0.8mm Color Coated Aluminum Facade Sheet for Ecuador
You are here: Home » Brushed Surface » Prepainted Aluminum Coil & Sheet » Color Coated Aluminum Sheet » 0.8mm Color Coated Aluminum Facade Sheet for Ecuador

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

0.8mm Color Coated Aluminum Facade Sheet for Ecuador

0.8mm color coated aluminum facade sheet for Ecuador building projects, available in 3003, 3004, 3105 and 5052 alloys with PVDF, HDP or PE coatings, custom widths, colors and protective film.
Availability:
Quantity:

0.8mm Color Coated Aluminum Facade Cladding Sheet for Ecuador

0.8mm color coated aluminum facade sheet is designed for architectural cladding, curtain-wall skins, soffits, canopies, fascia and other non-structural exterior metal components used in commercial, residential and public building projects.

Available substrate alloys include AA3003, AA3004, AA3105 and AA5052, with alloy and temper selected according to panel size, forming severity, required stiffness and fabrication method. The standard product thickness is 0.8mm, with additional gauges from 0.4mm to 1.2mm available for compatible applications.

PVDF, high-durable polyester (HDP) and PE coating systems are available. For demanding exterior facade projects in Ecuador, especially coastal or high-UV environments, the exact coating resin, pretreatment, primer, topcoat, color pigments and exposed-edge design should be selected according to project conditions.

The aluminum sheet is supplied as material for further facade-panel fabrication. Wind resistance, water tightness, fire performance, fixing capacity and structural safety must be engineered and verified for the complete cladding or curtain-wall system.

Request Ecuador Facade Sheet Pricing

Technical Specifications

Property

Available Specification

Project Notes

Product

Prepainted Aluminum Facade Cladding Sheet

For architectural cladding and curtain-wall panel fabrication

Alloys

AA3003 / AA3004 / AA3105 / AA5052

Select alloy according to forming, stiffness and panel design

Temper

H14 / H24 / H16 / H26 according to alloy and project

Final alloy-temper combination should be confirmed before production

Standard Thickness

0.8mm

Facade skin thickness; structural adequacy depends on the complete panel system

Custom Thickness

0.4–1.2mm

Subject to panel geometry and production requirements

Widths

1000 / 1220 / 1250 / 1500mm

Custom widths can be discussed

Coating Systems

PVDF / HDP / PE

Select according to exterior exposure and performance requirement

Top-Coat Thickness

25–28μm

Confirm total coating construction for the selected paint system

Back-Coat Thickness

5–8μm

Back coating can be matched to panel fabrication requirements

PVDF Resin Requirement

Project-specific

Specify 70% PVDF where required by the architectural coating specification

Colors

RAL / Pantone / Physical Sample / Custom

Physical master sample recommended for facade projects

Gloss

Matte / Satin / Semi-Gloss / High Gloss

Numerical gloss target recommended for large elevations

Metallic / Effect Colors

Available according to coating system

Panel orientation should remain consistent during installation

Protective Film

Optional

Recommended for appearance-critical panel fabrication

Supply Form

Sheet / Coil / Slit Coil according to order

Match fabricator equipment and panel dimensions

Applications

Facade / Curtain Wall / Soffit / Canopy / Fascia / Siding

Non-structural skin material unless engineered otherwise

3003, 3004, 3105 and 5052 Alloy Selection

The appropriate aluminum alloy depends on panel geometry, forming requirements, sheet size and required mechanical strength.

AA3003

AA3003 is an Al-Mn alloy widely used for architectural and general sheet fabrication because it combines moderate strength, corrosion resistance and good formability.

AA3004

AA3004 provides higher strength than commercially pure aluminum and can be considered for compatible facade profiles requiring additional stiffness while retaining useful forming capability.

AA3105

AA3105 is commonly used in coated architectural sheet, siding and building components where formability and corrosion resistance are important.

AA5052

AA5052 provides higher strength and strong corrosion resistance and can be evaluated for more demanding fabricated components. The selected temper and bend geometry should be confirmed before production.

Why 0.8mm Aluminum for Facade Cladding?

