3000 series
Dingang
7606125900
| Availability: | |
|---|---|
| Quantity: | |
3000 series wood grain color coated aluminum coil is designed for architectural cladding, ceilings, soffits, decorative panels, roof-edge components and other formed building products requiring the appearance of natural wood with the lightweight and corrosion-resistant characteristics of aluminum.
The current product range uses AA3003, AA3004 and AA3105 aluminum substrates in O, H14, H16 and H18 tempers. Available thicknesses range from 0.12mm to 1.5mm, with widths from 1000mm to 1500mm for large-area architectural fabrication.
PE polyester and PVDF coating systems are available with customized wood grain patterns, matte or glossy appearance and project-specific color matching. Alloy, temper, coating and pattern should be selected according to the final panel profile, forming process, indoor or outdoor exposure and architectural performance requirements.
Request a Wood Grain Coil Quotation
Item | Published / Available Specification | Purchasing Consideration |
|---|---|---|
Alloy Grade | AA3003 / AA3004 / AA3105 | Select according to forming requirement, finished rigidity and panel design |
Temper | O / H14 / H16 / H18 | Softer tempers allow more forming; harder tempers provide greater rigidity |
Thickness Range | 0.12mm–1.5mm | Final thickness should reflect panel profile, backing, span between supports and fabrication method |
Width Range | 1000mm–1500mm | Suitable for large-area fabrication; width does not by itself determine structural span capacity |
Coating Type | PE polyester / PVDF | Select according to interior/exterior exposure, UV, weathering and forming requirements |
Surface Finish | Wood grain / Matte / Glossy | Physical wood-grain sample and finish approval recommended before bulk production |
Wood Grain Pattern | Custom patterns and colors available | Specify grain species reference, color tone, repeat and direction |
Standard Coil Weight | 500kg–3000kg per coil | Confirm coil ID, OD, maximum handling weight and production-line limits |
Current Published Tensile Reference | 110–180MPa | Final mechanical values should follow alloy, temper, thickness, standard and MTC |
Current Published Elongation Reference | ≥15% | Actual elongation varies by alloy, temper and gauge; confirm where forming is critical |
Published Fire Classification Reference | Class A1 reference currently published | Confirm applicable standard and test report for the exact coated product and finished construction |
Corrosion / Weather Exposure | Architectural exterior coating options available | Specify UV, coastal, industrial, humidity and chemical exposure conditions |
Processing | Cutting / Bending / Roll forming / Stamping where compatible | Coating flexibility should be verified for the actual forming geometry |
Mechanical properties and fire classification should be confirmed for the exact alloy, temper, thickness and coated construction where they are part of the project acceptance criteria.
Get Technical Specifications & Wood Grain Samples
3000-series aluminum alloys use manganese as a principal alloying element and are widely selected for sheet and coil applications requiring moderate strength, corrosion resistance and practical forming characteristics.
Compared with commercially pure 1xxx-series aluminum, 3xxx-series alloys can provide additional strength while retaining useful workability for compatible architectural forming operations.
AA3003 is a widely used aluminum-manganese alloy with moderate strength, good corrosion resistance and useful forming characteristics. It can be considered for decorative cladding, ceilings and formed architectural sheet products.
AA3004 contains manganese together with magnesium and can be selected where the finished component requires higher mechanical strength than a comparable 3003 construction, subject to forming requirements.
AA3105 is commonly used for painted building sheet products and can provide a practical balance of strength, forming capability and exterior architectural suitability.
Temper | General Characteristic | Selection Direction |
|---|---|---|
O | Annealed, highest forming allowance among the listed conditions | Consider for more severe forming where lower finished rigidity is acceptable |
H14 | Strain-hardened condition with moderate strength | Useful for general architectural forming and panel fabrication |
H16 | Higher strain-hardened strength than H14 | Consider where greater rigidity is required with controlled forming |
H18 | Full-hard strain-hardened condition | Higher rigidity with less forming allowance; profile validation recommended |
Alloy and temper should be selected together. A specification such as “3000 series” alone is not sufficient when bend radius, panel stiffness or mechanical performance is important.
