PVDF Coated Aluminum Coil for Premium Architectural Facades | High Weather Resistance
You are here: Home » Brushed Surface » Prepainted Aluminum Coil & Sheet » Color Coated Aluminum Coil » PVDF Coated Aluminum Coil for Premium Architectural Facades | High Weather Resistance

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

PVDF Coated Aluminum Coil for Premium Architectural Facades | High Weather Resistance

70% PVDF coated aluminum coil for architectural facades, curtain walls, roofing and exterior cladding, available in 3003/3105/5052 alloys with custom colors, matte, metallic and textured finishes.
  • Aluminum Alloy 1xxx 3xxx

  • Dingang

Aluminum Alloy:
Aluminum Foil Thickness:
Color Options:::
Coating Material:
Coating Thickness:
Surface Finish Options:
Color Standard:
Availability:
Quantity:

70% PVDF Coated Aluminum Coil for Architectural Facades

PVDF coated aluminum coil is a premium prepainted aluminum material developed for architectural facades, curtain-wall panels, exterior cladding, metal roofing, standing-seam panels, fascias, soffits and canopy systems requiring long-term exterior color and weathering performance.

The current architectural range includes 3003, 3105 and 5052 aluminum alloys, with additional 1050, 1060 and 1100 options available in the broader product range. Base aluminum thicknesses from 0.2mm to 3.0mm are currently listed, subject to alloy, temper and final fabrication requirements.

For demanding exterior applications, a 70% PVDF resin-based coating system can provide excellent resistance to ultraviolet exposure, chalking and color change when combined with suitable aluminum pretreatment, primer, pigments, topcoat, back coating and controlled coil-coating conditions.

Request a PVDF Aluminum Coil Quotation

Technical Specifications

Item

Published / Available Specification

Architectural Purchasing Consideration

Product Type

PVDF coated aluminum coil

For architectural facade, cladding, roofing and formed exterior components

Available Alloys

1050 / 1060 / 1100 / 3003 / 3105 / 5052

3003, 3105 and 5052 are principal architectural options on this product page

Base Aluminum Thickness

0.2–3.0mm

Specify nominal metal thickness and tolerance before coating

PVDF Resin System

70% PVDF resin-based system where specified

Confirm coating manufacturer, formulation and project performance requirements

Top Coat

15–25μm current published range

Specify required dry-film thickness according to coating system

Primer

5μm current published reference

Primer chemistry and film build influence adhesion and corrosion resistance

Back Coat

5–10μm current published range

Select according to backside exposure, insulation bonding or panel fabrication

T-Bend

≤2T current published reference

Confirm alloy, temper, gauge, coating system and test method

Color Standard

RAL / Pantone / Customer sample

Physical coated sample recommended for architectural approval

Surface Finish

High gloss / Matte / Textured / Embossed

Finish availability depends on color, coating formulation and fabrication process

Protective Film

PE protective film available

Specify tack, UV exposure, removal period and forming compatibility

Width / Coil ID / Coil Weight

Confirm according to order

Match slitting, decoiling, roll-forming and transport equipment

Where coating thickness, T-bend, weathering, salt-spray, color retention or adhesion are contract-critical, the applicable test method, specimen preparation and acceptance criteria should be agreed before production.

Request Technical Data & Color Samples

What 70% PVDF Means

Architectural 70% PVDF coatings use a fluoropolymer resin system formulated for demanding exterior metal applications.

The term “70% PVDF” refers to the proportion of PVDF within the resin component of the coating formulation under the applicable coating-system specification. It should not be interpreted as meaning that 70% of the total cured coating film by weight is PVDF.

PVDF Resin

PVDF provides excellent resistance to ultraviolet radiation and contributes to long-term exterior durability, color retention and chalk resistance.

Acrylic Modifier and Other Resin Components

Architectural PVDF systems can include compatible resin modifiers that help balance coating hardness, adhesion and fabrication performance.

Pigments

Pigment chemistry strongly influences color stability. Different architectural colors can therefore have different weathering behavior even when the same PVDF resin system is used.

Complete Architectural Coating System

Aluminum Pretreatment

Pretreatment prepares the aluminum surface for primer application and contributes to coating adhesion and corrosion resistance. The exact pretreatment should be compatible with the alloy and coating system.

Primer

Primer provides the bonding interface between the pretreated aluminum and PVDF topcoat. Primer quality is an important part of maintaining coating adhesion during forming and long-term weather exposure.

