Aluminum Alloy 1xxx 3xxx
Dingang
| Aluminum Alloy: | |
|---|---|
| Aluminum Foil Thickness: | |
| Color Options::: | |
| Coating Material: | |
| Coating Thickness: | |
| Surface Finish Options: | |
| Color Standard: | |
| Availability: | |
| Quantity: | |
PVDF coated aluminum coil is a premium prepainted aluminum material developed for architectural facades, curtain-wall panels, exterior cladding, metal roofing, standing-seam panels, fascias, soffits and canopy systems requiring long-term exterior color and weathering performance.
The current architectural range includes 3003, 3105 and 5052 aluminum alloys, with additional 1050, 1060 and 1100 options available in the broader product range. Base aluminum thicknesses from 0.2mm to 3.0mm are currently listed, subject to alloy, temper and final fabrication requirements.
For demanding exterior applications, a 70% PVDF resin-based coating system can provide excellent resistance to ultraviolet exposure, chalking and color change when combined with suitable aluminum pretreatment, primer, pigments, topcoat, back coating and controlled coil-coating conditions.
Request a PVDF Aluminum Coil Quotation
Item | Published / Available Specification | Architectural Purchasing Consideration |
|---|---|---|
Product Type | PVDF coated aluminum coil | For architectural facade, cladding, roofing and formed exterior components |
Available Alloys | 1050 / 1060 / 1100 / 3003 / 3105 / 5052 | 3003, 3105 and 5052 are principal architectural options on this product page |
Base Aluminum Thickness | 0.2–3.0mm | Specify nominal metal thickness and tolerance before coating |
PVDF Resin System | 70% PVDF resin-based system where specified | Confirm coating manufacturer, formulation and project performance requirements |
Top Coat | 15–25μm current published range | Specify required dry-film thickness according to coating system |
Primer | 5μm current published reference | Primer chemistry and film build influence adhesion and corrosion resistance |
Back Coat | 5–10μm current published range | Select according to backside exposure, insulation bonding or panel fabrication |
T-Bend | ≤2T current published reference | Confirm alloy, temper, gauge, coating system and test method |
Color Standard | RAL / Pantone / Customer sample | Physical coated sample recommended for architectural approval |
Surface Finish | High gloss / Matte / Textured / Embossed | Finish availability depends on color, coating formulation and fabrication process |
Protective Film | PE protective film available | Specify tack, UV exposure, removal period and forming compatibility |
Width / Coil ID / Coil Weight | Confirm according to order | Match slitting, decoiling, roll-forming and transport equipment |
Where coating thickness, T-bend, weathering, salt-spray, color retention or adhesion are contract-critical, the applicable test method, specimen preparation and acceptance criteria should be agreed before production.
Request Technical Data & Color Samples
Architectural 70% PVDF coatings use a fluoropolymer resin system formulated for demanding exterior metal applications.
The term “70% PVDF” refers to the proportion of PVDF within the resin component of the coating formulation under the applicable coating-system specification. It should not be interpreted as meaning that 70% of the total cured coating film by weight is PVDF.
PVDF provides excellent resistance to ultraviolet radiation and contributes to long-term exterior durability, color retention and chalk resistance.
Architectural PVDF systems can include compatible resin modifiers that help balance coating hardness, adhesion and fabrication performance.
Pigment chemistry strongly influences color stability. Different architectural colors can therefore have different weathering behavior even when the same PVDF resin system is used.
Pretreatment prepares the aluminum surface for primer application and contributes to coating adhesion and corrosion resistance. The exact pretreatment should be compatible with the alloy and coating system.
Primer provides the bonding interface between the pretreated aluminum and PVDF topcoat. Primer quality is an important part of maintaining coating adhesion during forming and long-term weather exposure.
The topcoat provides the primary architectural color and contributes to UV, chalking, chemical and weathering resistance.
Back coating should be selected according to condensation exposure, adhesive bonding, foam lamination, panel fabrication and the final building-envelope construction.
Some metallic or special-effect architectural coating systems can use an additional clear layer to protect metallic pigments and achieve the required visual finish. The exact two-coat or three-coat system should be confirmed for each color.
PVDF resin-based architectural coatings are widely selected for exterior metal because they offer strong resistance to ultraviolet exposure and weathering.
Color retention depends on both resin and pigment selection. For large facade projects, color performance should therefore be reviewed using the exact approved formulation rather than the PVDF resin name alone.
