1050 Solid Aluminum Cladding Panel PVDF Coated Aluminium Facade Panel for Exterior Curtain Wall
You are here: Home » Brushed Surface » Prepainted Aluminum Coil & Sheet » Color Coated Aluminum Coil » 1050 Solid Aluminum Cladding Panel PVDF Coated Aluminium Facade Panel for Exterior Curtain Wall

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

1050 Solid Aluminum Cladding Panel PVDF Coated Aluminium Facade Panel for Exterior Curtain Wall

1050 solid aluminum cladding panel for exterior curtain walls and facades, available in 1.5-4.0mm thickness with PVDF coating, custom CNC fabrication, RAL colors and project-specific fixing systems.
Availability:
Quantity:

1050 Solid Aluminum Cladding Panel for Exterior Curtain Wall Facades

1050 solid aluminum cladding panel is a single-skin architectural metal panel fabricated from aluminum sheet for exterior curtain walls, ventilated facades, column covers, soffits, entrances, canopies and other architectural cladding applications.

The 1050 aluminum substrate contains a minimum of approximately 99.5% aluminum and provides good cold-forming capability for compatible cutting, folding, flanging, curving, punching and custom panel fabrication.

Published panel thicknesses include 1.5mm, 2.0mm, 2.5mm, 3.0mm and 4.0mm, with custom fabricated panel sizes up to 1500mm × 6000mm. PVDF fluorocarbon coating, custom RAL colors, metallic finishes and project-specific panel geometries are available according to approved drawings and samples.

Request a Facade Panel Quotation

Technical Specifications

Item

Published / Available Specification

Project Consideration

Product Type

Solid aluminum cladding / facade cassette panel

For curtain wall, rainscreen and architectural wall applications

Base Material

1050 aluminum, Al ≥99.5%

Panel structural design should reflect the mechanical properties of the selected alloy and temper

Panel Thickness

1.5mm / 2.0mm / 2.5mm / 3.0mm / 4.0mm

Select according to panel dimensions, wind pressure, stiffeners and support spacing

Maximum Published Panel Size

1500mm × 6000mm

Large panels require engineering review for flatness, deflection, handling and stiffening

Panel Geometry

Flat / curved / perforated / folded / custom shape

Fabrication follows approved CAD or shop drawings

Coating Type

PVDF fluorocarbon coating

Confirm coating manufacturer, system construction and required performance standard

Kynar 500 Reference

70% Kynar 500 PVDF resin system published

Where specified, verify licensed formulation and PVDF resin content based on total binder weight

Published Coating Thickness

28μm–40μm primer + topcoat

Confirm number of coats, dry-film measurement method and acceptance range

Surface Finish

Matte / medium gloss / high gloss / metallic / brushed / mirror

Finish availability depends on the approved coating or decorative surface system

Colors

RAL references / custom colors

Physical sample approval recommended before project production

Published Flatness Reference

≤0.5mm/m

Confirm panel size, measurement method and support condition where contract-critical

Published Dimensional Reference

±0.1mm

Final fabrication tolerances should follow drawing dimensions and measurement method

Installation

Hidden bracket / open-frame systems

Fixing layout and subframe should follow project structural calculations

Fire Performance

Solid aluminum substrate; project-specific classification to be confirmed

Request the applicable test report for the finished panel and facade assembly

Final panel thickness, return depth, stiffener design, fixing layout, joint width and subframe spacing should be determined from the approved architectural drawings and project structural requirements rather than from panel thickness alone.

Get Panel Specifications & Pricing

1050 Aluminum Substrate

1050 belongs to the commercially pure 1xxx-series aluminum family and contains at least approximately 99.5% aluminum. It provides useful corrosion resistance and cold-forming capability for suitable architectural sheet-metal fabrication.

The alloy can be CNC cut, folded, flanged and fabricated into compatible cassette, curved and special-shaped panels.

Because 1050 has lower strength than common 3xxx- or 5xxx-series architectural aluminum alloys, large panels or high-wind applications should be engineered using appropriate thickness, edge returns, stiffeners and fixing layouts.