PVDF Topcoat

The topcoat provides the primary architectural color and contributes to UV, chalking, chemical and weathering resistance.

Back Coat

Back coating should be selected according to condensation exposure, adhesive bonding, foam lamination, panel fabrication and the final building-envelope construction.

Clear Coat for Selected Metallic Finishes

Some metallic or special-effect architectural coating systems can use an additional clear layer to protect metallic pigments and achieve the required visual finish. The exact two-coat or three-coat system should be confirmed for each color.

UV, Color and Chalking Resistance

PVDF resin-based architectural coatings are widely selected for exterior metal because they offer strong resistance to ultraviolet exposure and weathering.

Color Retention

Color retention depends on both resin and pigment selection. For large facade projects, color performance should therefore be reviewed using the exact approved formulation rather than the PVDF resin name alone.

Gloss Retention

Gloss can change gradually during exterior exposure. Where gloss retention is important, buyers should specify the initial gloss, measurement geometry and permitted change after the required weathering test.

Chalking

Chalking is the formation of a powdery surface as an organic coating weathers. Architectural PVDF systems are selected in part for their resistance to this type of degradation.

No Universal Service-Life Guarantee

A fixed exterior life should not be assumed from the term “70% PVDF” alone. Actual durability depends on coating formulation, pigment, pretreatment, film thickness, climate, orientation, pollution and maintenance, together with any project-specific coating warranty.

PVDF coated aluminum coil for architectural facade UV and color resistance
PVDF coated aluminum facade material for coastal corrosion protection
Formable PVDF coated aluminum coil for architectural fabrication

Natural and Accelerated Weathering

Architectural coating performance can be evaluated using both long-term natural exposure and accelerated laboratory weathering.

Natural Outdoor Exposure

Natural exposure provides useful evidence of how an exact coating formulation and pigment system behave under real sunlight, humidity, rain and temperature cycling.

Accelerated UV Testing

Accelerated laboratory testing can compare color change, gloss loss, chalking and coating degradation under controlled exposure conditions. The required test procedure and acceptance values should be agreed for contract-critical projects.

Accelerated Hours vs Real Service Years

Accelerated weathering hours should not automatically be converted into a fixed number of exterior service years because real climates differ in UV intensity, humidity, pollutants, rainfall and temperature.

EN 1396 and Coil-Coated Aluminum Quality

For European procurement, EN 1396 is a directly relevant specification for coil-coated aluminum sheet and strip for general applications.

Projects can use applicable requirements covering:

  • Aluminum dimensions and thickness tolerances

  • Mechanical properties

  • Coating thickness

  • Bend and flexibility testing

  • Coating adhesion

  • Color

  • Corrosion performance

  • UV and environmental exposure

  • Inspection and delivery requirements

Coil-Coating Test Methods

Where detailed testing is required, coil-coated metal test methods should be selected according to the property being controlled.

Property

What to Define

Dry-Film Thickness

Layer measured, instrument and acceptance tolerance

Gloss

Measurement geometry and required range

Color Difference

Color space, illuminant, observer and permitted ΔE

T-Bend

Bend method, inspection criteria and permitted coating damage

Adhesion

Test method before and, where required, after forming

Hardness

Applicable test method and minimum grade where required

Corrosion

Test duration, specimen preparation and acceptance criteria

Weathering

Exposure method and permitted color, gloss or chalking change

T-Bend and Architectural Formability

The current product information lists a T-bend reference of ≤2T. Actual forming performance depends on both the aluminum substrate and the complete coating construction.

Alloy and Temper

A softer temper can generally accommodate tighter forming than a harder condition, but the final choice must also satisfy panel strength, flatness and structural requirements.

Base Metal Thickness

Thicker aluminum and tighter tooling radii can create greater forming strain. Bend performance should therefore be checked at the actual substrate thickness.

Coating Build

Primer, PVDF topcoat and any clear coat respond together during forming. A laboratory T-bend result should be linked to the exact coating build being supplied.

No Universal Crack-Free Guarantee

A coating that performs well in a standard bend test should not automatically be described as free from all micro-cracking under every stamping, folding or roll-forming geometry. Representative fabrication trials are recommended for tight architectural details.

3003, 3105 and 5052 for Architectural Applications

AA3003

AA3003 is commonly selected for architectural sheet and panel fabrication where useful formability and corrosion resistance are required. Final temper should match the forming operation.

AA3105

AA3105 can be used for prepainted building products requiring a practical combination of strength, formability and coating compatibility.