A 0.8mm gauge offers a lightweight metal skin for compatible facade and cladding designs while remaining suitable for cutting, bending, profiling and other sheet-fabrication processes.

However, 0.8mm thickness should not be treated as a universal structural specification for every curtain-wall panel.

Panel Size Matters

Larger panels can experience greater deflection than smaller panels. Panel width, height, edge returns and intermediate stiffeners should therefore be considered together with skin thickness.

Wind Load Is a System Property

Resistance to wind pressure and suction depends on the aluminum skin, panel geometry, stiffeners, fasteners, brackets and supporting substructure.

Fabrication Matters

Grooving depth, bend radius, perforations and panel cut-outs can affect the remaining section strength and should follow the approved panel drawing.

PVDF Coating for Exterior Facades

PVDF fluoropolymer coatings are commonly selected for architectural metal exposed to demanding sunlight and weathering conditions.

70% PVDF Systems

Where the project specification calls for a high-performance architectural fluoropolymer coating, the purchase requirement should identify the required PVDF resin content, coating manufacturer and applicable performance standard.

A statement such as “PVDF coated” alone is not sufficient to define coating durability because different PVDF formulations and coating constructions can have different performance levels.

Two-Coat and Three-Coat Systems

A typical two-coat system includes primer and color topcoat. Three-coat constructions can include primer, color coat and clear coat or another approved finishing layer.

The appropriate system depends on color, metallic effects, exposure environment and architectural specification.

Color and Gloss Retention

For exterior facades, coating qualification should consider long-term color change, chalking and gloss retention rather than relying on a general claim of “no fading.”

HDP and PE Coating Options

High Durable Polyester

HDP can be considered for architectural applications requiring a higher durability level than standard polyester while balancing cost and exterior performance.

Standard PE Polyester

PE polyester is an economical option for general building components and less demanding exposure conditions. Exterior use should be matched to the specific polyester formulation and required appearance-retention period.

Coating Selection for Ecuador Projects

Ecuador includes a range of building environments, and coating selection should reflect the actual project location rather than use one specification for every region.

Strong Solar Exposure

Facade projects with intensive solar exposure should prioritize UV resistance, color retention, chalk resistance and stable pigment systems.

Coastal Environments

Projects near the coast require additional attention to pretreatment, primer performance, coating integrity, cut edges, fasteners, joints and maintenance because airborne salts can increase corrosion risk.

High Humidity

Where condensation or persistent humidity is expected, panel joints, reverse-side protection, drainage and ventilation should be designed so that trapped moisture does not remain against the metal surface.

Project-Specific Exposure

Building elevation, distance from the coast, industrial pollution, cleaning frequency and orientation can all influence coating selection and maintenance planning.

Discuss Your Ecuador Project Environment

Facade cladding project environmental and wind direction consideration

Facade Color Consistency

Large building elevations can use material from multiple coils and production batches, so color and gloss consistency should be controlled before installation.

Physical Master Sample

A physical approved color sample is recommended for each facade project and should be retained throughout production.

Instrumental Color Control

Where ΔE limits are specified, the color standard, measuring instrument, illuminant, observation angle and calculation method should be defined.

Gloss Control

Matte, satin and glossy descriptions should be supplemented with a measurable gloss target where adjacent-panel appearance is critical.

Metallic Color Orientation

Metallic and effect colors can show directional differences. Sheets should be cut and installed with consistent rolling and coating direction to reduce visible shade variation.

Continuous Coil Coating

Prepainted aluminum is coated in a continuous factory process before being cut and fabricated into facade components.

Cleaning and Pretreatment

The aluminum surface is cleaned and chemically pretreated to support coating adhesion and corrosion resistance.

Primer Application

Primer provides an intermediate layer between the pretreated aluminum and the decorative topcoat.

Top-Coat Application

The available top-paint thickness is 25–28μm. The total coating structure should be agreed according to PVDF, HDP or PE system requirements.

Back Coating

A 5–8μm back coat is available to provide reverse-side protection according to the panel manufacturing process.

Post-Forming and Panel Fabrication

The selected aluminum alloy, temper and coating must withstand the intended panel manufacturing sequence.