Panel Thickness Selection

Panel Thickness

General Selection Direction

1.5mm

Interior cladding, ceilings and smaller decorative components where engineering requirements permit

2.0mm

Smaller exterior or interior panels subject to project review

2.5mm

Common facade-panel thickness range where panel dimensions and wind-load calculations permit

3.0mm

Widely used for exterior cassette and rainscreen panels requiring additional rigidity

4.0mm

Heavy-gauge option for selected large-format or demanding fabricated components

These are selection directions rather than structural design rules. Final thickness should be verified using the panel geometry, alloy and temper, wind pressure, support spacing, stiffener layout, deflection limits and applicable building requirements.

PVDF Fluorocarbon Coating

PVDF architectural coating is used on exterior aluminum facades where resistance to UV exposure, weathering, color change, chalking and environmental degradation is important.

70% Kynar 500 PVDF Resin System

Where Kynar 500 is specified, the coating should be sourced from an appropriate licensed formulation. The published 70% reference relates to the proportion of Kynar 500 PVDF resin within the coating binder rather than 70% of the total dry paint film.

28–40μm Coating Thickness

The current published coating range is 28μm to 40μm for the primer and top-finish construction. Final dry-film thickness, number of coats and measurement method should be stated in the project specification.

AAMA 2605 Requirements

Where AAMA 2605 performance is required, buyers should state this in the order specification and request documentation applicable to the selected coating system and applicator.

AAMA 2605 addresses demanding architectural coating performance, including weathering, color retention, chalk resistance, adhesion and other coating properties. Compliance should be supported by applicable product or coating documentation rather than assumed from the term PVDF alone.

PVDF Coating Performance to Specify

Performance Item

Project Information to Confirm

Dry Film Thickness

Primer, topcoat, optional clearcoat and total dry-film requirement

Adhesion

Applicable adhesion test and acceptance requirement

Color Difference

Approved master sample and permitted color tolerance

Gloss

Target gloss level, measuring angle and tolerance

Weathering

Required architectural coating specification and exposure performance

Salt / Corrosion Exposure

Test standard and environmental requirement for coastal or industrial projects

Chemical Resistance

Project-specific pollutants or cleaning agents where applicable

Solid Aluminum Cassette Panel Construction

A solid aluminum facade panel is commonly fabricated from a single aluminum sheet that is CNC cut and folded to form a cassette with perimeter returns.

Perimeter Edge Returns

Folded edges increase local panel stiffness and provide attachment zones for brackets, hooks or other fixing components. Return depth should follow the approved panel and installation drawings.

Corner Connections

Cassette corners can be mechanically connected or welded according to the panel geometry and approved fabrication procedure.

Stiffener Ribs

Large panels may require aluminum stiffeners or other engineered reinforcement on the rear side to control deflection, oil-canning and wind-pressure response.

Stiffener section, spacing and attachment method should be determined from structural calculations rather than using one universal spacing for all panels.

Custom CNC Fabrication

Flat Panels

Flat cassette panels can be manufactured according to facade setting-out drawings and panel schedules for conventional curtain-wall and rainscreen elevations.

Curved Panels

Curved aluminum panels can be fabricated for columns, entrance features, canopies and curved facade surfaces where forming radius, panel dimensions and surface appearance are confirmed in advance.

Perforated Panels

CNC punching or cutting can be used for project-specific perforation patterns. Hole dimensions, open area, edge distance and structural effect should be reviewed before production.

Special-Shaped Panels

Triangular, trapezoidal, folded, faceted and other architectural panels can be evaluated according to CAD or shop drawings and fabrication feasibility.

Curtain Wall and Ventilated Facade Applications

Solid aluminum panels can be used as the exterior rainscreen or decorative face of compatible curtain-wall and ventilated-facade systems.

The complete wall assembly may include aluminum panels, brackets, rails or keels, insulation, membranes, cavity barriers, sealants, fasteners and structural backing.

Thermal, acoustic, air-infiltration, water-penetration, fire and structural performance should therefore be evaluated at system level where the project requires those properties.

Wind Load and Panel Engineering

Exterior facade panels are subject to positive and negative wind pressures that vary with building height, location, facade zone and surrounding terrain.

Panel thickness should therefore not be selected solely from a generic rule such as “2.5mm for standard buildings” or “3mm for high-rise buildings.”

