PVDF Prepainted Aluminium Stripe For Exterior Blinds
You are here: Home » Brushed Surface » By Shape » Prepainted Aluminum Strip » PVDF Prepainted Aluminium Stripe For Exterior Blinds

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

PVDF Prepainted Aluminium Stripe For Exterior Blinds

Dingang PVDF prepainted aluminum strip is roll-forming stock for exterior venetian blinds and louvres, supplied in 3003/3005/3105 H24 with custom slit widths, RAL colors and durable outdoor coating.
  • PPAL

  • DINGANG

Availability:
Quantity:

PVDF Prepainted Aluminum Strip for Exterior Venetian Blinds

PVDF prepainted aluminum strip is coated roll-forming material designed for exterior venetian blinds, horizontal blind slats, architectural sun-shading louvres and other outdoor shading systems. The material is supplied in coil, slit-strip or slat-ready form for sectional rolling, pressing and forming processes.

Common substrate options include AA3003, AA3005 and AA3105 in H24 temper. These aluminum-manganese alloys combine practical formability, corrosion resistance and sufficient strength for suitable exterior blind profiles, while the PVDF coating provides a factory-finished surface for applications exposed to sunlight and outdoor weather.

Dingang supplies customized thicknesses, slit widths, colors and coating requirements for blind manufacturers and architectural shading-system suppliers. RAL K5, RAL K7, Pantone, wood-grain and customer-approved color references can be discussed according to project requirements.

Request PVDF Exterior Blind Strip Price

PVDF Aluminum Strip Specifications for Exterior Blinds

ProductPVDF prepainted aluminum strip for exterior venetian blinds and shading louvres
Common AlloysAA3003, AA3005, AA3105
Common TemperH24; other alloy and temper combinations should be confirmed before ordering
Listed Coating-Line Material Thickness Range0.024–2.00 mm; final blind-strip thickness should be selected according to profile and forming equipment
Listed Slitting Width Range15–2650 mm
Front Coating StructureNominal total 24 µm; primer 5 ±1.5 µm; finishing lacquer 19 ±1.3 µm for the listed coating specification
Listed Gloss at 60°30 ±5 units; maximum batch tolerance ±3 units
Color OptionsWhite, Silver, Anthracite Grey, Brown, wood grain, RAL K5/K7, Pantone and custom color matching
Supply FormCoils, narrow slit strips or application-specific slat material
Edge RequirementSlitting burr should be minimized to avoid feeding and forming problems
Inner Core MaterialPaper core
Inner Core Diameter405 mm / 505 mm
MOQ2–5 metric tons per specification
Main ApplicationsExterior venetian blinds, horizontal blind slats, sun-shading louvres, façade shading systems and compatible outdoor blind systems

Why Choose PVDF Coating for Exterior Blind Slats?

Designed for Outdoor Exposure

Exterior blind slats are exposed to sunlight, temperature changes, rain and atmospheric contamination. A PVDF coating system can be selected when enhanced outdoor weather resistance and color stability are required compared with general-purpose coating systems.

Color Retention for Architectural Façades

Exterior blinds are often visually integrated with façades, window systems and architectural cladding. Consistent color and controlled gloss are therefore important when several slats, coils or production batches are used on the same building.

Coating Flexibility for Slat Forming

Blind strip must usually pass through rolling, pressing, bending or profiling operations. The coating needs sufficient flexibility and adhesion to tolerate the intended forming sequence without unacceptable cracking or delamination.

Corrosion-Resistant Aluminum Substrate

AA3003, AA3005 and AA3105 are aluminum-manganese alloys widely used in formed architectural products. Combined with appropriate pretreatment and exterior coating, they provide a practical substrate for outdoor shading components.

PVDF Front-Side Coating Performance Reference

The following values summarize the listed coating-performance specification associated with this product range. Final test methods, coating system and acceptance criteria should be confirmed in the purchase specification before production.