Gloss can change gradually during exterior exposure. Where gloss retention is important, buyers should specify the initial gloss, measurement geometry and permitted change after the required weathering test.
Chalking is the formation of a powdery surface as an organic coating weathers. Architectural PVDF systems are selected in part for their resistance to this type of degradation.
A fixed exterior life should not be assumed from the term “70% PVDF” alone. Actual durability depends on coating formulation, pigment, pretreatment, film thickness, climate, orientation, pollution and maintenance, together with any project-specific coating warranty.
Architectural coating performance can be evaluated using both long-term natural exposure and accelerated laboratory weathering.
Natural exposure provides useful evidence of how an exact coating formulation and pigment system behave under real sunlight, humidity, rain and temperature cycling.
Accelerated laboratory testing can compare color change, gloss loss, chalking and coating degradation under controlled exposure conditions. The required test procedure and acceptance values should be agreed for contract-critical projects.
Accelerated weathering hours should not automatically be converted into a fixed number of exterior service years because real climates differ in UV intensity, humidity, pollutants, rainfall and temperature.
For European procurement, EN 1396 is a directly relevant specification for coil-coated aluminum sheet and strip for general applications.
Projects can use applicable requirements covering:
Aluminum dimensions and thickness tolerances
Mechanical properties
Coating thickness
Bend and flexibility testing
Coating adhesion
Color
Corrosion performance
UV and environmental exposure
Inspection and delivery requirements
Where detailed testing is required, coil-coated metal test methods should be selected according to the property being controlled.
Property | What to Define |
|---|---|
Dry-Film Thickness | Layer measured, instrument and acceptance tolerance |
Gloss | Measurement geometry and required range |
Color Difference | Color space, illuminant, observer and permitted ΔE |
T-Bend | Bend method, inspection criteria and permitted coating damage |
Adhesion | Test method before and, where required, after forming |
Hardness | Applicable test method and minimum grade where required |
Corrosion | Test duration, specimen preparation and acceptance criteria |
Weathering | Exposure method and permitted color, gloss or chalking change |
The current product information lists a T-bend reference of ≤2T. Actual forming performance depends on both the aluminum substrate and the complete coating construction.
A softer temper can generally accommodate tighter forming than a harder condition, but the final choice must also satisfy panel strength, flatness and structural requirements.
Thicker aluminum and tighter tooling radii can create greater forming strain. Bend performance should therefore be checked at the actual substrate thickness.
Primer, PVDF topcoat and any clear coat respond together during forming. A laboratory T-bend result should be linked to the exact coating build being supplied.
A coating that performs well in a standard bend test should not automatically be described as free from all micro-cracking under every stamping, folding or roll-forming geometry. Representative fabrication trials are recommended for tight architectural details.
AA3003 is commonly selected for architectural sheet and panel fabrication where useful formability and corrosion resistance are required. Final temper should match the forming operation.
AA3105 can be used for prepainted building products requiring a practical combination of strength, formability and coating compatibility.
AA5052 can be considered where greater substrate strength is required, subject to temper, bending radius and panel-forming requirements.
PVDF coated aluminum coil can be converted into solid aluminum panels and compatible facade components requiring durable architectural color and exterior weathering resistance.
Cutting, punching, routing, folding and roll forming should be planned around the alloy, temper, substrate gauge and minimum forming radius.
PVDF coated coil is a material input for facade panels. Structural wind resistance, anchors, support framing, water penetration, air infiltration, thermal movement and complete facade fire performance depend on the finished curtain-wall or cladding system.
For high-rise facade projects, specify panel dimensions, support system, design pressure, alloy, gauge, coating system and applicable facade testing separately.
PVDF systems can be formulated in solid, metallic, mica and other architectural finishes according to color and production requirements.
Metallic and mica finishes can appear different when panels are rotated because pigment orientation changes reflected light. Panel fabrication and installation should maintain the approved coil direction where appearance is critical.
Large facade elevations should preferably use controlled production batches or an agreed color-control plan to reduce visible variation between adjacent panels.
RAL or Pantone references are useful for communication, but final architectural approval should use an actual coated-metal sample where color and gloss are critical.
PVDF coated aluminum can be evaluated for coastal facade and roofing projects where the complete coating system, aluminum substrate and installation details are appropriate to salt and humidity exposure.
Salt can accumulate on sheltered facade zones that receive limited natural rain washing. Maintenance plans should consider periodic cleaning where deposits remain on coated surfaces.