Engineering review should consider:

  • Design wind pressure and suction

  • Panel width and height

  • Aluminum alloy and temper

  • Panel thickness

  • Edge-return dimensions

  • Stiffener size and spacing

  • Bracket and fastener capacity

  • Subframe spacing

  • Allowable deflection

  • Facade corner and edge zones

Thermal Expansion and Joint Design

Aluminum expands and contracts with temperature changes. Large facade elevations and long panels require sufficient joint and fixing tolerance to accommodate thermal movement.

Panel joints, brackets and fixing slots should be detailed so that thermal movement does not create unacceptable panel distortion or stress.

Open-Joint Rainscreen

Open-joint systems use defined panel gaps together with an engineered cavity and weather-resistive backing system. Joint dimensions and cavity design should follow the facade system requirements.

Sealed-Joint System

Where panel joints are sealed, joint width, backing material, sealant type, adhesion and movement capability should be matched to the expected facade movement.

Installation Systems

Concealed Bracket System

Concealed cassette systems position the principal panel fixings behind the visible face, supporting a clean facade appearance with no exposed face screws where the approved system permits.

Open-Frame or Rail System

Panels can also be coordinated with aluminum or galvanized-steel rails, keels, brackets and other subframing according to the facade contractor's system design.

Subframe Adjustment

Adjustable brackets can help accommodate substrate tolerances and establish the required facade plane, cavity depth and panel alignment.

Installation Accessories

  • Aluminum or galvanized-steel subframe components

  • Adjustable brackets and connectors

  • Compatible stainless-steel fasteners

  • Panel hooks or fixing brackets

  • Isolation pads or separation materials where required

  • Backing rods and compatible sealants for sealed joints

  • Rubber or EPDM components where required by the system

  • Project installation drawings

Sealants, fasteners, membranes and fire-stopping materials should be selected according to the complete facade specification. A product should not be described as fireproof or waterproof solely because it is used with an aluminum panel.

Fire Performance

The principal substrate of a solid aluminum panel is a single metal sheet without a combustible polymer core.

However, the fire classification of the finished product or facade assembly can also depend on paint, sealants, insulation, membranes, cavity barriers, backing materials and the applicable national test method.

Where a project specifies Class A, A1, A2-s1,d0 or another classification, the exact standard and corresponding test report for the supplied construction should be confirmed before approval.

Solid Aluminum Panel vs Aluminum Composite Panel

Feature

Solid Aluminum Panel

Aluminum Composite Panel

Construction

Single solid aluminum alloy sheet

Aluminum skins bonded to a core

Core

No composite core

Core type varies by ACP product

Fabrication

Cutting, folding, welding, curving and stiffening possible

Routing and folding commonly used

Fire Performance

Metal substrate without polymer core; final classification requires applicable testing

Depends strongly on the composite core and complete tested product

Repair / Recoating

Single-metal panel can be refinished subject to project requirements

Depends on composite-panel construction and condition

ACP products are available with different core technologies and fire classifications, so they should not all be treated as having the same fire performance.

Flatness and Oil-Canning Control

Visual flatness depends on material thickness, alloy and temper, panel dimensions, fabrication stresses, edge returns, stiffener layout, coating temperature, support alignment and installation conditions.

The current product information lists a flatness reference of ≤0.5mm/m. Where this is an acceptance requirement, the panel size, measurement method and support condition should be agreed before manufacturing.

Large high-gloss or metallic panels can make small surface waviness more visually apparent, so panel mock-ups are recommended where facade appearance is critical.

Color, Metallic Finish and Batch Control

RAL references and custom colors can be supplied according to coating-system capability and project quantity.

For metallic, high-gloss and other direction-sensitive finishes, panels should be fabricated and installed with consistent coating orientation to reduce visible variation.

Large facade projects should use approved physical samples and coordinated production batches where practical. Color and gloss acceptance criteria can also be defined for project inspection.

