High Glossy Aluminum Coil
Dingang
7606125000
| Availability: | |
|---|---|
| Quantity: | |
AA1060 1.3mm antique bronze brushed aluminum combines a directional brushed texture with a decorative bronze-colored surface for architectural facade cladding, renovation panels, soffits, column covers and other exterior decorative components.
The standard featured specification uses AA1060 aluminum with a nominal thickness of 1.3mm and width of 1250mm. A PVDF-coated surface with a coating thickness of not less than 25μm is available for exterior projects, while other thicknesses, widths, colors and coating systems can be discussed according to project requirements.
The directional brushed texture creates the visual character of aged bronze without requiring the weight and cost structure of solid bronze sheet. Final appearance should be approved using a physical sample because bronze tone, brush direction, gloss and viewing angle can significantly influence the finished facade.
For curtain-wall and exterior cladding projects, the aluminum sheet is one component of the complete facade system. Panel dimensions, edge returns, stiffeners, substructure, fasteners, wind-load resistance, drainage, fire requirements and installation details should be engineered for the specific building.
Request Antique Bronze Aluminum Pricing
| Advantage | Technical and Purchasing Value |
|---|---|
| Antique Bronze Appearance | Directional brushing combined with an antique bronze color finish creates a metallic architectural appearance suitable for restoration-inspired and contemporary facade designs. Physical sample approval is recommended for color, brush direction and gloss. |
| Exterior PVDF Coating Option | PVDF coating of not less than 25μm is available for exterior applications. Required weathering, color-retention, chalking, adhesion or corrosion tests should be defined by the project specification. |
| Formable Aluminum Substrate | AA1060 offers useful formability for compatible cutting, bending and panel-fabrication operations. Final temper should be selected according to the required geometry and forming process. |
| Prefabricated Surface Finish | The decorative finish is applied before final installation, supporting controlled color and surface appearance for fabricated facade components when production batches and orientation are properly managed. |
| Recyclable Metal Substrate | Aluminum is recyclable. Project-specific environmental declarations, recycled-content data or green-building documentation should be evaluated separately when required. |
| Parameter | Available Specification |
|---|---|
| Featured Product | AA1060 1.3mm × 1250mm antique bronze brushed aluminum for exterior architectural decoration |
| Base Alloy | AA1060 aluminum |
| Featured Thickness | 1.3mm |
| Available Thickness Range | 0.2-2.5mm |
| Featured Width | 1250mm |
| Available Width Range | 60-1600mm |
| Temper | O / H12 / H14 / H16 / H18 / H24 / H26 according to the ordered AA1060 specification and forming requirement |
| Surface Appearance | Directional brushed texture with antique bronze color finish |
| PVDF Coating | Paint coating thickness not less than 25μm |
| PE Coating | Paint coating thickness not less than 18μm where a polyester system is specified |
| Color Options | Antique bronze, silver, white, black, red, blue, green and custom colors according to available coating systems and approved references |
| Color Reference | RAL / Pantone / approved physical sample where applicable |
| Coil Inner Diameter | 150mm / 405mm / 505mm and other agreed dimensions when supplied in coil form |
| Packing | Export wooden pallet packing; Eye-to-Wall or Eye-to-Sky coil orientation according to supply form and shipping requirements |
| MOQ | 2 tons per specification |
| Delivery Time | Approximately 30-45 days after order confirmation and deposit, subject to final specification and production schedule |
| Payment Terms | L/C at sight or 30% T/T deposit with 70% balance according to agreed commercial terms |
| Loading Ports | Shanghai / Ningbo / Qingdao / Tianjin or other agreed port |
| Typical Applications | Exterior facade cladding, decorative wall panels, renovation panels, soffits, column covers, entrance features and architectural decorative components |
For project quotation, provide panel or sheet dimensions, required temper, antique bronze appearance reference, brush direction, PVDF or other coating requirement, fabrication drawing, quantity and destination.
