromagnetic neutrality, uniform dielectric insulation, and tight mechanical tolerances.
To support precision stamping facilities, medical device OEMs, and enclosure fabricators, we offer turnkey processing and supply chain services designed for clean manufacturing lines:
Equipped with high-precision rotary slitters, we provide narrow-width slit coils down to 60mm with deburred edges (under 0.02mm), ensuring smooth feeding into CNC punching and laser machines that cut comb-style eddy-current breaks.
While our standard dual-side coating provides 5 kV breakdown protection, we offer custom high-build formulations up to 60 microns that deliver over 10 kV dielectric insulation for specialized high-voltage and fast-pulsed scientific applications.
Coils are laminated with specialized halogen-free, anti-static protective PE films (70 to 100 microns) that protect the surface during multi-station press braking and punching without leaving sticky adhesive residues.
Finished coils and flat sheets are packed with moisture-proof VCI barriers, encapsulated in heavy-duty polyethylene, fitted with radial edge protectors, and secured onto non-magnetic or heat-treated wooden skids for international sea and air freight.
Modern clinical MRI systems employ high-amplitude gradient pulses that generate significant current loops and loud acoustic clatter in exterior service covers. Formed into front-facing aesthetic cowlings, bore liners, and rear service panels, our coil suppresses secondary magnetic fields to eliminate ghosting artifacts while dampening structural resonance to maintain a quieter, more comfortable patient environment.
Analytical chemistry and pharmaceutical laboratories rely on 600 MHz to 1.2 GHz NMR spectrometers where even trace magnetic field shifts destroy spectral line clarity. Fabricated into double-walled cryostat jackets and upper console covers, our low-induction sheets shield sensitive superconducting magnets from ambient electrical noise while preventing heat transfer to internal liquid helium reservoirs.
Quantum processors operate within millikelvin dilution refrigerators that are exceptionally vulnerable to stray electromagnetic fields and thermal drift. Our dielectric-coated aluminum sheets provide lightweight outer enclosure panels that isolate external radio-frequency interference and prevent parasitic eddy currents during precise magnetic flux tuning sequences.
Synchrotron light sources and cyclotron facilities pulse beam-steering dipoles at high frequencies, creating severe electromagnetic drag and structural vibration along vacuum tube runs. Using slotted, dielectric-insulated aluminum covers prevents electrical loop formation across support racks, ensuring precise sub-atomic particle trajectories without mechanical jitter.
National laboratory test benches generate extreme magnetic pulses that can warp conventional metal housings. Assembled into segmented, comb-slotted containment shields, our high-yield AA5083 coated panels break macro current paths, preventing structural deformation and protecting sensitive sensor instrumentation nearby.
Q1:Why is this material better than regular aluminum for MRI and NMR machine covers?
Pure aluminum conducts electricity too easily (around 62% IACS). When gradient magnetic fields pulse during scanning, large electrical currents form inside standard covers, generating counter-fields that blur scan images. Our material uses alloys with higher electrical resistance (30% to 35% IACS) and adds a factory dielectric coating, suppressing these currents by over 75% to keep the magnetic field stable and clear.
When bare metal panels are bolted together, they touch and form a large continuous electrical circuit around the magnet. Our coil comes pre-coated on both sides with a durable polymer layer that resists electrical breakdown up to 5,000 volts. This insulates overlapping seams, preventing currents from bridging across panels and eliminating the need for manual plastic washers.
When pulsing magnetic fields interact with electrical currents inside metal panels, rapid mechanical push-and-pull forces shake the sheet metal, creating an annoying rattling noise. Our coating incorporates a built-in viscoelastic damping layer that absorbs this vibrational energy, resulting in noticeably quieter equipment during intensive scan sequences.
No. The flexible polymer coating is rated for tight 1.5T bends and passes Class 5B cross-hatch adhesion tests. It shears and bends cleanly with the aluminum base during high-speed CNC punching, laser cutting, and press-brake forming, leaving smooth, fully insulated edges.
We supply gauges from 0.80mm to 3.00mm and widths from 600mm to 1500mm in AA5052-H34, AA5083-H111, and AA3003-H14 tempers, with custom coil weights from 1.0 to 4.0 metric tons to suit your factory stamping and brake-forming lines.
Are you designing next-generation MRI covers, NMR cryostat jackets, or low-induction enclosures for advanced magnetic systems? Contact our technical engineering team today to request physical dielectric-coated samples, ASTM test reports, and factory-direct quotations within 12 hours.
Products
Application
Quick links
Contact Us