Cutting

Sheets can be cut to panel blanks according to architectural drawings. Edges should be controlled for burrs, dents and coating damage.

Bending and Folding

Bend radius should be matched to the alloy, temper, 0.8mm gauge and coating flexibility. Tight folds should be validated through a forming trial.

Grooving

Where panels are grooved before folding, groove depth should leave sufficient aluminum thickness for the approved panel construction.

Punching and Perforation

Perforated or decorative panels should be checked for distortion, edge quality and coating condition around punched features.

Protective Film

A peelable protective film can be applied where necessary to reduce scratching during cutting, forming, transportation and installation.

Coating Flexibility and T-Bend

Post-forming performance is especially important when prepainted aluminum is bent after coating.

T-Bend Test

A T-bend test can be included in the coating specification to evaluate coating flexibility and adhesion after folding.

Cross-Hatch Adhesion

Cross-hatch testing can be used to evaluate coating adhesion to the pretreated aluminum substrate before and, where appropriate, after forming.

Forming Trial

A representative fabrication trial is recommended for new alloy-temper combinations, colors, coating systems or complex panel geometries.

Test

Purpose

Dry Film Thickness

Verify primer, topcoat and back-coat film build

Color Difference

Control batch-to-batch color variation

Gloss

Control visual consistency across the elevation

Cross-Hatch Adhesion

Evaluate coating adhesion

T-Bend

Evaluate coating flexibility during post-forming

Impact Resistance

Evaluate coating integrity under deformation

Pencil Hardness

Provide a comparative coating-hardness value

Solvent Rub / Cure Test

Evaluate coating cure where applicable

Salt Spray

Comparative corrosion testing under defined conditions

Humidity Resistance

Evaluate coating response to prolonged moisture exposure

Accelerated Weathering

Compare color, gloss and chalking performance

AAMA 2605 and Architectural PVDF

For demanding exterior architectural projects, coating specifications may require performance consistent with AAMA 2605-type criteria.

Such requirements should be applied to the actual coating system rather than simply describing the aluminum sheet as “AAMA compliant.”

Coating Resin

Where specified, high-performance architectural systems can use a fluoropolymer color coat based on at least 70% PVDF resin.

Weathering Tests

Architectural coating qualification can include color retention, chalking, gloss retention, humidity and corrosion testing according to the required specification.

Coil vs Extrusion Coatings

This product is factory coil coated before panel fabrication. Coatings applied to aluminum extrusions use a different application process and should not be treated as the same product specification.

EN 1396 Coil-Coated Aluminum

EN 1396 covers coil-coated wrought aluminum and aluminum-alloy sheet and strip for general applications and can be used as a material reference where required by the project specification.

The purchase specification should still define alloy, temper, gauge, coating, color, gloss, protective film and any additional architectural performance requirements.

Salt-Spray Testing and Coastal Projects

Salt-spray testing can help compare corrosion resistance of coating systems under controlled laboratory conditions.

A salt-spray result should not be converted directly into a fixed number of outdoor service years.

Cut Edges

Cut and drilled edges can expose bare aluminum. Edge design, drainage and maintenance should minimize prolonged accumulation of salty moisture.

Fastener Compatibility

Fasteners and brackets should be selected to reduce galvanic-corrosion risk where dissimilar metals are present.

Routine Cleaning

Coastal facades may benefit from project-appropriate cleaning to remove accumulated salts, dirt and pollutants from coated surfaces.

Coating Warranty and Service Life

A universal “20-year no-fade” claim should not be applied to every facade project.

Warranty availability and coating performance depend on the coating supplier, resin system, pigment, color, building location, orientation, marine exposure, fabrication, installation and maintenance.

Where a formal coating warranty is required, the exact color, paint system and Ecuador project location should be submitted for coating-supplier review before production.

Complete Facade System Performance

The 0.8mm coated aluminum sheet is a facade skin material. Performance of the installed building envelope depends on the complete assembly.