AA5052

AA5052 can be considered where greater substrate strength is required, subject to temper, bending radius and panel-forming requirements.

Curtain Wall and Architectural Facade Panels

PVDF coated aluminum coil can be converted into solid aluminum panels and compatible facade components requiring durable architectural color and exterior weathering resistance.

Panel Fabrication

Cutting, punching, routing, folding and roll forming should be planned around the alloy, temper, substrate gauge and minimum forming radius.

Facade-System Boundary

PVDF coated coil is a material input for facade panels. Structural wind resistance, anchors, support framing, water penetration, air infiltration, thermal movement and complete facade fire performance depend on the finished curtain-wall or cladding system.

High-Rise Projects

For high-rise facade projects, specify panel dimensions, support system, design pressure, alloy, gauge, coating system and applicable facade testing separately.

Metallic, Mica and Special-Effect Colors

PVDF systems can be formulated in solid, metallic, mica and other architectural finishes according to color and production requirements.

Directional Appearance

Metallic and mica finishes can appear different when panels are rotated because pigment orientation changes reflected light. Panel fabrication and installation should maintain the approved coil direction where appearance is critical.

Batch Consistency

Large facade elevations should preferably use controlled production batches or an agreed color-control plan to reduce visible variation between adjacent panels.

Physical Sample Approval

RAL or Pantone references are useful for communication, but final architectural approval should use an actual coated-metal sample where color and gloss are critical.

Coastal and High-Humidity Facades

PVDF coated aluminum can be evaluated for coastal facade and roofing projects where the complete coating system, aluminum substrate and installation details are appropriate to salt and humidity exposure.

Salt Deposition

Salt can accumulate on sheltered facade zones that receive limited natural rain washing. Maintenance plans should consider periodic cleaning where deposits remain on coated surfaces.

Fasteners and Dissimilar Metals

Fastener and flashing selection should consider galvanic compatibility with aluminum, particularly where moisture and salt remain present.

Cut Edges

Cut edges expose the aluminum substrate differently from the intact coated face. Edge condition, drainage and contact with other construction materials should be considered in severe environments.

Coating Damage

Deep scratches or fabrication damage should be evaluated and repaired where required using procedures compatible with the specified coating system.

Metal Roofing and Standing-Seam Panels

PVDF coated aluminum coil can be roll formed into compatible metal roofing and standing-seam profiles where the substrate and coating have sufficient forming capability.

Standing-Seam Forming

Seam closing can place concentrated strain on the coating and substrate. Representative forming and seaming trials are recommended for tight single-lock and double-lock profiles.

Roof Structural Performance

PVDF coating does not determine wind-uplift capacity or structural roof strength. These depend on aluminum thickness, profile geometry, support spacing, clips or fasteners, seam design and the complete engineered roof system.

Waterproofing

Water resistance depends on panel profile, seam geometry, slope, flashing, penetrations and installation. Coil coating alone does not establish complete roof-system watertightness.

Fascias, Soffits and Canopy Coverings

PVDF coated aluminum can be fabricated into fascias, soffits, canopy panels, column covers and other architectural trim components requiring consistent exterior color.

For folded architectural details, the minimum bend radius and coating behavior should be reviewed using the actual alloy, temper and gauge.

Residential and Commercial Exterior Panels

PVDF coated aluminum can be used for compatible residential, commercial and institutional exterior panel systems where long-term color stability and weathering performance are priorities.

Project specifications should distinguish coating performance from structural panel performance and should identify the exact substrate, gauge, finish and fastening system required.

PVDF coated aluminum coil for curtain wall cladding and architectural facade systems

Protective Film

Temporary PE protective film can be applied to reduce scuffs, fingerprints and fabrication damage during slitting, panel forming, transportation and installation.

Film Tack

Protective-film adhesion should be strong enough to remain stable during fabrication while allowing clean removal without unacceptable residue or damage to the PVDF surface.

UV Exposure

Where film remains on panels during outdoor storage or site installation, the permitted UV exposure period should be confirmed before use.

Removal Period

Temporary film should be removed according to the specified time and conditions. It is not part of the permanent architectural weathering system.

AAMA 2605 and Architectural Coating Specifications

High-performance 70% PVDF coating formulations are commonly associated with demanding architectural coating specifications such as AAMA 2605.

If a project explicitly requires AAMA 2605 or another named architectural coating specification, buyers should request documentation from the coating formulator and applicator confirming that the exact coating system and application route satisfy the required specification.