Fastener and flashing selection should consider galvanic compatibility with aluminum, particularly where moisture and salt remain present.
Cut edges expose the aluminum substrate differently from the intact coated face. Edge condition, drainage and contact with other construction materials should be considered in severe environments.
Deep scratches or fabrication damage should be evaluated and repaired where required using procedures compatible with the specified coating system.
PVDF coated aluminum coil can be roll formed into compatible metal roofing and standing-seam profiles where the substrate and coating have sufficient forming capability.
Seam closing can place concentrated strain on the coating and substrate. Representative forming and seaming trials are recommended for tight single-lock and double-lock profiles.
PVDF coating does not determine wind-uplift capacity or structural roof strength. These depend on aluminum thickness, profile geometry, support spacing, clips or fasteners, seam design and the complete engineered roof system.
Water resistance depends on panel profile, seam geometry, slope, flashing, penetrations and installation. Coil coating alone does not establish complete roof-system watertightness.
PVDF coated aluminum can be fabricated into fascias, soffits, canopy panels, column covers and other architectural trim components requiring consistent exterior color.
For folded architectural details, the minimum bend radius and coating behavior should be reviewed using the actual alloy, temper and gauge.
PVDF coated aluminum can be used for compatible residential, commercial and institutional exterior panel systems where long-term color stability and weathering performance are priorities.
Project specifications should distinguish coating performance from structural panel performance and should identify the exact substrate, gauge, finish and fastening system required.
Temporary PE protective film can be applied to reduce scuffs, fingerprints and fabrication damage during slitting, panel forming, transportation and installation.
Protective-film adhesion should be strong enough to remain stable during fabrication while allowing clean removal without unacceptable residue or damage to the PVDF surface.
Where film remains on panels during outdoor storage or site installation, the permitted UV exposure period should be confirmed before use.
Temporary film should be removed according to the specified time and conditions. It is not part of the permanent architectural weathering system.
High-performance 70% PVDF coating formulations are commonly associated with demanding architectural coating specifications such as AAMA 2605.
If a project explicitly requires AAMA 2605 or another named architectural coating specification, buyers should request documentation from the coating formulator and applicator confirming that the exact coating system and application route satisfy the required specification.
The presence of PVDF resin or a statement of 70% PVDF alone should not be treated as automatic certification of every coated aluminum coil.
Inspection Item | What to Confirm |
|---|---|
Alloy and Temper | Specified aluminum alloy and temper against purchase requirements |
Base Metal Thickness | Nominal 0.2–3.0mm range as applicable, with required tolerance |
Width | Finished coil width and slitting tolerance |
Pretreatment | Specified pretreatment process and production control |
Primer Thickness | Current published reference 5μm or agreed project specification |
Top-Coat Thickness | Current published 15–25μm range or agreed coating-system requirement |
Back-Coat Thickness | Current published 5–10μm range or project requirement |
PVDF Resin System | Required 70% PVDF resin-based formulation and coating-supplier documentation where specified |
Color | Approved master sample and agreed color-difference criteria |
Gloss | Target gloss and measurement geometry |
T-Bend | ≤2T published reference or project-specific requirement, with defined inspection method |
Coating Adhesion | Required adhesion before and after forming where applicable |
Weathering | Required UV or outdoor exposure with color, gloss and chalking criteria |
Corrosion Resistance | Test method, duration, specimen condition and acceptance criteria |
Protective Film | Coverage, tack, UV exposure, peel behavior and residue |
Surface Appearance | Coating defects, scratches, color variation, contamination and gloss consistency |
Coil Quality | Winding, flatness, edge quality, telescoping, ID, OD and coil weight |
PVDF coated aluminum coils should be protected against moisture, edge damage, surface abrasion and coil deformation during storage and international transportation.
Export packaging can include moisture-resistant wrapping, robust pallet support, edge protection and secure banding according to coil size and shipment method.
Before fabrication, coils should be stored in a dry environment and protected from trapped condensation, aggressive chemicals and prolonged exposure of temporary protective film to sunlight.
