| Availability: | |
|---|---|
| Quantity: | |
0.8mm color coated aluminum facade sheet is designed for architectural cladding, curtain-wall skins, soffits, canopies, fascia and other non-structural exterior metal components used in commercial, residential and public building projects.
Available substrate alloys include AA3003, AA3004, AA3105 and AA5052, with alloy and temper selected according to panel size, forming severity, required stiffness and fabrication method. The standard product thickness is 0.8mm, with additional gauges from 0.4mm to 1.2mm available for compatible applications.
PVDF, high-durable polyester (HDP) and PE coating systems are available. For demanding exterior facade projects in Ecuador, especially coastal or high-UV environments, the exact coating resin, pretreatment, primer, topcoat, color pigments and exposed-edge design should be selected according to project conditions.
The aluminum sheet is supplied as material for further facade-panel fabrication. Wind resistance, water tightness, fire performance, fixing capacity and structural safety must be engineered and verified for the complete cladding or curtain-wall system.
Request Ecuador Facade Sheet Pricing
Property | Available Specification | Project Notes |
Product | Prepainted Aluminum Facade Cladding Sheet | For architectural cladding and curtain-wall panel fabrication |
Alloys | AA3003 / AA3004 / AA3105 / AA5052 | Select alloy according to forming, stiffness and panel design |
Temper | H14 / H24 / H16 / H26 according to alloy and project | Final alloy-temper combination should be confirmed before production |
Standard Thickness | 0.8mm | Facade skin thickness; structural adequacy depends on the complete panel system |
Custom Thickness | 0.4–1.2mm | Subject to panel geometry and production requirements |
Widths | 1000 / 1220 / 1250 / 1500mm | Custom widths can be discussed |
Coating Systems | PVDF / HDP / PE | Select according to exterior exposure and performance requirement |
Top-Coat Thickness | 25–28μm | Confirm total coating construction for the selected paint system |
Back-Coat Thickness | 5–8μm | Back coating can be matched to panel fabrication requirements |
PVDF Resin Requirement | Project-specific | Specify 70% PVDF where required by the architectural coating specification |
Colors | RAL / Pantone / Physical Sample / Custom | Physical master sample recommended for facade projects |
Gloss | Matte / Satin / Semi-Gloss / High Gloss | Numerical gloss target recommended for large elevations |
Metallic / Effect Colors | Available according to coating system | Panel orientation should remain consistent during installation |
Protective Film | Optional | Recommended for appearance-critical panel fabrication |
Supply Form | Sheet / Coil / Slit Coil according to order | Match fabricator equipment and panel dimensions |
Applications | Facade / Curtain Wall / Soffit / Canopy / Fascia / Siding | Non-structural skin material unless engineered otherwise |
The appropriate aluminum alloy depends on panel geometry, forming requirements, sheet size and required mechanical strength.
AA3003 is an Al-Mn alloy widely used for architectural and general sheet fabrication because it combines moderate strength, corrosion resistance and good formability.
AA3004 provides higher strength than commercially pure aluminum and can be considered for compatible facade profiles requiring additional stiffness while retaining useful forming capability.
AA3105 is commonly used in coated architectural sheet, siding and building components where formability and corrosion resistance are important.
AA5052 provides higher strength and strong corrosion resistance and can be evaluated for more demanding fabricated components. The selected temper and bend geometry should be confirmed before production.
A 0.8mm gauge offers a lightweight metal skin for compatible facade and cladding designs while remaining suitable for cutting, bending, profiling and other sheet-fabrication processes.
However, 0.8mm thickness should not be treated as a universal structural specification for every curtain-wall panel.
Larger panels can experience greater deflection than smaller panels. Panel width, height, edge returns and intermediate stiffeners should therefore be considered together with skin thickness.
Resistance to wind pressure and suction depends on the aluminum skin, panel geometry, stiffeners, fasteners, brackets and supporting substructure.
Grooving depth, bend radius, perforations and panel cut-outs can affect the remaining section strength and should follow the approved panel drawing.
PVDF fluoropolymer coatings are commonly selected for architectural metal exposed to demanding sunlight and weathering conditions.