Wood grain coated aluminum reproduces the visual direction, color variation and pattern characteristics of timber while using a factory-coated aluminum substrate.
Available designs can be developed around light oak, dark oak, walnut, teak, cedar and other architectural wood-tone references according to approved physical samples.
Grain direction should be identified on drawings and production orders. Adjacent facade or ceiling panels should normally maintain the specified orientation unless the architectural design intentionally varies the pattern.
For large continuous elevations, the wood-grain repeat can become visible. Buyers should review the pattern repeat, panel dimensions and installation layout before approving large-area production.
Large projects should use an approved master sample and coordinated production batches where practical. Color difference, gloss and pattern appearance can be included in the inspection requirements.
Matte finishes can create a lower-reflectivity timber appearance, while glossy finishes provide a more reflective decorative effect. Final selection should be made from physical samples under representative lighting.
Selection Factor | PE Polyester | PVDF |
|---|---|---|
Typical Application | Interior, sheltered and general architectural applications where the selected system meets exposure requirements | Exterior applications requiring higher UV and weathering performance |
Color / Pattern Retention | Depends on polyester formulation, pigment and exposure | Generally selected where stronger long-term exterior color retention is required |
Forming | Coating flexibility should be matched to bend severity | Coating construction should also be verified for post-forming applications |
Coastal / Industrial Exposure | Requires project-specific review | Can be considered where the complete coating and pretreatment system is qualified for the exposure |
PE and PVDF identify coating families rather than fixed service-life periods. Actual exterior durability depends on coating formulation, pretreatment, pigment selection, film construction, UV intensity, humidity, salt deposition, pollution, fabrication and maintenance.
Performance Item | What to Confirm |
|---|---|
Coating Construction | Primer, wood-grain color layers, protective clear coat where applicable and total dry-film requirement |
T-Bend / Flexibility | Required T-bend or representative panel-forming test |
Adhesion | Applicable cross-cut or tape test and required result |
Pencil Hardness | Required value and test method where specified |
Color Difference | Approved master sample and permitted color tolerance |
Gloss | Target gloss, measuring angle and tolerance |
Pattern Repeat | Repeat length and visual acceptance for large-area installation |
Weathering | Applicable outdoor or accelerated-weathering performance |
Corrosion Exposure | Salt-spray or cyclic-corrosion requirement where applicable |
Chemical Resistance | Cleaning products, industrial pollutants and project-specific exposure |
The 1000–1500mm coil width is suitable for fabricating relatively large architectural panels and profiles and can help reduce the number of intermediate joints compared with narrower material.
For stadiums, exhibition centers, airports, railway stations and other wide-span buildings, the aluminum coil is normally converted into a non-structural or system-supported architectural skin, ceiling, soffit, fascia or formed panel.
The aluminum coil itself should not be treated as a free-spanning load-bearing element. Structural capacity is determined by the finished profile, panel geometry, support rails, purlins, subframe, fixing system and engineering calculations.
Wider blanks can reduce the number of seams in large-area cladding or ceiling layouts where the finished panel dimensions and manufacturing equipment permit.
Large wood-grain panels can make surface waviness and misalignment more visible. Where flatness is critical, buyers should define measurement conditions for the coil, fabricated panel or installed assembly.
Large exterior aluminum panels expand and contract with temperature changes. Panel joints and fixing details should allow appropriate thermal movement without creating unacceptable buckling or distortion.
Wood grain color coated aluminum can be formed into decorative wall panels, facade cassettes, siding profiles, rainscreen components and column-cover skins according to project drawings.
The coil is the decorative raw material rather than the complete curtain-wall or rainscreen system. Wind load, brackets, rails, cavity, insulation, membranes, fire barriers and fasteners should be designed at system level.
Wood grain aluminum can provide a timber-inspired appearance for airport ceilings, station halls, shopping centers, stadium concourses, entrance canopies and exterior soffits.