The presence of PVDF resin or a statement of 70% PVDF alone should not be treated as automatic certification of every coated aluminum coil.

Quality Control

Inspection Item

What to Confirm

Alloy and Temper

Specified aluminum alloy and temper against purchase requirements

Base Metal Thickness

Nominal 0.2–3.0mm range as applicable, with required tolerance

Width

Finished coil width and slitting tolerance

Pretreatment

Specified pretreatment process and production control

Primer Thickness

Current published reference 5μm or agreed project specification

Top-Coat Thickness

Current published 15–25μm range or agreed coating-system requirement

Back-Coat Thickness

Current published 5–10μm range or project requirement

PVDF Resin System

Required 70% PVDF resin-based formulation and coating-supplier documentation where specified

Color

Approved master sample and agreed color-difference criteria

Gloss

Target gloss and measurement geometry

T-Bend

≤2T published reference or project-specific requirement, with defined inspection method

Coating Adhesion

Required adhesion before and after forming where applicable

Weathering

Required UV or outdoor exposure with color, gloss and chalking criteria

Corrosion Resistance

Test method, duration, specimen condition and acceptance criteria

Protective Film

Coverage, tack, UV exposure, peel behavior and residue

Surface Appearance

Coating defects, scratches, color variation, contamination and gloss consistency

Coil Quality

Winding, flatness, edge quality, telescoping, ID, OD and coil weight

Packaging and Storage

PVDF coated aluminum coils should be protected against moisture, edge damage, surface abrasion and coil deformation during storage and international transportation.

Export packaging can include moisture-resistant wrapping, robust pallet support, edge protection and secure banding according to coil size and shipment method.

Before fabrication, coils should be stored in a dry environment and protected from trapped condensation, aggressive chemicals and prolonged exposure of temporary protective film to sunlight.

Information Required for a Quotation

For an accurate architectural PVDF coated aluminum coil quotation, please provide as much of the following information as possible:

  • Curtain wall, facade panel, roofing, soffit, fascia, canopy or other application

  • Project country and location

  • Coastal, urban, industrial or other exposure environment

  • Required aluminum alloy

  • Required temper

  • Base aluminum thickness and tolerance

  • Finished coil width and tolerance

  • Required 70% PVDF coating system

  • Named coating brand or resin system, if specified

  • Pretreatment requirement

  • Primer dry-film thickness

  • PVDF top-coat dry-film thickness

  • Back-coat type and thickness

  • Two-coat or three-coat construction

  • RAL, Pantone or physical color reference

  • Solid, metallic, mica or special-effect finish

  • Required gloss

  • Required color-difference tolerance

  • Required T-bend

  • Minimum forming radius

  • Coating-adhesion requirement

  • Weathering or UV test requirements

  • Color-retention requirement

  • Gloss-retention requirement

  • Chalking requirement

  • Corrosion or salt-spray requirement

  • AAMA, EN or other coating specification required by the project

  • Panel or profile drawing

  • Standing-seam, corrugation or panel-forming process

  • Protective-film requirement

  • Protective-film UV exposure and removal period

  • Coil inner diameter

  • Maximum coil outside diameter

  • Maximum coil weight

  • Required inspection reports or coating certificates

  • Order quantity

  • Destination country or delivery port

Send Your Architectural Coil Specifications

FAQ

What is PVDF coated aluminum coil?

PVDF coated aluminum coil is factory prepainted aluminum finished with a fluoropolymer resin-based coating system for architectural and other demanding exterior metal applications.

Why is 70% PVDF commonly specified for architectural facades?

70% PVDF resin-based formulations are widely used for high-performance exterior architectural coatings because they provide strong UV, chalking and color-retention performance when properly formulated and applied.

Does 70% PVDF mean that 70% of the entire paint film is PVDF?

No. The percentage refers to PVDF within the applicable resin component of the coating formulation rather than 70% of the complete cured paint film.

What alloys are available?

The current product range lists 1050, 1060, 1100, 3003, 3105 and 5052, with 3003, 3105 and 5052 being important options for architectural facade and exterior applications.

What thickness is available?

The current product property range is 0.2mm to 3.0mm. Final thickness should match the panel design, forming process and structural requirements.

What PVDF top-coat thickness is available?

The current product information lists a top-coat range of 15–25μm, with a 5μm primer and 5–10μm back coat. Final film build should follow the specified coating system.

Is a thicker PVDF coating always better?