Main Applications

  • Exterior curtain walls

  • Ventilated rainscreen facades

  • High-rise office-building cladding

  • Shopping-mall facades

  • Hotel exterior walls

  • Airport and railway-station facades

  • Exhibition halls

  • Hospitals and schools

  • Stadiums and public buildings

  • Museum facades

  • Building entrances and canopies

  • Column covers

  • Soffits and fascias

  • Interior feature walls

  • Building renovation projects

  • Curved and special-shaped architectural facades

Discuss Your Facade Project

Production Process

A typical production route can include 1050 aluminum-sheet inspection, cleaning and pretreatment, primer and PVDF finish application where pre-coated processing is used, curing, CNC cutting, punching, notching, folding, flanging, welding or riveting, stiffener assembly, protective-film application, final inspection and packaging.

Pretreatment chemistry and the sequence of coating and fabrication can vary according to the selected coating line and project specification. Where a specific chromium-free or other pretreatment is required, it should be identified before production.

Shop Drawings and Project Coordination

Custom facade panels should be produced from approved shop drawings or panel schedules rather than architectural elevation dimensions alone.

Typical drawings can identify:

  • Panel identification number

  • Finished panel width and height

  • Panel thickness

  • Perimeter return dimensions

  • Corner construction

  • Stiffener position and spacing

  • Bracket and hook locations

  • Joint dimensions

  • Hole and slot locations

  • Curvature or bend radius

  • Coating direction for metallic finishes

  • Installation position on the elevation

Mock-Up and Sample Approval

For large or visually critical facade projects, pre-production samples or full-size mock-ups can be used to review color, gloss, panel flatness, joints, corner details, coating orientation and installation appearance.

Where project performance testing is required, representative facade mock-ups can also be evaluated for structural, air or water performance according to the applicable system specification.

Quality Control

Inspection can include aluminum grade and thickness, panel dimensions, diagonals, edge returns, hole locations, flatness, stiffeners, surface appearance, coating thickness, color and gloss according to the approved drawings and inspection plan.

Where coating performance is contract-critical, adhesion, dry-film thickness, color difference and other specified tests can be included with the applicable method and acceptance criteria.

Fire, structural, air or water performance documentation should correspond to the actual material or facade system required by the project rather than being inferred from generic product descriptions.

Export Packaging

The coated face can be protected with removable PE film to reduce scratching during fabrication, transportation and installation.

Panels can be separated or wrapped with EPE foam or other protective material, with additional protection at corners and projecting fabricated edges.

Standard panels can be packed on reinforced pallets or in export crates, while curved, oversized or irregular panels can use project-specific supports to reduce deformation during transportation.

Each package can be labeled with panel number, dimensions, thickness, color, elevation or installation location and production batch according to the project packing schedule.

Information Required for a Quotation

To receive an accurate fabrication review and quotation, please provide as much of the following information as possible:

  • Architectural elevation or facade drawings

  • Panel schedule or CAD shop drawings, if available

  • Required aluminum alloy and temper

  • Panel thickness

  • Finished panel dimensions

  • Flat, curved, perforated or special-shaped construction

  • Panel edge-return depth

  • Required stiffener design or structural criteria

  • Design wind pressure or wind-load requirement

  • Subframe and fixing-system requirement

  • Joint width and open-joint or sealed-joint design

  • PVDF coating specification

  • Kynar 500 or other specified coating system

  • Required number of coating layers

  • Required dry-film thickness

  • AAMA 2605 or other coating-performance requirement, if applicable

  • RAL color or approved physical sample

  • Matte, gloss, metallic or other surface finish

  • Required fire classification and test standard

  • Air, water or structural test requirements, if applicable

  • Fasteners, brackets, rails or other accessories required

  • Protective-film requirements

  • Total panel quantity and facade area

  • Destination country and project location

  • Delivery port

  • Required material certificates, coating reports, inspection reports and packing labels

Send Your Facade Panel Drawings

FAQ

What is a solid aluminum cladding panel?

It is an architectural facade panel fabricated from a single solid aluminum alloy sheet rather than aluminum skins bonded to a composite core.

Is 1050 aluminum suitable for facade panels?

1050 aluminum provides good forming capability and corrosion resistance and can be fabricated into compatible cladding panels. Because its strength differs from commonly used 3003 or 5005 architectural alloys, panel thickness and reinforcement should be reviewed for the project loads.

How much aluminum does AA1050 contain?

AA1050 is a commercially pure aluminum grade containing a minimum of approximately 99.5% aluminum.