The finished ceiling or soffit may use formed panels, strips, baffles or other profiles. Temper and thickness should therefore be matched to the specific forming method and suspension system.
Wood grain prepainted aluminum can be used for compatible roof-edge details, eaves, canopies and formed architectural roofing components where the coating and material specification meet exterior exposure requirements.
Where the material is formed into a roofing profile, structural span, wind uplift, water drainage, fasteners and roof-system performance should be evaluated separately from the decorative coil specification.
Airport terminals
Railway stations
Exhibition centers
Stadiums and sports facilities
Shopping malls
Hotels and resorts
Cultural and arts centers
Museums and public buildings
Commercial entrance canopies
Corridor ceilings and soffits
Decorative wall panels
Column covers and architectural trim
Wood grain aluminum can be used as decorative cladding, entrance panels, office-area facades, ceilings and other architectural components in factories, warehouses and logistics buildings.
Industrial environments should be reviewed for chemical fumes, dust, humidity and cleaning requirements before the coating system is selected.
For coastal or high-humidity architecture, selection should consider distance from the sea, salt deposition, rainfall, condensation, UV exposure and the condition of cut edges and fasteners.
PVDF can be considered where higher exterior weathering and color-retention performance is required, but coating chemistry alone does not guarantee performance in every coastal environment.
Where aluminum panels contact steel, copper or other metals in wet conditions, appropriate isolation, compatible fasteners and drainage details should be used to reduce galvanic-corrosion risk.
The aluminum substrate is metallic, but formal reaction-to-fire classification should be based on the exact finished coated product and the applicable test standard.
The current product information includes a Class A1 reference. Where A1 or another classification is required for bidding or building approval, buyers should request the corresponding valid test or classification report for the exact coating construction, thickness and intended use.
The classification of a color coated aluminum coil should also not be used automatically as the fire rating of a complete wall, roof or ceiling assembly containing insulation, membranes, adhesives, sealants or other components.
Minimum bend radius depends on alloy, temper, thickness and coating flexibility. Tight architectural folds should be validated using the specified wood-grain coating construction.
Long strips and architectural profiles can be roll formed where the selected temper and coating system are compatible with the forming sequence.
Punching or stamping can be evaluated for suitable applications. Tooling should be clean and appropriately designed to reduce damage to the visible decorative surface.
No universal crack-free statement should be assumed after forming. Where appearance at folded edges is important, buyers can specify a T-bend requirement or representative panel-forming trial before bulk production.
Large architectural projects should approve physical wood-grain samples rather than relying only on digital color references.
Recommended approval items include:
Wood species or visual reference
Base color and grain color
Pattern repeat
Grain direction
Matte or glossy finish
Target gloss
Permitted color difference
Panel orientation on elevation drawings
Approved production sample
Routine cleaning requirements depend on location, pollution level, coating system and panel orientation.
Where cleaning is required, the coating supplier's recommended procedures should be followed. Mild cleaning products and non-abrasive methods are generally preferable to aggressive solvents or abrasive tools.
Maintenance intervals and lifecycle costs should be assessed for the actual building rather than assigned as a fixed percentage relative to natural wood.
Discuss Your Architectural Wood Grain Project
Inspection Item | What to Confirm |
|---|---|
Alloy and Temper | 3003 / 3004 / 3105 and specified O / H14 / H16 / H18 condition |
Metal Thickness | Nominal gauge, tolerance and measurement method |
Width | Required width and tolerance |
Wood Grain Pattern | Approved master sample, repeat and grain orientation |
Color Difference | Approved sample and permitted tolerance |
Gloss | Target gloss and measuring method |
Coating Adhesion | Applicable test method and minimum result |
T-Bend / Formability | Specified test or representative finished profile |
Surface Appearance | Scratches, coating defects, contamination and pattern uniformity |
Coil Quality | Core, OD, coil weight, winding and edge condition |
Coils can be supplied according to the customer's slitting, leveling, roll-forming or panel-fabrication equipment.
Customers should specify core inner diameter, maximum outside diameter, preferred coil weight, winding direction and painted-side orientation where these parameters are important to production.