For an accurate architectural PVDF coated aluminum coil quotation, please provide as much of the following information as possible:
Curtain wall, facade panel, roofing, soffit, fascia, canopy or other application
Project country and location
Coastal, urban, industrial or other exposure environment
Required aluminum alloy
Required temper
Base aluminum thickness and tolerance
Finished coil width and tolerance
Required 70% PVDF coating system
Named coating brand or resin system, if specified
Pretreatment requirement
Primer dry-film thickness
PVDF top-coat dry-film thickness
Back-coat type and thickness
Two-coat or three-coat construction
RAL, Pantone or physical color reference
Solid, metallic, mica or special-effect finish
Required gloss
Required color-difference tolerance
Required T-bend
Minimum forming radius
Coating-adhesion requirement
Weathering or UV test requirements
Color-retention requirement
Gloss-retention requirement
Chalking requirement
Corrosion or salt-spray requirement
AAMA, EN or other coating specification required by the project
Panel or profile drawing
Standing-seam, corrugation or panel-forming process
Protective-film requirement
Protective-film UV exposure and removal period
Coil inner diameter
Maximum coil outside diameter
Maximum coil weight
Required inspection reports or coating certificates
Order quantity
Destination country or delivery port
Send Your Architectural Coil Specifications
PVDF coated aluminum coil is factory prepainted aluminum finished with a fluoropolymer resin-based coating system for architectural and other demanding exterior metal applications.
70% PVDF resin-based formulations are widely used for high-performance exterior architectural coatings because they provide strong UV, chalking and color-retention performance when properly formulated and applied.
No. The percentage refers to PVDF within the applicable resin component of the coating formulation rather than 70% of the complete cured paint film.
The current product range lists 1050, 1060, 1100, 3003, 3105 and 5052, with 3003, 3105 and 5052 being important options for architectural facade and exterior applications.
The current product property range is 0.2mm to 3.0mm. Final thickness should match the panel design, forming process and structural requirements.
The current product information lists a top-coat range of 15–25μm, with a 5μm primer and 5–10μm back coat. Final film build should follow the specified coating system.
No. Exterior performance depends on the complete system including pretreatment, primer, PVDF formulation, pigment, film build, curing and substrate preparation.
The current product description references ≤2T. Actual performance should be verified against the specified alloy, temper, thickness and coating build.
No. Different panel folds, stamping operations and standing-seam geometries create different strain conditions. Representative forming trials are recommended for critical architectural details.
Yes, suitable PVDF coated coil can be fabricated into solid aluminum curtain-wall and facade panels. Complete curtain-wall structural, water, air and fire performance must be evaluated at system level.
Yes, appropriate coated aluminum can be used in high-rise facade products, but panel thickness, stiffeners, anchors, support framing and design wind pressure must be engineered separately.
No. Wind resistance depends on the aluminum substrate, finished panel geometry, support framing, anchors and complete facade or roofing system.
It can be evaluated for coastal projects. Salt exposure, drainage, fasteners, cut edges, cleaning, pretreatment and the complete coating system should all be considered.
No. PVDF coating provides environmental protection, but scratches, salt accumulation, aggressive chemicals and galvanic contact can still affect long-term corrosion behavior.
Yes. RAL, Pantone and customer-sample matching are available subject to coating formulation and production capability. Physical sample approval is recommended.
Metallic and special-effect finishes can be discussed. These colors may show directional appearance, so coil direction and panel installation orientation should be controlled.
Use approved physical samples, agreed color-difference criteria, controlled production batches and consistent panel orientation, especially for metallic finishes.
Yes, suitable alloy and coating combinations can be roll formed into standing-seam profiles. Forming and seam-closing trials are recommended for tight profiles.
No. Roof watertightness depends on panel geometry, seam design, slope, flashing, penetrations and installation quality.
Yes. It can be fabricated into compatible soffit, fascia, canopy and architectural trim components where the selected alloy and coating can accommodate the required forming.
No universal fixed-life claim should be made from resin type alone. Actual color retention depends on formulation, pigment, exposure environment and any coating-system warranty provided for the project.
EN 1396 is a specification for coil-coated aluminum and aluminum-alloy sheet and strip for general applications. It addresses relevant product properties, dimensions, coatings and testing.
No. Where AAMA 2605 is required, documentation for the exact coating formulation and applicable manufacturing or application system should be reviewed rather than assuming compliance from resin percentage alone.
Yes. Temporary PE protective film can be supplied for fabrication and installation protection. Tack, UV exposure and removal period should be confirmed before production.
Sample availability can be confirmed according to alloy, thickness, color, gloss and coating system. Physical sample and fabrication approval are recommended before large architectural orders.
Please provide application, project location, alloy, temper, base thickness, width, PVDF coating system, coating thickness, color, gloss, T-bend, weathering requirements, panel drawing, protective film, coil dimensions, quantity and destination.
Products
Application
Quick links