| Availability: | |
|---|---|
| Quantity: | |
1050 solid aluminum cladding panel is a single-skin architectural metal panel fabricated from aluminum sheet for exterior curtain walls, ventilated facades, column covers, soffits, entrances, canopies and other architectural cladding applications.
The 1050 aluminum substrate contains a minimum of approximately 99.5% aluminum and provides good cold-forming capability for compatible cutting, folding, flanging, curving, punching and custom panel fabrication.
Published panel thicknesses include 1.5mm, 2.0mm, 2.5mm, 3.0mm and 4.0mm, with custom fabricated panel sizes up to 1500mm × 6000mm. PVDF fluorocarbon coating, custom RAL colors, metallic finishes and project-specific panel geometries are available according to approved drawings and samples.
Request a Facade Panel Quotation
Item | Published / Available Specification | Project Consideration |
|---|---|---|
Product Type | Solid aluminum cladding / facade cassette panel | For curtain wall, rainscreen and architectural wall applications |
Base Material | 1050 aluminum, Al ≥99.5% | Panel structural design should reflect the mechanical properties of the selected alloy and temper |
Panel Thickness | 1.5mm / 2.0mm / 2.5mm / 3.0mm / 4.0mm | Select according to panel dimensions, wind pressure, stiffeners and support spacing |
Maximum Published Panel Size | 1500mm × 6000mm | Large panels require engineering review for flatness, deflection, handling and stiffening |
Panel Geometry | Flat / curved / perforated / folded / custom shape | Fabrication follows approved CAD or shop drawings |
Coating Type | PVDF fluorocarbon coating | Confirm coating manufacturer, system construction and required performance standard |
Kynar 500 Reference | 70% Kynar 500 PVDF resin system published | Where specified, verify licensed formulation and PVDF resin content based on total binder weight |
Published Coating Thickness | 28μm–40μm primer + topcoat | Confirm number of coats, dry-film measurement method and acceptance range |
Surface Finish | Matte / medium gloss / high gloss / metallic / brushed / mirror | Finish availability depends on the approved coating or decorative surface system |
Colors | RAL references / custom colors | Physical sample approval recommended before project production |
Published Flatness Reference | ≤0.5mm/m | Confirm panel size, measurement method and support condition where contract-critical |
Published Dimensional Reference | ±0.1mm | Final fabrication tolerances should follow drawing dimensions and measurement method |
Installation | Hidden bracket / open-frame systems | Fixing layout and subframe should follow project structural calculations |
Fire Performance | Solid aluminum substrate; project-specific classification to be confirmed | Request the applicable test report for the finished panel and facade assembly |
Final panel thickness, return depth, stiffener design, fixing layout, joint width and subframe spacing should be determined from the approved architectural drawings and project structural requirements rather than from panel thickness alone.
Get Panel Specifications & Pricing
1050 belongs to the commercially pure 1xxx-series aluminum family and contains at least approximately 99.5% aluminum. It provides useful corrosion resistance and cold-forming capability for suitable architectural sheet-metal fabrication.
The alloy can be CNC cut, folded, flanged and fabricated into compatible cassette, curved and special-shaped panels.
Because 1050 has lower strength than common 3xxx- or 5xxx-series architectural aluminum alloys, large panels or high-wind applications should be engineered using appropriate thickness, edge returns, stiffeners and fixing layouts.
Panel Thickness | General Selection Direction |
|---|---|
1.5mm | Interior cladding, ceilings and smaller decorative components where engineering requirements permit |
2.0mm | Smaller exterior or interior panels subject to project review |
2.5mm | Common facade-panel thickness range where panel dimensions and wind-load calculations permit |
3.0mm | Widely used for exterior cassette and rainscreen panels requiring additional rigidity |
4.0mm | Heavy-gauge option for selected large-format or demanding fabricated components |
These are selection directions rather than structural design rules. Final thickness should be verified using the panel geometry, alloy and temper, wind pressure, support spacing, stiffener layout, deflection limits and applicable building requirements.
PVDF architectural coating is used on exterior aluminum facades where resistance to UV exposure, weathering, color change, chalking and environmental degradation is important.
Where Kynar 500 is specified, the coating should be sourced from an appropriate licensed formulation. The published 70% reference relates to the proportion of Kynar 500 PVDF resin within the coating binder rather than 70% of the total dry paint film.