No.Test ItemListed RequirementListed Test Basis
1Coating ThicknessTotal nominal thickness 24 µm; primer 5 ±1.5 µm; finishing lacquer 19 ±1.3 µmASTM D 1400 listed in the existing specification; current applicable film-thickness method should be agreed before ordering
2Gloss at 60°30 ±5 units; maximum tolerance per batch ±3 unitsASTM D 523
3Color ReferenceListed reference no. 2000 corresponding to NCS S-7500-N Cool Grey;
ΔL* = ±0.7;
Δa* = ±0.7;
Δb* = ±0.7;
maximum ΔE*ab = 1.0;
reference values L = 38.5, a = 0.12, b = -0.15
ASTM D 2244; listed geometry 45/0; 2° observer; CIELAB system
4Pencil HardnessMinimum FASTM D 3363
5Resistance to Rapid DeformationNo cracking after impact of 10 Nm per mm thicknessASTM D 2794
6Lacquer Resistance / Erichsen MethodNo dissolution of lacquer after 4 mm deformation when evaluated by adhesive tape testEN ISO 1520:1995 as listed in the existing specification
7T-Bend at 22 ±2°C1TASTM D 4145
8QUV Weathering1000 h;
measured on washed components;
listed gloss-retention requirement: minimum 10% of original gloss;
maximum color change ΔE*ab ≤5
ASTM G 53 listed in the existing specification; current UV exposure method should be agreed before ordering
9Natural Weathering ReferenceMeasured on washed components;
gloss retention: 80% of original gloss;
maximum color change ΔE*ab ≤5
Florida 45° South after 3 years; gloss ASTM D 523; color ASTM D 2244
10Salt Fog Resistance1008 h neutral: no blister formation or lacquer dissolution on untreated material corners;
504 h acetic acid: no blister formation or lacquer dissolution; maximum migration from cutting edge 1.5 mm
ASTM B 117 / ASTM B 287 as listed in the existing specification
11Water Immersion Resistance1000 h at 40°C;
no blister formation or lacquer dissolution on untreated material corners;
maximum migration from cutting edge 0.5 mm
ASTM D 870

Discuss Your PVDF Coating Specification

PVDF vs. Polyester Coating for Exterior Blinds

Selection FactorPVDF CoatingPolyester / PE Coating
Typical PositioningPremium exterior applications with higher weathering requirementsGeneral-purpose and more cost-sensitive applications
UV ExposurePreferred where stronger resistance to long-term outdoor UV exposure is requiredSuitable where exposure requirements are less demanding and the selected coating specification is adequate
Color RetentionSelected when long-term exterior appearance is a primary requirementProvides a practical decorative finish for appropriate service conditions
Recommended Selection BasisBuilding location, sunlight exposure, climate and specified weathering performanceProject budget, installation environment and required service conditions

Designed for Exterior Venetian Blind Slat Forming

Exterior venetian blind slats are manufactured by converting flat aluminum strip into a profiled blade or louvre. Depending on the blind design, the production process may include continuous feeding, pressing, roll forming, edge shaping, punching or cutting.

Stable strip width, consistent material condition and predictable coating flexibility help manufacturers maintain repeated profile geometry during continuous production.

For a new slat profile or production line, the strip thickness, feed width, alloy, temper and bending radius should be confirmed against the forming equipment before bulk production.

Precision Slitting and Edge Burr Control

The listed color-coated aluminum slitting capability ranges from 15 mm to 2650 mm. This allows strip width to be selected according to the flat feed requirement of the blind or louvre manufacturing line.

For blind production, width consistency is important because dimensional variation can affect the finished slat profile, edge geometry and downstream assembly.

Slitting burr should be kept as small as practical. Excessive burr can interfere with material feeding, contact tooling, create handling problems or affect the edges of finished blind slats.

Color Options for Architectural Blind Systems

RAL and Pantone Colors

Color-coated blind strip can be matched to RAL K5, RAL K7, Pantone or an agreed customer color reference. This is useful when blinds need to coordinate with windows, curtain walls, façade panels or other exterior architectural materials.

Anthracite Grey and Neutral Architectural Colors

White, Silver, Anthracite Grey and Brown are listed options for exterior blind and façade applications. Project-specific shades should be approved before bulk production.

Wood-Grain and Decorative Finishes

Wood-look and other decorative finishes can be discussed for shading systems requiring a warmer or more distinctive architectural appearance. The exterior suitability of each finish should be confirmed according to the coating construction and installation environment.

Request RAL or Custom Blind Colors

Typical Applications

  • Exterior venetian blind slats

  • External horizontal blinds

  • Architectural sun-shading louvres

  • Façade sun-control systems

  • Balcony shading systems

  • Window shading blades

  • Compatible motorized blind systems

  • Other roll-formed exterior shading profiles

Material Selection for Exterior Blind Manufacturers

1. Confirm the Blind or Louvre Profile

Provide the finished slat profile or flat-strip feed requirement. Profile geometry determines the width, forming sequence and minimum bend requirements of the material.

2. Confirm Alloy and Temper

Common listed options include AA3003, AA3005 and AA3105 in H24 temper. Final selection should be based on required stiffness, formability and production-line conditions.

3. Confirm Material Thickness

Material thickness affects slat stiffness, finished weight and forming behavior. The listed coating-line capacity is broad, so the actual blind-strip thickness should be specified according to the finished profile rather than selected from the full production capability.

4. Specify the Slit Width

Provide the flat strip width required by the forming line. For existing blind products, using the previously approved feed width can simplify material qualification.

