Aluminum Alloy 3003 Marble Designed Pattern Coating Aluminum Sheet
Dignang Metal
7606125900
| Availability: | |
|---|---|
| Quantity: | |
High-gloss marble pattern coated aluminum sheet is a solid prepainted aluminum material designed for building facades, wall cladding, rainscreen panels, decorative exterior walls and other architectural components requiring a stone-inspired appearance with lightweight metal fabrication.
Unlike natural marble, the decorative effect is produced on an aluminum substrate, allowing the material to be cut, bent, folded and fabricated into suitable architectural panels while providing a consistent marble-inspired surface across larger project areas.
The current product range covers approximately 0.20–3.00mm metal thickness and widths from 30–1500mm. Available alloys include AA1060, 1100, 3003, 3005, 3105 and 5052, with H16, H24 and other project-specific tempers subject to confirmation.
For exterior facade projects, the required coating chemistry, marble pattern, gloss level, pattern direction, color consistency, panel dimensions and fabrication method should be confirmed before production.
Request Marble Pattern Samples

| Parameter | Current Specification | Project Notes |
| Product Type | Marble Pattern Prepainted Aluminum Coil / Sheet | Solid aluminum substrate for architectural fabrication |
| Primary Application | Facade panels / wall cladding / rainscreen / decorative wall panels | Final structural suitability depends on the complete cladding system |
| Aluminum Alloys | AA1060 / 1100 / 3003 / 3005 / 3105 / 5052 | Select according to strength, forming and project requirements |
| Temper | H16 / H24 / project-specific | Final temper should match metal thickness and fabrication process |
| Metal Thickness | 0.20–3.00mm | For facade panels, final thickness should be selected according to panel size, folds, stiffeners and wind design |
| Width | 30–1500mm | Provide finished or master-coil width according to fabrication requirements |
| Marble Pattern | Custom marble / stone / granite-inspired designs | Physical sample or approved artwork recommended |
| Other Patterns | Wood / stone / wrinkle / project-specific patterns | This page is primarily intended for marble-effect facade applications |
| Surface Finish | High Gloss / Gloss / Semi-Gloss / Satin / Matte subject to coating system | For this product, high-gloss marble is the primary finish |
| High-Gloss Reference | >80 gloss units where measured on an appropriate smooth surface | Gloss method and tolerance should be agreed before production |
| PE Paint Layer | Current source reference >18μm | More suitable for appropriate general or interior applications unless exterior performance is separately validated |
| PVDF System | Available according to project requirement | Typically preferred for demanding exterior facade exposure |
| PVDF Film Reference | Current source table: ≥22μm or ≥30μm depending on coating construction | Exact primer, topcoat and clear-coat structure should be specified |
| Coil Inner Diameter | 405 / 505mm and other compatible options | Confirm according to decoiling equipment |
| Color Reference | RAL / custom physical sample / approved artwork | Marble veining normally requires sample-based approval rather than RAL alone |
| Pencil Hardness | Current general reference ≥1H; separate source specification lists >2H | Use one agreed contractual value for the selected coating system |
| T-Bend | Current reference ≤2T for PVDF / ≤3T for PE and other coatings | Important where the sheet is folded after coating |
| Impact Resistance | Current reference 50kg·cm without visible coating loss or cracking | Test method and acceptance criteria should be agreed |
| MEK / Solvent Resistance | Current references ≥70 for PVDF / ≥50 for PE and other systems | Can be used as a coating-cure reference where applicable |
| Protective Film | Optional | Recommended for high-gloss surfaces during fabrication and installation |
| Supply Form | Coil / Sheet / Strip / Slat | Facade projects typically use coil for further fabrication or cut sheets |
High-gloss marble-pattern aluminum is designed to reproduce the visual character of polished stone while retaining the fabrication advantages of aluminum.
The surface can reproduce light and dark marble veining, stone-like color transitions and customized architectural patterns without relying on a full-thickness natural stone slab.
A high-gloss clear or finish layer can increase visual depth and create a polished-stone effect, particularly on dark marble, white marble and strongly veined designs.
Facade projects often use many adjacent panels. Pattern scale, vein direction, gloss and overall color tone should therefore be approved as a coordinated system rather than inspecting each panel only as an isolated piece.
Customers can provide a natural stone sample, printed reference, digital artwork or approved architectural rendering for pattern development.
The final appearance should be confirmed using a physical coated sample before bulk production.
The phrase “high gloss” should be supported by a measurable gloss target where surface appearance is contract-critical.