Send Your Facade Material Specification
The brushed texture creates fine directional lines across the aluminum surface. Light reflects differently depending on viewing direction, installation orientation and surrounding illumination, giving the facade a more dynamic metallic appearance than a completely smooth painted surface.
Antique bronze can be developed as a warm brown, copper-bronze or darker aged-metal appearance according to the approved reference. Because brush texture, gloss and metallic effects influence visual color, a physical sample is recommended for architectural approval.
Adjacent facade components should normally be installed with consistent brush direction unless the architectural design intentionally uses alternating orientations. Rotating individual panels can produce a visible difference even when the coating color is from the same production batch.
For large facade projects, define an approved master sample and acceptable color, gloss and texture variation. Where possible, visually adjacent panels should be coordinated by production batch and installation orientation.
A brushed color-coated aluminum surface and an anodized bronze surface are different finish systems and should not be specified interchangeably.
This configuration uses a brushed texture together with an organic color coating such as PVDF. The coating supplies the final antique bronze color and exterior surface system.
Anodizing converts the aluminum surface into an oxide layer, and bronze shades can be produced using appropriate anodizing and coloring processes. If the architectural specification requires anodized or electrolytically colored bronze rather than PVDF-coated bronze, identify that finish separately before material selection.
PVDF-coated bronze and anodized bronze can differ in gloss, metallic character, color variation, maintenance and weathering behavior. Architectural substitutions should be approved using representative samples and the required finish specification.
AA1060 is a commercially pure aluminum grade commonly selected for applications requiring useful formability and corrosion resistance without the higher strength of many 3xxx- or 5xxx-series alloys.
Temper influences stiffness, bendability and forming response. O and H-series tempers should be selected according to the required panel geometry, edge returns and fabrication process rather than appearance alone.
Where larger panels, higher wind loads or greater stiffness are required, the facade engineer should evaluate whether a different alloy, increased sheet thickness, formed returns or additional stiffeners are necessary.
The featured 1.3mm gauge can be used as decorative aluminum sheet for compatible fabricated facade and cladding components. It should not automatically be treated as a complete structural curtain-wall panel specification.
As panel width and unsupported span increase, stiffness and deflection become increasingly important. Final sheet thickness should therefore be evaluated together with panel dimensions, folded edges, stiffener layout and fixing positions.
Building height alone does not establish whether a sheet thickness is suitable. Design wind pressure, panel geometry, support spacing, corner zones, fixing system and local building requirements must be considered in the facade engineering calculation.
Where flat sheet is fabricated into a cassette or folded panel, edge returns and stiffeners can substantially affect panel rigidity. The final fabricated construction should follow approved shop drawings.
The available PVDF paint specification uses a coating thickness of not less than 25μm. When coating construction is contractual, define whether the required thickness refers to total dry-film thickness and identify the primer, topcoat and any additional coating layers.
PVDF systems can be selected for exterior architectural exposure, but the term PVDF alone does not establish a fixed service life. Performance depends on resin formulation, pigment, pretreatment, coating construction, UV exposure, climate, atmospheric contamination and fabrication quality.
If the architectural specification requires AAMA 2605 performance, identify that requirement before ordering. Compliance should be supported by documentation applicable to the actual coating system, pretreatment, substrate and production process rather than assumed solely from the use of PVDF resin.
For coastal, industrial or other aggressive environments, specify the required corrosion or salt-spray test together with exposure duration and acceptance criteria. Cut edges, fasteners, drainage and contact with dissimilar metals should also be addressed in the complete facade system.
No exterior bronze finish should be described as permanently fade-free. Where color retention is important, define the required coating specification, approved color reference and applicable weathering performance.
A polyester coating option of not less than 18μm is also available. PE and PVDF should not be treated as equivalent coating specifications for demanding exterior projects.
When the material will be exposed to long-term exterior sunlight and weather, coating selection should follow the architectural performance requirements rather than price or color alone.
Antique bronze brushed aluminum can be fabricated into compatible facade panels and exterior decorative elements where the final panel construction is engineered for the building and installation system.