Where the project specification calls for a high-performance architectural fluoropolymer coating, the purchase requirement should identify the required PVDF resin content, coating manufacturer and applicable performance standard.
A statement such as “PVDF coated” alone is not sufficient to define coating durability because different PVDF formulations and coating constructions can have different performance levels.
A typical two-coat system includes primer and color topcoat. Three-coat constructions can include primer, color coat and clear coat or another approved finishing layer.
The appropriate system depends on color, metallic effects, exposure environment and architectural specification.
For exterior facades, coating qualification should consider long-term color change, chalking and gloss retention rather than relying on a general claim of “no fading.”
HDP can be considered for architectural applications requiring a higher durability level than standard polyester while balancing cost and exterior performance.
PE polyester is an economical option for general building components and less demanding exposure conditions. Exterior use should be matched to the specific polyester formulation and required appearance-retention period.
Ecuador includes a range of building environments, and coating selection should reflect the actual project location rather than use one specification for every region.
Facade projects with intensive solar exposure should prioritize UV resistance, color retention, chalk resistance and stable pigment systems.
Projects near the coast require additional attention to pretreatment, primer performance, coating integrity, cut edges, fasteners, joints and maintenance because airborne salts can increase corrosion risk.
Where condensation or persistent humidity is expected, panel joints, reverse-side protection, drainage and ventilation should be designed so that trapped moisture does not remain against the metal surface.
Building elevation, distance from the coast, industrial pollution, cleaning frequency and orientation can all influence coating selection and maintenance planning.
Discuss Your Ecuador Project Environment
Large building elevations can use material from multiple coils and production batches, so color and gloss consistency should be controlled before installation.
A physical approved color sample is recommended for each facade project and should be retained throughout production.
Where ΔE limits are specified, the color standard, measuring instrument, illuminant, observation angle and calculation method should be defined.
Matte, satin and glossy descriptions should be supplemented with a measurable gloss target where adjacent-panel appearance is critical.
Metallic and effect colors can show directional differences. Sheets should be cut and installed with consistent rolling and coating direction to reduce visible shade variation.
Prepainted aluminum is coated in a continuous factory process before being cut and fabricated into facade components.
The aluminum surface is cleaned and chemically pretreated to support coating adhesion and corrosion resistance.
Primer provides an intermediate layer between the pretreated aluminum and the decorative topcoat.
The available top-paint thickness is 25–28μm. The total coating structure should be agreed according to PVDF, HDP or PE system requirements.
A 5–8μm back coat is available to provide reverse-side protection according to the panel manufacturing process.
The selected aluminum alloy, temper and coating must withstand the intended panel manufacturing sequence.
Sheets can be cut to panel blanks according to architectural drawings. Edges should be controlled for burrs, dents and coating damage.
Bend radius should be matched to the alloy, temper, 0.8mm gauge and coating flexibility. Tight folds should be validated through a forming trial.
Where panels are grooved before folding, groove depth should leave sufficient aluminum thickness for the approved panel construction.
Perforated or decorative panels should be checked for distortion, edge quality and coating condition around punched features.
A peelable protective film can be applied where necessary to reduce scratching during cutting, forming, transportation and installation.
Post-forming performance is especially important when prepainted aluminum is bent after coating.
A T-bend test can be included in the coating specification to evaluate coating flexibility and adhesion after folding.
Cross-hatch testing can be used to evaluate coating adhesion to the pretreated aluminum substrate before and, where appropriate, after forming.
A representative fabrication trial is recommended for new alloy-temper combinations, colors, coating systems or complex panel geometries.
Test | Purpose |
Dry Film Thickness | Verify primer, topcoat and back-coat film build |
Color Difference | Control batch-to-batch color variation |
Gloss | Control visual consistency across the elevation |
Cross-Hatch Adhesion | Evaluate coating adhesion |
T-Bend | Evaluate coating flexibility during post-forming |
Impact Resistance | Evaluate coating integrity under deformation |
Pencil Hardness | Provide a comparative coating-hardness value |
Solvent Rub / Cure Test | Evaluate coating cure where applicable |
Salt Spray | Comparative corrosion testing under defined conditions |
Humidity Resistance | Evaluate coating response to prolonged moisture exposure |
Accelerated Weathering | Compare color, gloss and chalking performance |
For demanding exterior architectural projects, coating specifications may require performance consistent with AAMA 2605-type criteria.