The current published coating range is 28μm to 40μm for the primer and top-finish construction. Final dry-film thickness, number of coats and measurement method should be stated in the project specification.
Where AAMA 2605 performance is required, buyers should state this in the order specification and request documentation applicable to the selected coating system and applicator.
AAMA 2605 addresses demanding architectural coating performance, including weathering, color retention, chalk resistance, adhesion and other coating properties. Compliance should be supported by applicable product or coating documentation rather than assumed from the term PVDF alone.
Performance Item | Project Information to Confirm |
|---|---|
Dry Film Thickness | Primer, topcoat, optional clearcoat and total dry-film requirement |
Adhesion | Applicable adhesion test and acceptance requirement |
Color Difference | Approved master sample and permitted color tolerance |
Gloss | Target gloss level, measuring angle and tolerance |
Weathering | Required architectural coating specification and exposure performance |
Salt / Corrosion Exposure | Test standard and environmental requirement for coastal or industrial projects |
Chemical Resistance | Project-specific pollutants or cleaning agents where applicable |
A solid aluminum facade panel is commonly fabricated from a single aluminum sheet that is CNC cut and folded to form a cassette with perimeter returns.
Folded edges increase local panel stiffness and provide attachment zones for brackets, hooks or other fixing components. Return depth should follow the approved panel and installation drawings.
Cassette corners can be mechanically connected or welded according to the panel geometry and approved fabrication procedure.
Large panels may require aluminum stiffeners or other engineered reinforcement on the rear side to control deflection, oil-canning and wind-pressure response.
Stiffener section, spacing and attachment method should be determined from structural calculations rather than using one universal spacing for all panels.
Flat cassette panels can be manufactured according to facade setting-out drawings and panel schedules for conventional curtain-wall and rainscreen elevations.
Curved aluminum panels can be fabricated for columns, entrance features, canopies and curved facade surfaces where forming radius, panel dimensions and surface appearance are confirmed in advance.
CNC punching or cutting can be used for project-specific perforation patterns. Hole dimensions, open area, edge distance and structural effect should be reviewed before production.
Triangular, trapezoidal, folded, faceted and other architectural panels can be evaluated according to CAD or shop drawings and fabrication feasibility.
Solid aluminum panels can be used as the exterior rainscreen or decorative face of compatible curtain-wall and ventilated-facade systems.
The complete wall assembly may include aluminum panels, brackets, rails or keels, insulation, membranes, cavity barriers, sealants, fasteners and structural backing.
Thermal, acoustic, air-infiltration, water-penetration, fire and structural performance should therefore be evaluated at system level where the project requires those properties.
Exterior facade panels are subject to positive and negative wind pressures that vary with building height, location, facade zone and surrounding terrain.
Panel thickness should therefore not be selected solely from a generic rule such as “2.5mm for standard buildings” or “3mm for high-rise buildings.”
Engineering review should consider:
Design wind pressure and suction
Panel width and height
Aluminum alloy and temper
Panel thickness
Edge-return dimensions
Stiffener size and spacing
Bracket and fastener capacity
Subframe spacing
Allowable deflection
Facade corner and edge zones
Aluminum expands and contracts with temperature changes. Large facade elevations and long panels require sufficient joint and fixing tolerance to accommodate thermal movement.
Panel joints, brackets and fixing slots should be detailed so that thermal movement does not create unacceptable panel distortion or stress.
Open-joint systems use defined panel gaps together with an engineered cavity and weather-resistive backing system. Joint dimensions and cavity design should follow the facade system requirements.
Where panel joints are sealed, joint width, backing material, sealant type, adhesion and movement capability should be matched to the expected facade movement.
Concealed cassette systems position the principal panel fixings behind the visible face, supporting a clean facade appearance with no exposed face screws where the approved system permits.
Panels can also be coordinated with aluminum or galvanized-steel rails, keels, brackets and other subframing according to the facade contractor's system design.
Adjustable brackets can help accommodate substrate tolerances and establish the required facade plane, cavity depth and panel alignment.
Aluminum or galvanized-steel subframe components
Adjustable brackets and connectors
Compatible stainless-steel fasteners
Panel hooks or fixing brackets
Isolation pads or separation materials where required
Backing rods and compatible sealants for sealed joints
Rubber or EPDM components where required by the system
Project installation drawings
Sealants, fasteners, membranes and fire-stopping materials should be selected according to the complete facade specification. A product should not be described as fireproof or waterproof solely because it is used with an aluminum panel.