What panel thicknesses are available?

The current range includes 1.5mm, 2.0mm, 2.5mm, 3.0mm and 4.0mm solid aluminum panels.

Is 2.5mm the standard thickness for every curtain wall project?

No. 2.5mm is a commonly used thickness range for some facade panels, but final selection depends on panel dimensions, alloy, wind pressure, edge returns, stiffeners and fixing layout.

When should a 3mm panel be considered?

A 3mm panel can provide additional rigidity compared with thinner sheet, but suitability still requires review of the specific panel dimensions, structural loading and reinforcement design.

What is the maximum panel size?

The current published maximum is 1500mm wide by 6000mm long, subject to fabrication, flatness, structural, transportation and installation review.

Can curved and special-shaped panels be produced?

Yes. Flat, curved, perforated and other custom fabricated forms can be reviewed according to CAD or shop drawings and production feasibility.

What does 70% Kynar 500 mean?

For a licensed Kynar 500 coating formulation, the 70% reference relates to the minimum proportion of Kynar 500 PVDF resin in the total binder system. It does not mean that 70% of the complete dry paint film is fluoropolymer.

What PVDF coating thickness is available?

The current published coating thickness is 28μm to 40μm for the primer and topcoat system. Final construction should be confirmed with the project coating specification.

Does PVDF coating guarantee a 20–30 year service life?

No single service-life figure applies to every facade. Performance depends on coating formulation, pigment, pretreatment, film thickness, climate, UV exposure, coastal salt, pollution, panel detailing and maintenance.

Can an AAMA 2605 coating be supplied?

Where AAMA 2605 performance is required, it should be specified during quotation so the applicable coating system, formulator and supporting documentation can be confirmed.

Is solid aluminum panel fireproof?

The principal substrate is solid metal without a composite polymer core. However, any formal fire classification should correspond to the applicable test standard and the actual finished panel or facade assembly.

What is the difference between solid aluminum panel and ACP?

Solid aluminum panel uses a single aluminum sheet, while ACP uses aluminum skins bonded to a core. ACP products are available with different core types and fire classifications, so performance should be compared using the actual specified products.

Are stiffeners required on every panel?

Not necessarily. Stiffener requirements depend on panel dimensions, gauge, alloy, wind pressure, edge returns and allowable deflection. Large panels commonly require additional reinforcement.

Can you provide the subframe and installation accessories?

Aluminum or galvanized-steel subframe components, brackets, connectors, compatible fasteners and related accessories can be discussed according to the project installation system.

Can hidden fixing be used?

Yes. Concealed bracket, cassette, hook or rail arrangements can be reviewed according to the approved facade system and structural requirements.

Can custom RAL colors be supplied?

Yes. RAL references and project-specific colors can be discussed. Physical coated sample approval is recommended before bulk production.

How should metallic colors be installed?

Direction-sensitive metallic finishes should normally maintain a consistent coating orientation across adjacent facade panels to reduce visible color variation.

Can samples or facade mock-ups be provided?

Sample and mock-up requirements can be discussed according to panel size, coating, color, fabrication complexity and project approval procedures.

What drawings are required for custom panels?

CAD or shop drawings should identify panel dimensions, thickness, edge returns, bends, holes, stiffeners, brackets, joints, finish direction and installation position.

What information should I provide for a quotation?

Please provide panel drawings, thickness, dimensions, coating specification, RAL color, wind-load requirements, fixing system, stiffener requirements, fire or performance standards, quantity, project location and destination.

Contact Us for Facade Panel Pricing

Previous: 
Next: 

Product Category

Related Products

Consult Us To Get Your Customized Aluminum Solution

We help you specify and source the coated aluminum you need, on time and within budget.

Products

Application

Quick links

Follow Us

Contact Us

    joey@cnchangsong.com
    +86-18602595888
   Building 2, Zhixing Business Plaza, No.25 North Street, Zhonglou District, Changzhou City, Jiangsu Province, China
    Chaoyang road, Konggang economic development area, Lianshui, Huai'an city, Jiangsu,China
© COPYRIGHT 2026 CHANGZHOU DINGANG METAL MATERIAL CO., LTD. ALL RIGHTS RESERVED.