Performance Item

Depends On

Wind Resistance

Panel dimensions, skin gauge, stiffeners, brackets, anchors and substructure

Water Tightness

Panel joints, flashings, drainage, sealants and cavity design

Air Leakage

Complete curtain-wall or rainscreen sealing system

Thermal Performance

Insulation, cavities, thermal bridges and wall construction

Fire Performance

Panel skin, coatings, insulation, cavity barriers, fixings and complete tested assembly

Structural Movement

Joint design, fixings and accommodation of thermal/building movement

Main Applications

Exterior Facade Cladding

0.8mm prepainted aluminum can be fabricated into compatible wall-cladding skins for commercial, residential and public buildings.

Curtain Wall Panel Skins

The sheet can be used as a skin material in appropriately engineered curtain-wall or cassette-panel constructions.

Soffits and Canopies

Lightweight coated aluminum can be used for compatible soffit, canopy and fascia components requiring a factory-finished architectural surface.

Commercial and Public Buildings

Applications include compatible architectural cladding for shopping centers, airports, transport facilities, offices, industrial buildings and other facade projects.

Quality Control

Inspection Item

Recommended Control

Alloy & Temper

Verify against approved project specification

Metal Thickness

Verify 0.8mm or approved custom gauge and tolerance

Sheet Width

Verify finished width against fabrication drawing

Coating System

Verify PVDF / HDP / PE and approved paint construction

Top-Coat Thickness

Verify 25–28μm where specified

Back-Coat Thickness

Verify 5–8μm where specified

Color

Compare with approved physical master and instrumental data

Gloss

Verify against approved numerical target where specified

Coating Adhesion

Test by agreed cross-hatch or other method

T-Bend

Verify coating flexibility where sheet will be post-formed

Surface Appearance

Inspect scratches, dents, roller marks, streaks and coating defects

Flatness

Inspect sheet shape before panel fabrication

Protective Film

Verify type, adhesion and removal requirement where supplied

Sample and First-Piece Approval

A physical sample should be approved before bulk production whenever a new color, gloss level, alloy, temper or coating system is introduced.

For metallic or effect finishes, review the sample in representative daylight and confirm panel orientation before final approval.

A fabrication trial should also be completed using the actual cutting, grooving, bending and punching processes planned by the panel manufacturer.

After approval, retain the master color sample, gloss target, coating construction, alloy-temper specification and fabrication settings for repeat orders.

Request Color & Fabrication Samples

Packaging and Shipping to Ecuador

Facade sheets should be packed to protect the coated surface, sheet edges and flatness during long-distance transportation.

Protective Film

Peelable protective film can be applied to the decorated surface to reduce scratching during loading, transportation, cutting and fabrication.

Moisture Protection

Export packaging should limit rain and condensation exposure during storage and sea transportation.

Rigid Export Support

Sheets can be packed on suitable export pallets or other rigid supports to reduce movement and deformation during handling.

Container Loading

Pallet dimensions, total weight and stacking method should be planned according to sheet dimensions and container-loading requirements.

Information Required for a Quotation

Please provide the facade application, building location in Ecuador, coastal or inland environment, panel dimensions and required metal thickness.

Specify the required alloy and temper, or provide the panel fabrication method so a suitable combination can be discussed.

Provide the coating system, including PVDF, HDP or PE, together with any required resin content, top-coat thickness and back-coat specification.

Provide the RAL, Pantone or physical color sample, required gloss and any metallic or special-effect finish.

For fabrication, identify bend radius, grooving, perforation, punching and protective-film requirements.

Where project standards are specified, provide the applicable EN, ASTM, AAMA or project-specific coating test requirements.

Send Your Ecuador Facade Specification

FAQ

What is 0.8mm color coated aluminum facade sheet?

It is prepainted aluminum sheet supplied for further fabrication into compatible exterior cladding, facade skins, soffits, canopies and curtain-wall components.

Which alloys are available?

Available alloy options include AA3003, AA3004, AA3105 and AA5052.

Why are different alloys offered?

Different alloys provide different combinations of strength, stiffness and formability. The correct selection depends on panel size, bend geometry and system design.

Is 0.8mm thick enough for every curtain-wall panel?

No. The required skin thickness depends on panel dimensions, stiffeners, wind load, fixings and complete facade engineering.

Can thicker or thinner sheet be supplied?