Such requirements should be applied to the actual coating system rather than simply describing the aluminum sheet as “AAMA compliant.”
Where specified, high-performance architectural systems can use a fluoropolymer color coat based on at least 70% PVDF resin.
Architectural coating qualification can include color retention, chalking, gloss retention, humidity and corrosion testing according to the required specification.
This product is factory coil coated before panel fabrication. Coatings applied to aluminum extrusions use a different application process and should not be treated as the same product specification.
EN 1396 covers coil-coated wrought aluminum and aluminum-alloy sheet and strip for general applications and can be used as a material reference where required by the project specification.
The purchase specification should still define alloy, temper, gauge, coating, color, gloss, protective film and any additional architectural performance requirements.
Salt-spray testing can help compare corrosion resistance of coating systems under controlled laboratory conditions.
A salt-spray result should not be converted directly into a fixed number of outdoor service years.
Cut and drilled edges can expose bare aluminum. Edge design, drainage and maintenance should minimize prolonged accumulation of salty moisture.
Fasteners and brackets should be selected to reduce galvanic-corrosion risk where dissimilar metals are present.
Coastal facades may benefit from project-appropriate cleaning to remove accumulated salts, dirt and pollutants from coated surfaces.
A universal “20-year no-fade” claim should not be applied to every facade project.
Warranty availability and coating performance depend on the coating supplier, resin system, pigment, color, building location, orientation, marine exposure, fabrication, installation and maintenance.
Where a formal coating warranty is required, the exact color, paint system and Ecuador project location should be submitted for coating-supplier review before production.
The 0.8mm coated aluminum sheet is a facade skin material. Performance of the installed building envelope depends on the complete assembly.
Performance Item | Depends On |
Wind Resistance | Panel dimensions, skin gauge, stiffeners, brackets, anchors and substructure |
Water Tightness | Panel joints, flashings, drainage, sealants and cavity design |
Air Leakage | Complete curtain-wall or rainscreen sealing system |
Thermal Performance | Insulation, cavities, thermal bridges and wall construction |
Fire Performance | Panel skin, coatings, insulation, cavity barriers, fixings and complete tested assembly |
Structural Movement | Joint design, fixings and accommodation of thermal/building movement |
0.8mm prepainted aluminum can be fabricated into compatible wall-cladding skins for commercial, residential and public buildings.
The sheet can be used as a skin material in appropriately engineered curtain-wall or cassette-panel constructions.
Lightweight coated aluminum can be used for compatible soffit, canopy and fascia components requiring a factory-finished architectural surface.
Applications include compatible architectural cladding for shopping centers, airports, transport facilities, offices, industrial buildings and other facade projects.
Inspection Item | Recommended Control |
Alloy & Temper | Verify against approved project specification |
Metal Thickness | Verify 0.8mm or approved custom gauge and tolerance |
Sheet Width | Verify finished width against fabrication drawing |
Coating System | Verify PVDF / HDP / PE and approved paint construction |
Top-Coat Thickness | Verify 25–28μm where specified |
Back-Coat Thickness | Verify 5–8μm where specified |
Color | Compare with approved physical master and instrumental data |
Gloss | Verify against approved numerical target where specified |
Coating Adhesion | Test by agreed cross-hatch or other method |
T-Bend | Verify coating flexibility where sheet will be post-formed |
Surface Appearance | Inspect scratches, dents, roller marks, streaks and coating defects |
Flatness | Inspect sheet shape before panel fabrication |
Protective Film | Verify type, adhesion and removal requirement where supplied |
A physical sample should be approved before bulk production whenever a new color, gloss level, alloy, temper or coating system is introduced.
For metallic or effect finishes, review the sample in representative daylight and confirm panel orientation before final approval.
A fabrication trial should also be completed using the actual cutting, grooving, bending and punching processes planned by the panel manufacturer.
After approval, retain the master color sample, gloss target, coating construction, alloy-temper specification and fabrication settings for repeat orders.
Request Color & Fabrication Samples
Facade sheets should be packed to protect the coated surface, sheet edges and flatness during long-distance transportation.