The bronze appearance can be used in renovation projects where architects want a traditional or aged-metal visual character without specifying solid bronze sheet. Historic buildings may require separate conservation, planning and material approvals.
Brushed bronze aluminum can provide a directional metallic appearance for entrance surrounds, decorative wall panels and architectural feature areas.
Suitable material can be fabricated for soffits and canopy components where the sheet thickness, support system and coating specification meet the project requirements.
The material can be curved or folded into suitable decorative column-cover components after the required bend radius and surface condition have been validated.
Brushed antique bronze sheet can also be evaluated for fabricated screens, fins and other non-load-bearing architectural decorative components according to the project drawing.
Cutting and shearing operations should minimize visible edge deformation and scratching. Protective measures should be used where the decorative face remains exposed after fabrication.
Bend performance depends on temper, gauge, bend radius, rolling direction and coating flexibility. Tight folds should be validated using representative production material to check for coating cracking, whitening or loss of adhesion.
Curved panels should be evaluated against the actual radius, panel dimensions and fabrication method. No universal minimum bending radius should be assumed without confirming temper, coating construction and tooling.
Where perforation or CNC processing is required, provide hole pattern, open area, edge distances and finished component dimensions. Processing can influence stiffness and visible surface condition.
Fabrication drawings should identify the required brush direction so parts are cut and assembled consistently across the facade.
Wind-load resistance is a property of the complete panel and support system. Panel thickness alone does not establish suitability for a high-rise or low-rise building.
Large facade panels may require formed returns, stiffeners or additional support. Their size, spacing and attachment should follow the structural design.
Facade joints, cavities, flashings and drainage paths should be designed as part of the complete building envelope. The aluminum sheet itself does not establish water-tightness of the curtain-wall system.
A decorative aluminum face sheet does not by itself determine the U-value or insulation performance of the wall assembly. Insulation thickness, thermal bridges, substructure and the complete wall build-up must be evaluated separately.
Where a facade project requires a specific reaction-to-fire or system fire classification, provide the applicable standard and required classification. The coating, insulation, backing, substructure and complete wall assembly may all affect compliance.
Where aluminum contacts copper, carbon steel or other dissimilar metals in the presence of moisture, suitable separation and fastening details should be considered to reduce galvanic-corrosion risk.
AA1060 alloy and the required temper should be identified in the purchase specification and supported by applicable material documentation where contractual.
Nominal thickness, width and dimensional tolerance should be agreed according to panel-fabrication and project requirements.
The directional texture should be inspected for consistency where the brushed appearance remains visible on installed panels.
Where numerical color difference is contractual, define the approved master sample, instrument, illuminant, measurement geometry and acceptance limit rather than relying only on visual color names.
Specify the required gloss level and measurement geometry where gloss is part of the architectural appearance specification.
PVDF or PE dry-film thickness should be measured against the agreed coating construction where it is a contractual requirement.
Where coating adhesion is critical, identify the required test method and acceptance criterion. Post-forming adhesion may also need to be evaluated where panels are folded after coating.
Visible material should be inspected for unacceptable scratches, dents, stains, roller marks, coating defects, brush inconsistency and other conditions that may remain visible after fabrication and installation.
Available certificates and test documents should be reviewed against the required product, production batch, coating system, test standard and destination-market requirements before they are used for project approval.
Prepainted aluminum is packed to reduce moisture exposure, coating damage and edge deformation during storage, handling and international transportation.
Standard export packing can include moisture-proof paper and waterproof outer wrapping according to product form and shipment requirements.
Wooden pallets are used to support the material during handling and container transportation. Eye-to-Wall or Eye-to-Sky packing can be arranged for coil shipments where applicable.
If a project requires specific pallet dimensions, lifting positions, container-loading orientation or protective packaging, provide those requirements before order confirmation.
State whether the material will be fabricated into facade panels, soffits, column covers, entrance features, screens or another architectural component.
Specify AA1060 and the required temper according to forming and structural requirements.
Confirm whether the featured 1.3mm thickness is suitable for the fabricated component. Larger facade panels may require different thickness or additional stiffening according to structural design.