5. Define the PVDF Coating Requirement

Specify coating thickness, primer, topcoat, gloss, color tolerance, bending requirement and any requested weathering or corrosion test criteria.

6. Confirm Color Reference

Provide the required RAL, Pantone, NCS or approved physical sample. For repeat projects, identify the previously approved batch or color specification where possible.

7. Confirm Coil Core and Weight

The listed paper-core inner diameters are 405 mm and 505 mm. Core size and coil weight should be checked against the customer's uncoiler, feeder or production line.

Incoming Quality Checks for Blind Production

Thickness and Width Consistency

Check thickness and slit width against the approved production specification before loading the coil onto a continuous forming line.

Coating Appearance

Inspect the visible surface for scratches, dents, coating defects, stains, color variation and other defects that may remain visible on the finished blind slat.

Edge Burr

Inspect the slit edges for excessive burr or distortion that could affect handling, feeding or profiling.

Bending and Forming Trial

For a new profile, thickness or coating configuration, a forming trial is recommended to verify bend behavior, coating condition and final slat geometry before bulk production.

Color Consistency

Where several coils will be installed on the same façade, compare supplied material with the approved color reference before production to reduce visible variation between blind sections.

Ordering and Packing Information

Minimum Order Quantity2–5 MT per specification
Essential Inquiry InformationAlloy, temper, thickness, slit width, PVDF coating requirement, color reference and final blind application
Supply FormatCoils, slit strips or application-specific slat material according to customer requirements
Inner Core MaterialPaper core
Inner Core Diameter405 mm / 505 mm
Outer ProtectionPaperboard
Ocean Shipment PackingWooden pallet with suitable runners, protection and securing materials for sea transportation

Send Your Exterior Blind Strip Specification

Frequently Asked Questions

What is PVDF prepainted aluminum strip used for?

It is used as prefinished forming material for exterior venetian blinds, horizontal blind slats, architectural sun-shading louvres and related outdoor shading profiles.

Which aluminum alloys are commonly used for exterior blind strip?

The listed options include AA3003, AA3005 and AA3105, commonly in H24 temper. The final alloy and temper should be selected according to profile geometry, stiffness and forming requirements.

Why use PVDF instead of PE coating for exterior blinds?

PVDF is generally selected for more demanding exterior applications where enhanced resistance to UV exposure, weathering and long-term color change is required. PE remains an option for suitable lower-demand or more cost-sensitive applications.

What is the listed PVDF coating thickness?

The listed front-side specification has a nominal total coating thickness of 24 µm, consisting of approximately 5 µm primer and 19 µm finishing lacquer within the stated tolerances.

Can strip width be customized for a blind production line?

Yes. The listed slitting capability covers 15–2650 mm. The actual slit width should be specified according to the flat feed requirement of the blind or louvre forming line.

Can you match RAL, Pantone or NCS colors?

RAL K5, RAL K7, Pantone and customer-specific color references can be discussed. Existing projects can also provide an approved physical sample for color evaluation.

Is wood-grain aluminum strip available for exterior blinds?

Wood-grain finishes are included in the listed decorative options. Exterior suitability should be confirmed according to the specific surface construction and required weathering performance.

Why is 1T bending performance important?

Blind slats are formed from flat strip into profiled shapes. Bending performance helps indicate whether the coated material can tolerate the required deformation without unacceptable coating cracking under the agreed test conditions.

Why is edge burr control important?

Excessive burr can create handling problems, interfere with material feeding and contact forming tools. Controlled slit edges are therefore important for continuous blind-slat production.

What coil core diameters are available?

The listed paper-core inner diameters are 405 mm and 505 mm. Buyers should confirm compatibility with their decoiler and feeding equipment.

What is the minimum order quantity?

The listed minimum order quantity is approximately 2–5 metric tons per specification. Final MOQ depends on alloy, thickness, width, PVDF coating and color requirements.

What information should I provide for a quotation?

Please provide alloy, temper, thickness, slit width, coating specification, color reference, gloss requirement, core diameter, coil weight, order quantity and destination. A blind slat drawing or forming-machine feed specification is also recommended.

Get a PVDF Exterior Blind Strip Quote

Previous: 
Next: 

Product Category

Consult Us To Get Your Customized Aluminum Solution

We help you specify and source the coated aluminum you need, on time and within budget.

Products

Application

Quick links

Follow Us

Contact Us

   joey@cnchangsong.com
    +86-18602595888
   Building 2, Zhixing Business Plaza, No.25 North Street, Zhonglou District, Changzhou City, Jiangsu Province, China
   Chaoyang road, Konggang economic development area, Lianshui, Huai'an city, Jiangsu,China
© COPYRIGHT 2026 CHANGZHOU DINGANG METAL MATERIAL CO., LTD. ALL RIGHTS RESERVED.