The available range includes 0.4–1.2mm for compatible applications, subject to alloy and project requirements.

Which widths are available?

Standard listed widths include 1000mm, 1220mm, 1250mm and 1500mm, with custom dimensions available for discussion.

Which coating is best for an exterior facade in Ecuador?

For demanding exterior exposure, a properly specified architectural PVDF system is generally preferred. The exact choice should reflect UV exposure, coastal conditions, color and project warranty requirements.

Is 70% PVDF available?

A 70% PVDF resin requirement can be specified where the project calls for a high-performance architectural fluoropolymer system, subject to coating-system confirmation.

What is the difference between PVDF and HDP?

PVDF is generally selected for higher exterior weathering requirements. HDP is a durable polyester option that can provide a balance between performance and cost for suitable applications.

Can PE polyester be used outdoors?

PE can be used in suitable applications, but performance depends on the specific polyester grade, color, UV exposure and expected appearance-retention requirements.

Does PVDF guarantee 20 years without fading?

No universal no-fade period applies to every project. Coating warranty and performance depend on the exact paint system, color, location, exposure, fabrication and maintenance.

Is this sheet suitable for Guayaquil or other coastal areas?

It can be specified for coastal facade projects when the coating, pretreatment, exposed edges, fasteners, joints and maintenance plan are selected for the actual marine exposure.

Does salt-spray testing predict exact service life?

No. Salt-spray testing is a comparative laboratory test and should not be directly converted into years of outdoor service.

Can the sheet be bent after coating?

Yes, provided the alloy, temper, bend radius and coating flexibility are compatible. A forming trial is recommended before bulk fabrication.

Can it be perforated?

Yes. Perforation can be carried out where the selected alloy, gauge and panel design support the required pattern and open area.

What is T-bend testing?

T-bend testing evaluates how the coating behaves when prepainted metal is folded and is useful for post-formed facade materials.

Can custom RAL colors be supplied?

Yes. RAL, Pantone and customer physical samples can be used for compatible custom color development.

How should metallic colors be installed?

Metallic finishes should normally maintain consistent sheet and coating direction across adjacent facade panels to reduce visible directional shade differences.

Is protective film available?

Protective film can be supplied for compatible products to reduce surface damage during fabrication, transportation and installation.

Is the aluminum sheet itself fire-rated?

Aluminum metal is non-combustible, but the fire classification of a coated facade or curtain-wall construction must be based on the actual tested material or complete assembly.

Does 0.8mm aluminum provide building insulation?

No. Aluminum is highly thermally conductive. Building thermal performance comes primarily from insulation, cavities, thermal breaks and the complete facade build-up.

Is EN 1396 applicable?

EN 1396 can be relevant to coil-coated aluminum sheet and strip for general applications. Any project-specific requirements should be added separately.

Can samples be supplied before production?

Samples can be discussed for color, gloss, coating appearance and fabrication evaluation before bulk production.

What information is required for a quotation?

Please provide project location, alloy, temper, thickness, width, coating system, color, gloss, panel dimensions, fabrication method, protective-film requirement and order quantity.

Request a Quote for 0.8mm Aluminum Facade Sheet for Ecuador

If you are sourcing material for facade cladding, curtain-wall skins, soffits, canopies or other architectural panels in Ecuador, send us your project environment, dimensions and coating requirements.

Available options include AA3003, AA3004, AA3105 and AA5052 substrates, 0.8mm standard thickness, PVDF/HDP/PE coatings, custom colors and project-specific protective film.

Request a Quotation

Previous: 
Next: 

Product Category

Consult Us To Get Your Customized Aluminum Solution

We help you specify and source the coated aluminum you need, on time and within budget.

Products

Application

Quick links

Follow Us

Contact Us

    joey@cnchangsong.com
    +86-18602595888
   Building 2, Zhixing Business Plaza, No.25 North Street, Zhonglou District, Changzhou City, Jiangsu Province, China
    Chaoyang road, Konggang economic development area, Lianshui, Huai'an city, Jiangsu,China
© COPYRIGHT 2026 CHANGZHOU DINGANG METAL MATERIAL CO., LTD. ALL RIGHTS RESERVED.