For suitable smooth coil-coated aluminum surfaces, a 60-degree gloss value above 80 gloss units is generally classified as high gloss under current EN 1396 terminology.
| 60° Gloss Range | Finish Description |
| ≤10 GU | Matte |
| >10–20 GU | Low Gloss |
| >20–40 GU | Satin |
| >40–60 GU | Semi-Gloss |
| >60–80 GU | Gloss |
| >80 GU | High Gloss |
For textured, embossed, metallic, pearlescent or strongly patterned surfaces, instrumental gloss and color measurements may not fully represent visual appearance. In these cases, a physical master sample and agreed viewing conditions are particularly important.
Request High-Gloss Finish Samples
This product is based on solid aluminum sheet or coil and should not automatically be confused with aluminum composite panel, commonly called ACP or ACM.
| Comparison | Solid Marble-Pattern Aluminum Sheet | Typical Aluminum Composite Panel |
| Core | No polymer or mineral core within the sheet itself | Includes a separate core between aluminum skins |
| Metal Thickness | Current product range 0.20–3.00mm | Usually defined by panel thickness plus individual aluminum skin thickness |
| Fabrication | Can be cut, folded, bent and formed according to alloy, temper and gauge | Typically routed, folded and fabricated as a sandwich panel |
| Fire Classification | Cannot be inferred from aluminum sheet alone when installed as a complete facade system | Depends strongly on core and complete panel construction |
| Specification | Alloy, temper, gauge, coating and fabricated panel design | Total panel thickness, skin gauge, core, coating and panel construction |
For long-term exterior facade applications, a project-qualified PVDF coating system is generally a more appropriate starting point than basic interior-grade polyester where strong resistance to UV exposure, chalking and color change is required.
The full PVDF construction should identify pretreatment, primer, decorative marble layer, topcoat or clear coat and reverse-side coating where applicable.
Where available, FEVE and other exterior architectural fluoropolymer systems can also be evaluated according to gloss, pattern appearance, forming and project performance requirements.
PE polyester can be suitable for many interior decorative applications and selected exterior projects where the actual paint system and project exposure support its use.
The term PE alone should not be treated as a universal long-term facade performance guarantee.
The aluminum base provides the formable metal structure for subsequent facade-panel fabrication.
The aluminum surface is cleaned and pretreated to support corrosion resistance and coating adhesion.
A primer provides adhesion between the prepared substrate and the decorative coating layers.
A background color can establish the primary tone of the marble or stone pattern.
The marble design is transferred or printed according to the approved pattern, scale, vein direction and project requirements.
A compatible high-gloss finishing layer can provide the required surface appearance and additional protection of the printed design.
The reverse side can receive a backing coat or primer according to fabrication, bonding and environmental requirements.
Natural marble has a directional grain and vein structure. The same design principle should be considered when marble-effect aluminum panels are installed across a large facade.
The purchaser should specify whether marble veins should run vertically, horizontally or according to a numbered panel layout.
Printed marble patterns can repeat at defined intervals depending on the production technology. Where repeated motifs would be visible on a large elevation, the pattern repeat should be reviewed before approval.
Where the architectural concept requires visually coordinated adjacent panels, the required panel sequence and pattern orientation should be provided before fabrication.
Panels installed adjacent to each other should preferably use material produced against the same approved pattern and production standard to reduce unwanted differences in tone and gloss.
AA3003 provides moderate strength, useful formability and corrosion resistance, making it a practical choice for many folded architectural panels.
AA3005 and AA3105 can be considered for architectural coil-coated applications requiring a balance of forming capability and mechanical properties.
AA5052 provides higher substrate strength than many 3xxx-series alloys and can be evaluated where the fabricated panel requires additional mechanical performance.
Commercially pure aluminum grades can provide high formability for suitable decorative applications but generally have lower strength than AA3003 or AA5052.
| Thickness Range | Typical Selection Considerations |
| 0.20–0.50mm | Suitable for compatible decorative skins, laminates, trim and lightweight fabricated components |
| 0.50–1.00mm | Can be used for suitable decorative panels and formed architectural components where supporting structure is provided |
| 1.00–2.00mm | Provides increased metal body for folded cladding and facade-panel applications |
| 2.00–3.00mm | Can be considered for heavier solid-aluminum panel fabrication where project engineering supports the selected gauge |
Metal thickness alone does not determine panel wind resistance or structural adequacy. Panel dimensions, folds, stiffeners, supports, bracket spacing, fasteners and wind pressure must be evaluated together.