The principal substrate of a solid aluminum panel is a single metal sheet without a combustible polymer core.
However, the fire classification of the finished product or facade assembly can also depend on paint, sealants, insulation, membranes, cavity barriers, backing materials and the applicable national test method.
Where a project specifies Class A, A1, A2-s1,d0 or another classification, the exact standard and corresponding test report for the supplied construction should be confirmed before approval.
Feature | Solid Aluminum Panel | Aluminum Composite Panel |
|---|---|---|
Construction | Single solid aluminum alloy sheet | Aluminum skins bonded to a core |
Core | No composite core | Core type varies by ACP product |
Fabrication | Cutting, folding, welding, curving and stiffening possible | Routing and folding commonly used |
Fire Performance | Metal substrate without polymer core; final classification requires applicable testing | Depends strongly on the composite core and complete tested product |
Repair / Recoating | Single-metal panel can be refinished subject to project requirements | Depends on composite-panel construction and condition |
ACP products are available with different core technologies and fire classifications, so they should not all be treated as having the same fire performance.
Visual flatness depends on material thickness, alloy and temper, panel dimensions, fabrication stresses, edge returns, stiffener layout, coating temperature, support alignment and installation conditions.
The current product information lists a flatness reference of ≤0.5mm/m. Where this is an acceptance requirement, the panel size, measurement method and support condition should be agreed before manufacturing.
Large high-gloss or metallic panels can make small surface waviness more visually apparent, so panel mock-ups are recommended where facade appearance is critical.
RAL references and custom colors can be supplied according to coating-system capability and project quantity.
For metallic, high-gloss and other direction-sensitive finishes, panels should be fabricated and installed with consistent coating orientation to reduce visible variation.
Large facade projects should use approved physical samples and coordinated production batches where practical. Color and gloss acceptance criteria can also be defined for project inspection.
Exterior curtain walls
Ventilated rainscreen facades
High-rise office-building cladding
Shopping-mall facades
Hotel exterior walls
Airport and railway-station facades
Exhibition halls
Hospitals and schools
Stadiums and public buildings
Museum facades
Building entrances and canopies
Column covers
Soffits and fascias
Interior feature walls
Building renovation projects
Curved and special-shaped architectural facades
A typical production route can include 1050 aluminum-sheet inspection, cleaning and pretreatment, primer and PVDF finish application where pre-coated processing is used, curing, CNC cutting, punching, notching, folding, flanging, welding or riveting, stiffener assembly, protective-film application, final inspection and packaging.
Pretreatment chemistry and the sequence of coating and fabrication can vary according to the selected coating line and project specification. Where a specific chromium-free or other pretreatment is required, it should be identified before production.
Custom facade panels should be produced from approved shop drawings or panel schedules rather than architectural elevation dimensions alone.
Typical drawings can identify:
Panel identification number
Finished panel width and height
Panel thickness
Perimeter return dimensions
Corner construction
Stiffener position and spacing
Bracket and hook locations
Joint dimensions
Hole and slot locations
Curvature or bend radius
Coating direction for metallic finishes
Installation position on the elevation
For large or visually critical facade projects, pre-production samples or full-size mock-ups can be used to review color, gloss, panel flatness, joints, corner details, coating orientation and installation appearance.
Where project performance testing is required, representative facade mock-ups can also be evaluated for structural, air or water performance according to the applicable system specification.
Inspection can include aluminum grade and thickness, panel dimensions, diagonals, edge returns, hole locations, flatness, stiffeners, surface appearance, coating thickness, color and gloss according to the approved drawings and inspection plan.
Where coating performance is contract-critical, adhesion, dry-film thickness, color difference and other specified tests can be included with the applicable method and acceptance criteria.
Fire, structural, air or water performance documentation should correspond to the actual material or facade system required by the project rather than being inferred from generic product descriptions.
The coated face can be protected with removable PE film to reduce scratching during fabrication, transportation and installation.
Panels can be separated or wrapped with EPE foam or other protective material, with additional protection at corners and projecting fabricated edges.
Standard panels can be packed on reinforced pallets or in export crates, while curved, oversized or irregular panels can use project-specific supports to reduce deformation during transportation.