No. Exterior performance depends on the complete system including pretreatment, primer, PVDF formulation, pigment, film build, curing and substrate preparation.

What T-bend is currently published?

The current product description references ≤2T. Actual performance should be verified against the specified alloy, temper, thickness and coating build.

Does ≤2T guarantee that the coating will never crack?

No. Different panel folds, stamping operations and standing-seam geometries create different strain conditions. Representative forming trials are recommended for critical architectural details.

Can PVDF coated aluminum be used for curtain walls?

Yes, suitable PVDF coated coil can be fabricated into solid aluminum curtain-wall and facade panels. Complete curtain-wall structural, water, air and fire performance must be evaluated at system level.

Can the coil be used for high-rise buildings?

Yes, appropriate coated aluminum can be used in high-rise facade products, but panel thickness, stiffeners, anchors, support framing and design wind pressure must be engineered separately.

Does PVDF coating determine wind-load resistance?

No. Wind resistance depends on the aluminum substrate, finished panel geometry, support framing, anchors and complete facade or roofing system.

Can PVDF coated aluminum be used near the sea?

It can be evaluated for coastal projects. Salt exposure, drainage, fasteners, cut edges, cleaning, pretreatment and the complete coating system should all be considered.

Does PVDF make aluminum corrosion-proof?

No. PVDF coating provides environmental protection, but scratches, salt accumulation, aggressive chemicals and galvanic contact can still affect long-term corrosion behavior.

Can custom RAL colors be produced?

Yes. RAL, Pantone and customer-sample matching are available subject to coating formulation and production capability. Physical sample approval is recommended.

Can metallic and mica colors be supplied?

Metallic and special-effect finishes can be discussed. These colors may show directional appearance, so coil direction and panel installation orientation should be controlled.

How should color consistency be controlled on a large facade?

Use approved physical samples, agreed color-difference criteria, controlled production batches and consistent panel orientation, especially for metallic finishes.

Can PVDF coated aluminum be used for standing-seam roofs?

Yes, suitable alloy and coating combinations can be roll formed into standing-seam profiles. Forming and seam-closing trials are recommended for tight profiles.

Does the PVDF coating make a roof waterproof?

No. Roof watertightness depends on panel geometry, seam design, slope, flashing, penetrations and installation quality.

Can PVDF coated aluminum be used for soffits and fascias?

Yes. It can be fabricated into compatible soffit, fascia, canopy and architectural trim components where the selected alloy and coating can accommodate the required forming.

Does PVDF coating guarantee more than 20 years without fading?

No universal fixed-life claim should be made from resin type alone. Actual color retention depends on formulation, pigment, exposure environment and any coating-system warranty provided for the project.

What is EN 1396?

EN 1396 is a specification for coil-coated aluminum and aluminum-alloy sheet and strip for general applications. It addresses relevant product properties, dimensions, coatings and testing.

Does 70% PVDF automatically mean AAMA 2605 compliance?

No. Where AAMA 2605 is required, documentation for the exact coating formulation and applicable manufacturing or application system should be reviewed rather than assuming compliance from resin percentage alone.

Can protective film be supplied?

Yes. Temporary PE protective film can be supplied for fabrication and installation protection. Tack, UV exposure and removal period should be confirmed before production.

Can samples be supplied before a facade project is approved?

Sample availability can be confirmed according to alloy, thickness, color, gloss and coating system. Physical sample and fabrication approval are recommended before large architectural orders.

What information should I provide for a quotation?

Please provide application, project location, alloy, temper, base thickness, width, PVDF coating system, coating thickness, color, gloss, T-bend, weathering requirements, panel drawing, protective film, coil dimensions, quantity and destination.

PVDF coated aluminum coil for premium architectural facade and exterior cladding projects

Contact Us for PVDF Coil Samples & Pricing

Previous: 
Next: 

Product Category

Related Products

Consult Us To Get Your Customized Aluminum Solution

We help you specify and source the coated aluminum you need, on time and within budget.

Products

Application

Quick links

Follow Us

Contact Us

    joey@cnchangsong.com
    +86-18602595888
   Building 2, Zhixing Business Plaza, No.25 North Street, Zhonglou District, Changzhou City, Jiangsu Province, China
    Chaoyang road, Konggang economic development area, Lianshui, Huai'an city, Jiangsu,China
© COPYRIGHT 2026 CHANGZHOU DINGANG METAL MATERIAL CO., LTD. ALL RIGHTS RESERVED.