The featured width is 1250mm, with widths from 60mm to 1600mm available. Provide finished panel dimensions and fabrication allowances where applicable.
State whether the project requires brushed antique bronze PVDF-coated aluminum or a different finish such as anodized bronze. These finish systems should be specified separately.
Provide an applicable RAL, Pantone or physical reference and approve a representative sample for color, gloss and brushed appearance.
Identify the required brush orientation relative to panel length and installed facade direction.
If PVDF, AAMA 2605, weathering, salt-spray, adhesion, gloss retention or color-retention requirements are contractual, provide the required standard, test method and acceptance criteria.
Provide bend lines, edge returns, radii, perforations, holes and other fabrication details where they affect material forming or coating condition.
Identify required material certificates, coating data, test reports, third-party inspection or other project documentation before production.
Provide quantity for each specification together with delivery destination and packing requirements. Standard MOQ is 2 tons per specification.
Send Your Drawing & Color Reference
The featured specification is AA1060 aluminum with a nominal thickness of 1.3mm and width of 1250mm, using an antique bronze brushed decorative finish.
The available thickness range is 0.2mm to 2.5mm.
The available width range is 60mm to 1600mm, with 1250mm used for the featured specification.
No. Final suitability depends on panel dimensions, wind pressure, edge returns, stiffeners, fixing system and facade engineering. The 1.3mm sheet should be evaluated as part of the complete fabricated cladding system.
Not necessarily. A brushed PVDF-coated bronze finish and an anodized bronze finish use different surface-treatment systems. Specify the required finish before ordering.
The listed PVDF paint coating thickness is not less than 25μm.
The listed polyester paint coating thickness is not less than 18μm.
No. If AAMA 2605 performance is required, it should be specified with the order and supported by documentation applicable to the actual coating construction and production process.
A fixed service life should not be assumed from the coating-family name alone. Actual weathering depends on coating formulation, color, climate, UV exposure, installation and environmental conditions. Any project warranty should be confirmed separately.
It can be evaluated for coastal applications with a suitable coating system and facade design. Salt exposure, cut edges, fasteners, drainage and galvanic contact should be considered as part of the complete system.
The antique bronze appearance can be considered for renovation projects requiring an aged-metal visual effect. Historic or protected buildings may also require approval from the relevant architect, owner or heritage authority.
Yes. Custom color matching can be discussed using an applicable RAL or Pantone reference or an approved physical sample. Physical samples are preferred when the brushed metallic appearance is important.
Yes. Directional surfaces can appear lighter or darker when rotated. Panel cutting and installation orientation should therefore be controlled where a uniform appearance is required.
AA1060 can provide useful forming capability, but minimum radius depends on temper, thickness, coating construction, grain direction and tooling. Representative material should be tested for demanding curves or folds.
No. Building thermal performance depends on the complete wall assembly, insulation, air layers, thermal bridges and installation. The decorative aluminum face alone does not establish the wall U-value.
Do not assume a fire classification without an applicable test report. Required fire performance should be confirmed for the actual material construction and, where necessary, the complete facade assembly.
No. Green-building credits depend on the project rating system and supporting documentation. Recycled content, environmental declarations, sourcing and other project-specific criteria should be evaluated by the project team.
Samples can be provided for evaluation, with shipping costs borne by the buyer. Color sample timing and final availability should be confirmed with the requested specification.
The listed minimum order quantity is 2 tons per specification.
Mass-production lead time is approximately 30-45 days after order confirmation and deposit, depending on color, coating, dimensions, quantity and production schedule.
Please provide application, AA1060 temper if specified, thickness, width, panel dimensions, antique bronze reference, brush direction, PVDF or PE coating requirement, coating thickness, fabrication drawing, required tests or certificates, quantity, packing requirements and delivery destination.
If you are sourcing AA1060 antique bronze brushed aluminum for facade cladding, renovation panels, soffits or other architectural exterior components, send us your dimensions, finish reference, coating specification, fabrication requirements and order quantity for technical confirmation and quotation.