Marble-effect aluminum can be fabricated into suitable facade panels where a polished stone-inspired appearance and lightweight metal construction are required.
The material can be incorporated into compatible ventilated rainscreen systems using appropriate panels, rails, brackets and fixings.
High-gloss marble patterns can be used for suitable entrance walls, columns, canopies and feature areas on hotels, offices, shopping centers and other commercial buildings.
Stone-inspired aluminum can provide a decorative focal surface without using full-thickness marble slabs.
The same marble-effect material can be used for compatible interior walls, elevator surroundings, retail displays, reception areas and decorative ceiling elements.

Wind resistance is a property of the complete facade system rather than the decorative aluminum sheet alone.
Panel dimensions, thickness, return depth, stiffeners, brackets, rails and fasteners should be engineered for the applicable project wind pressures.
Aluminum expands and contracts with temperature. Large panels and dark marble patterns can experience significant solar heating, so movement allowance should be incorporated into the facade design.
Rainscreen cavities and joints should be designed to manage water penetration, drainage and ventilation according to the complete wall construction.
Fastener and substructure materials should be selected to minimize unwanted galvanic interaction with aluminum in wet conditions.
The fire classification of a facade cannot be established from the aluminum substrate or marble coating alone.
Where fire performance is required, the complete installed system including panel construction, insulation, membranes, substructure and cavity detailing should be evaluated against the applicable project standard.
Sheets can be cut into panel blanks using suitable equipment while protecting the decorative surface against scratching.
Compatible material can be folded into cassette or tray-type panels when alloy, temper, gauge, bend radius and coating flexibility are correctly selected.
Holes, slots and fixing details can be processed according to the fabricated-panel drawing.
High-gloss surfaces are particularly sensitive to scratches and handling marks. Temporary protective film can be applied where required for fabrication and installation.
The film should be compatible with the coating and removed within the period specified by the protective-film supplier.
The following values are cleaned from the existing product performance table. They should be treated as current reference values and linked to the exact coating system and agreed test method before being used contractually.
| Test Item | PVDF with Varnish | PVDF without Varnish | PE & Other Systems |
| Paint Film Thickness | ≥22μm | ≥30μm | ≥18μm |
| Gloss ≥80 GU | Current tolerance reference ±10 gloss units | ||
| Gloss 20–80 GU | Current tolerance reference ±7 gloss units | ||
| Gloss <20 GU | Current tolerance reference ±5 gloss units | ||
| Pencil Hardness | Current reference ≥1H | ||
| Abrasion Resistance | ≥5L/μm | ≥5L/μm | Project-specific |
| T-Bend | ≤2T | ≤2T | ≤3T |
| Impact Resistance | Current reference 50kg·cm without visible paint loss or cracking | ||
| Adhesion | Current reference ≥Class 1; test method should be confirmed | ||
| Boiling Water Resistance | No visible change under current reference test | ||
| Acid Resistance | No visible change under current reference test | ||
| Alkali Resistance | No visible change under current reference test | ||
| Oil Resistance | No visible change under current reference test | ||
| Solvent Resistance | ≥70 | ≥70 | ≥50 |
| Scrub Resistance | Current reference ≥10,000 cycles without visible change | ||
| Dirt Resistance | ≤15% | ≤15% | Project-specific |
| Salt-Spray Reference | Current source reference ≥Class 2 | Current source reference ≥Class 2 | Project-specific |
Gloss should be measured using the agreed method on a representative flat sample where instrumental testing is appropriate.
Marble-effect surfaces should be approved visually against a master sample because veining, pattern variation and gloss can affect instrumental color readings.
Primer, decorative coating and clear coat should be identified separately where the project specification requires detailed coating construction.
T-bend testing helps determine whether the coating can tolerate folding during facade-panel fabrication.
Impact testing can be included where fabrication or service conditions require additional coating deformation resistance.
Solvent-rub testing can provide information about coating cure where applicable to the paint chemistry.
Where exterior appearance retention is important, specify the test method, duration and acceptable color, gloss or chalking change.
Salt-spray tests should define exposure time, scribe condition and acceptable corrosion or blistering. Laboratory hours should not be converted directly into guaranteed facade service life.
For applicable coil-coated aluminum orders, the specification should clearly identify the product form, aluminum alloy, temper, metal substrate thickness, width and sheet length or coil dimensions.