Each package can be labeled with panel number, dimensions, thickness, color, elevation or installation location and production batch according to the project packing schedule.
To receive an accurate fabrication review and quotation, please provide as much of the following information as possible:
Architectural elevation or facade drawings
Panel schedule or CAD shop drawings, if available
Required aluminum alloy and temper
Panel thickness
Finished panel dimensions
Flat, curved, perforated or special-shaped construction
Panel edge-return depth
Required stiffener design or structural criteria
Design wind pressure or wind-load requirement
Subframe and fixing-system requirement
Joint width and open-joint or sealed-joint design
PVDF coating specification
Kynar 500 or other specified coating system
Required number of coating layers
Required dry-film thickness
AAMA 2605 or other coating-performance requirement, if applicable
RAL color or approved physical sample
Matte, gloss, metallic or other surface finish
Required fire classification and test standard
Air, water or structural test requirements, if applicable
Fasteners, brackets, rails or other accessories required
Protective-film requirements
Total panel quantity and facade area
Destination country and project location
Delivery port
Required material certificates, coating reports, inspection reports and packing labels
Send Your Facade Panel Drawings
It is an architectural facade panel fabricated from a single solid aluminum alloy sheet rather than aluminum skins bonded to a composite core.
1050 aluminum provides good forming capability and corrosion resistance and can be fabricated into compatible cladding panels. Because its strength differs from commonly used 3003 or 5005 architectural alloys, panel thickness and reinforcement should be reviewed for the project loads.
AA1050 is a commercially pure aluminum grade containing a minimum of approximately 99.5% aluminum.
The current range includes 1.5mm, 2.0mm, 2.5mm, 3.0mm and 4.0mm solid aluminum panels.
No. 2.5mm is a commonly used thickness range for some facade panels, but final selection depends on panel dimensions, alloy, wind pressure, edge returns, stiffeners and fixing layout.
A 3mm panel can provide additional rigidity compared with thinner sheet, but suitability still requires review of the specific panel dimensions, structural loading and reinforcement design.
The current published maximum is 1500mm wide by 6000mm long, subject to fabrication, flatness, structural, transportation and installation review.
Yes. Flat, curved, perforated and other custom fabricated forms can be reviewed according to CAD or shop drawings and production feasibility.
For a licensed Kynar 500 coating formulation, the 70% reference relates to the minimum proportion of Kynar 500 PVDF resin in the total binder system. It does not mean that 70% of the complete dry paint film is fluoropolymer.
The current published coating thickness is 28μm to 40μm for the primer and topcoat system. Final construction should be confirmed with the project coating specification.
No single service-life figure applies to every facade. Performance depends on coating formulation, pigment, pretreatment, film thickness, climate, UV exposure, coastal salt, pollution, panel detailing and maintenance.
Where AAMA 2605 performance is required, it should be specified during quotation so the applicable coating system, formulator and supporting documentation can be confirmed.
The principal substrate is solid metal without a composite polymer core. However, any formal fire classification should correspond to the applicable test standard and the actual finished panel or facade assembly.
Solid aluminum panel uses a single aluminum sheet, while ACP uses aluminum skins bonded to a core. ACP products are available with different core types and fire classifications, so performance should be compared using the actual specified products.
Not necessarily. Stiffener requirements depend on panel dimensions, gauge, alloy, wind pressure, edge returns and allowable deflection. Large panels commonly require additional reinforcement.
Aluminum or galvanized-steel subframe components, brackets, connectors, compatible fasteners and related accessories can be discussed according to the project installation system.
Yes. Concealed bracket, cassette, hook or rail arrangements can be reviewed according to the approved facade system and structural requirements.
Yes. RAL references and project-specific colors can be discussed. Physical coated sample approval is recommended before bulk production.
Direction-sensitive metallic finishes should normally maintain a consistent coating orientation across adjacent facade panels to reduce visible color variation.
Sample and mock-up requirements can be discussed according to panel size, coating, color, fabrication complexity and project approval procedures.
CAD or shop drawings should identify panel dimensions, thickness, edge returns, bends, holes, stiffeners, brackets, joints, finish direction and installation position.
Please provide panel drawings, thickness, dimensions, coating specification, RAL color, wind-load requirements, fixing system, stiffener requirements, fire or performance standards, quantity, project location and destination.
Products
Application
Quick links
Contact Us