Peelable protective film can be applied to the decorated surface to reduce scratching during loading, transportation, cutting and fabrication.
Export packaging should limit rain and condensation exposure during storage and sea transportation.
Sheets can be packed on suitable export pallets or other rigid supports to reduce movement and deformation during handling.
Pallet dimensions, total weight and stacking method should be planned according to sheet dimensions and container-loading requirements.
Please provide the facade application, building location in Ecuador, coastal or inland environment, panel dimensions and required metal thickness.
Specify the required alloy and temper, or provide the panel fabrication method so a suitable combination can be discussed.
Provide the coating system, including PVDF, HDP or PE, together with any required resin content, top-coat thickness and back-coat specification.
Provide the RAL, Pantone or physical color sample, required gloss and any metallic or special-effect finish.
For fabrication, identify bend radius, grooving, perforation, punching and protective-film requirements.
Where project standards are specified, provide the applicable EN, ASTM, AAMA or project-specific coating test requirements.
Send Your Ecuador Facade Specification
It is prepainted aluminum sheet supplied for further fabrication into compatible exterior cladding, facade skins, soffits, canopies and curtain-wall components.
Available alloy options include AA3003, AA3004, AA3105 and AA5052.
Different alloys provide different combinations of strength, stiffness and formability. The correct selection depends on panel size, bend geometry and system design.
No. The required skin thickness depends on panel dimensions, stiffeners, wind load, fixings and complete facade engineering.
The available range includes 0.4–1.2mm for compatible applications, subject to alloy and project requirements.
Standard listed widths include 1000mm, 1220mm, 1250mm and 1500mm, with custom dimensions available for discussion.
For demanding exterior exposure, a properly specified architectural PVDF system is generally preferred. The exact choice should reflect UV exposure, coastal conditions, color and project warranty requirements.
A 70% PVDF resin requirement can be specified where the project calls for a high-performance architectural fluoropolymer system, subject to coating-system confirmation.
PVDF is generally selected for higher exterior weathering requirements. HDP is a durable polyester option that can provide a balance between performance and cost for suitable applications.
PE can be used in suitable applications, but performance depends on the specific polyester grade, color, UV exposure and expected appearance-retention requirements.
No universal no-fade period applies to every project. Coating warranty and performance depend on the exact paint system, color, location, exposure, fabrication and maintenance.
It can be specified for coastal facade projects when the coating, pretreatment, exposed edges, fasteners, joints and maintenance plan are selected for the actual marine exposure.
No. Salt-spray testing is a comparative laboratory test and should not be directly converted into years of outdoor service.
Yes, provided the alloy, temper, bend radius and coating flexibility are compatible. A forming trial is recommended before bulk fabrication.
Yes. Perforation can be carried out where the selected alloy, gauge and panel design support the required pattern and open area.
T-bend testing evaluates how the coating behaves when prepainted metal is folded and is useful for post-formed facade materials.
Yes. RAL, Pantone and customer physical samples can be used for compatible custom color development.
Metallic finishes should normally maintain consistent sheet and coating direction across adjacent facade panels to reduce visible directional shade differences.
Protective film can be supplied for compatible products to reduce surface damage during fabrication, transportation and installation.
Aluminum metal is non-combustible, but the fire classification of a coated facade or curtain-wall construction must be based on the actual tested material or complete assembly.
No. Aluminum is highly thermally conductive. Building thermal performance comes primarily from insulation, cavities, thermal breaks and the complete facade build-up.
EN 1396 can be relevant to coil-coated aluminum sheet and strip for general applications. Any project-specific requirements should be added separately.
Samples can be discussed for color, gloss, coating appearance and fabrication evaluation before bulk production.
Please provide project location, alloy, temper, thickness, width, coating system, color, gloss, panel dimensions, fabrication method, protective-film requirement and order quantity.
If you are sourcing material for facade cladding, curtain-wall skins, soffits, canopies or other architectural panels in Ecuador, send us your project environment, dimensions and coating requirements.
Available options include AA3003, AA3004, AA3105 and AA5052 substrates, 0.8mm standard thickness, PVDF/HDP/PE coatings, custom colors and project-specific protective film.
Products
Application
Quick links
Contact Us