The coating section should define the top-side coating, marble pattern reference, color, nominal gloss, protective film and reverse-side coating.
Special packing requirements, coil weight, pallet design, winding direction and inspection documentation should also be defined where applicable.
| Purchasing Item | Information to Provide |
| Application | Facade / rainscreen / wall panel / entrance / column / interior decorative wall |
| Material Type | Solid aluminum sheet or coil |
| Alloy | 1060 / 1100 / 3003 / 3005 / 3105 / 5052 or approved project specification |
| Temper | H16 / H24 or project-specific temper |
| Thickness | 0.20–3.00mm according to panel construction |
| Width | Specify finished sheet or master-coil width |
| Panel Length | Provide cut-to-length requirement where sheet supply is required |
| Marble Pattern | Provide image, stone reference, physical sample or approved artwork |
| Pattern Scale | Specify preferred vein and pattern scale |
| Pattern Direction | Vertical / horizontal / panel-layout-specific orientation |
| Pattern Repeat | Specify if a maximum visible repeat is required |
| Coating Type | PE / PVDF / FEVE or approved project system |
| High-Gloss Target | Specify nominal gloss units where measurable |
| Gloss Tolerance | Specify acceptable production variation |
| Color Acceptance | Approved physical master sample or agreed test criterion |
| Top-Coat Thickness | Specify coating build and dry-film requirement |
| Reverse Side | Specify backing coat or bonding primer |
| T-Bend | Provide forming requirement where panels will be folded |
| Protective Film | Specify type and removal requirement |
| Fabrication | Cutting / punching / folding / cassette-panel fabrication |
| Project Environment | Interior / inland exterior / industrial / tropical / coastal / high-UV |
| Quantity | Provide total area, sheet quantity or coil tonnage by pattern |
Send Your Facade Pattern Specification
| Ordering Item | Current Reference |
| MOQ | Current source reference approximately 1–5MT per specification |
| Essential Inquiry Information | Alloy, temper, thickness, width, coating type, marble pattern, gloss and quantity |
| Supply Forms | Coil / sheet / strip / slat according to requirement |
| Core Material | Paper core |
| Core Diameter | 405 / 505mm |
| Outer Protection | Paperboard and suitable protective packaging |
| Export Packing | Wooden pallet suitable for ocean transportation |
Marble-pattern aluminum production combines aluminum substrate preparation with controlled architectural coating and decorative pattern application.
The aluminum surface is cleaned and prepared according to the selected coating system.
Primer and background color establish adhesion and the base tone required for the marble design.
The marble or stone effect is applied according to the approved design reference and pattern direction.
A compatible gloss finish or protective clear layer is applied where required to produce the polished architectural effect.
The coating passes through the required curing process according to the paint chemistry and line conditions.
Finished material can be inspected for marble-pattern clarity, pattern direction, gloss, color, coating thickness, adhesion and dimensional accuracy.
The current company information states that Dingang operates aluminum and steel coating production equipment together with leveling, cleaning, embossing, cross-cutting and slitting capabilities for prepainted metal production.
Pattern-designed finishes can reproduce decorative effects including marble, stone, wood, terracotta, concrete and other project-specific appearances according to production capability and approved samples.


For project orders, buyers can request available material, coating and inspection documentation relevant to the exact supplied product.
Where a certificate, environmental declaration, coating test or inspection document is mandatory, the exact document requirement should be listed in the inquiry before order confirmation.

| Inspection Item | Recommended Control |
| Alloy & Temper | Verify against the approved substrate specification |
| Metal Thickness | Measure substrate thickness according to agreed tolerance |
| Width / Length | Check against ordered coil or sheet dimensions |
| Marble Pattern | Compare against approved pattern master |
| Pattern Direction | Confirm orientation according to project layout |
| Pattern Repeat | Review where large adjacent facade areas are involved |
| Color | Visual comparison against approved master sample |
| Gloss | Measure where appropriate and compare with nominal project requirement |
| Coating Thickness | Verify according to approved paint-system construction |
| Coating Adhesion | Test according to agreed cross-cut or other applicable method |
| T-Bend | Check where material will be folded into facade panels |
| Surface Appearance | Inspect for scratches, dents, streaks, coating defects and unwanted pattern variation |
| Protective Film | Check coverage, adhesion and removability where specified |
A physical facade mock-up is recommended for large projects using marble-effect aluminum.
The mock-up can help architects, contractors and fabricators evaluate marble scale, vein direction, gloss, panel joints, viewing distance and lighting conditions before approving full production.