Export packing can include moisture-resistant wrapping, edge protection and suitable wooden pallets or supports according to coil width, weight and transportation conditions.
To receive an accurate wood grain aluminum coil quotation, please provide as much of the following information as possible:
Required alloy: 3003, 3004 or 3105
Required temper: O, H14, H16 or H18
Metal thickness and tolerance
Required width and tolerance
PE or PVDF coating
Wood species or visual pattern reference
Physical color sample, if available
Pattern repeat requirement
Grain direction
Matte or glossy finish
Target gloss and tolerance
Required coating construction or dry-film thickness, if specified
Facade, ceiling, soffit, roofing, trim or other application
Finished panel dimensions
Panel or profile drawing
Minimum bend radius or T-bend requirement
Coating-adhesion requirement
Interior, general exterior, coastal or industrial environment
Required weathering or corrosion test
Required fire-classification report, if applicable
Protective-film requirement, if applicable
Core inner diameter
Maximum coil outside diameter
Preferred or maximum coil weight
Winding direction
Required MTC and coating test reports
Order quantity
Destination country or delivery port
Special labeling and export-packing requirements
Send Your Wood Grain Coil Specifications
It is prepainted aluminum coil using 3003, 3004 or 3105 substrates with a decorative wood grain finish for architectural panels, ceilings, soffits, cladding and other formed building products.
3000-series alloys use manganese and can provide higher strength than commercially pure aluminum while maintaining useful corrosion resistance and formability. The correct choice still depends on the final profile and temper.
All three belong to the 3xxx-series family but have different compositions and mechanical-property ranges. Selection should be based on required strength, forming behavior, temper, thickness and project specification.
The current published thickness range is 0.12mm to 1.5mm.
The current published width range is 1000mm to 1500mm.
It is a useful wide format for many architectural panels, but ultra-wide coil specifications can extend beyond 1500mm. The required width should be selected from the finished panel layout and fabrication equipment.
No. Coil width is not the same as structural span capacity. The finished panel or profile requires appropriate supports, rails, purlins or subframing according to structural calculations.
Yes, it can be fabricated into suitable decorative cladding, ceiling, soffit and architectural components for large public buildings when the complete panel system meets project requirements.
PE can be considered for many interior, sheltered and general applications. PVDF is generally preferred where higher exterior UV and weathering performance is required.
No fixed service period or zero-fade guarantee applies to every project. Performance depends on coating formulation, pigments, pretreatment, film construction, climate, UV, salt exposure and maintenance.
Yes. Wood grain color, visual style, gloss and pattern can be developed according to physical samples and production feasibility.
Wood patterns have a visible direction. Adjacent panels installed in inconsistent directions can show obvious visual differences even when they come from the same production batch.
Pattern repeat is the distance before a wood-grain design begins repeating. It can be important on large walls or ceilings where repeated motifs may become visually noticeable.
No universal crack-free guarantee should be assumed. Alloy, temper, thickness, bend radius and coating flexibility all affect post-forming appearance.
Yes. Buyers can specify a T-bend requirement or request representative panel-forming trials for applications with visible folded edges.
The current product information contains a Class A1 reference. Where formal A1 classification is required, the applicable test standard and current report for the exact coated product should be verified before project approval.
Not automatically. Complete systems can also contain insulation, membranes, adhesives, sealants, subframes and other materials that affect system-level fire performance.
It can be considered for coastal projects when the coating, pretreatment, fasteners, cut edges and maintenance requirements are selected for the actual salt exposure and environment.
No exterior architectural material should be assumed to require zero maintenance. Cleaning frequency depends on coating type, pollution, salt exposure, panel orientation and building location.
Sample availability can be confirmed according to alloy, thickness, wood grain pattern, coating and finish. Physical sample approval is recommended before large architectural orders.
Please provide alloy, temper, thickness, width, PE or PVDF coating, wood grain reference, pattern direction, gloss, final architectural application, forming requirements, coil configuration, required reports, quantity and destination.