Where multiple sheets will be folded into cassette panels, representative fabrication should also be included in the approval process.
After approval, the marble master pattern, pattern direction, gloss target, alloy, temper, thickness and coating structure can be retained as the repeat-order standard.
Request Samples for Facade Mock-Up
High-gloss patterned aluminum should be protected against scratching, rubbing, moisture and deformation during transportation.
The current export packing uses seaworthy wooden pallets with suitable paperboard and protective wrapping. Coil packing can be arranged with the axis oriented according to handling and shipment requirements.
Protective film is recommended where the high-gloss decorative face will be subjected to cutting, folding, stacking or installation handling.

For an accurate quotation, please provide the building application, aluminum alloy, temper, thickness, finished width or sheet size and required quantity.
Please also provide the marble or stone reference, pattern direction, required gloss, coating system, color acceptance method and protective-film requirement.
For exterior facade projects, provide the project location and exposure environment together with any PVDF, FEVE, weathering, salt-spray or other coating-performance requirements.
If the material will be fabricated into folded facade panels, provide panel dimensions, bend radii, return depth, punching details and other relevant drawings.
Request Technical Details & Pricing
It is solid aluminum sheet or coil finished with a decorative coating designed to reproduce a marble or stone-like appearance with a high-gloss surface.
No. This product is based on solid aluminum sheet or coil. An aluminum composite panel uses separate aluminum skins bonded to a core material.
Yes. Suitable gauges and exterior coating systems can be fabricated into compatible facade and cladding panels when the complete wall system is properly engineered.
The current range includes AA1060, 1100, 3003, 3005, 3105 and 5052.
The current product range is approximately 0.20–3.00mm.
The current range is approximately 30–1500mm.
For a suitable smooth coil-coated surface, a 60-degree gloss measurement above 80 gloss units can be used as a high-gloss reference.
Yes. High gloss, gloss, semi-gloss, satin and matte options can be discussed according to coating-system capability and approved samples.
Pattern matching can be discussed using a natural stone sample, photograph, design artwork or other approved reference. Final production should follow a physical approved sample.
Yes. Longitudinal, transverse or panel-layout-specific pattern direction can be specified before production where the manufacturing method permits.
Printed or transferred designs normally have a production repeat. Buyers should review pattern scale and repeat before approving material for large uninterrupted facade areas.
PVDF or another project-qualified architectural fluoropolymer system is typically considered for demanding exterior exposure. Final selection should follow the project climate, UV exposure and required appearance retention.
Some polyester systems can be used for suitable exterior applications, but basic PE coating should not automatically be assumed to provide the same long-term weathering performance as a qualified exterior PVDF or comparable system.
The current general specification lists PE above 18μm, while the existing detailed table includes PVDF references of at least 22μm or 30μm depending on coating construction. Final coating build should be confirmed before ordering.
Yes, compatible material can be folded when alloy, temper, gauge, bend radius and coating flexibility are correctly selected. A representative fabrication trial is recommended.
The current performance table lists ≤2T for PVDF and ≤3T for PE and other coating systems. Final contractual requirements should identify the exact coating and test method.
A thin aluminum facade skin generally has substantially lower material weight per square meter than a full-thickness natural stone slab, although the complete cladding-system weight depends on panel construction and substructure.
No complete facade fire classification should be inferred from the decorative aluminum sheet alone. Fire performance must be evaluated for the relevant panel and installed wall system.
Yes. Protective film can be supplied where the high-gloss surface needs protection during fabrication, transport and installation.
A physical master sample is recommended. For large facades, a full-size or representative mock-up can also be used to evaluate color, pattern scale, vein direction and gloss under real viewing conditions.
Yes. Coil, sheet, strip and slat supply can be discussed according to dimensions and production requirements.
The existing product information lists approximately 1–5 metric tons per specification as a current MOQ reference. Final MOQ should be confirmed according to pattern, coating, gauge and dimensions.
Please provide alloy, temper, thickness, width or sheet dimensions, marble pattern reference, pattern direction, gloss target, coating system, quantity, facade application and fabrication requirements.
If you require marble-effect aluminum for building facades, rainscreen panels, wall cladding or architectural feature panels, send us your pattern reference and material specification.
We can discuss 0.20–3.00mm aluminum, widths up to 1500mm, AA3003 and other alloy options, custom marble patterns, high-gloss finishes, PE / PVDF coating systems, protective film and project-specific fabrication requirements.