Architectural PVDF coated aluminum coil is a premium prepainted aluminum material developed for curtain-wall panels, solid aluminum facades, exterior cladding, cassette panels, roofing, louvers, sunshades, canopies and other high-exposure building-envelope applications.
The current range includes 1000-series, 3000-series and selected 5000-series aluminum substrates, with AA3003, AA3005, AA3105 and AA5052 available for demanding architectural fabrication depending on strength, formability and project requirements.
For premium exterior projects, a 70% PVDF resin-based fluoropolymer coating system can be specified together with controlled aluminum pretreatment, primer, color coat, back coat and application-specific film thickness. Where a project requires QUALICOAT, AAMA or another named architectural coating specification, the applicable coating-system and applicator documentation should be identified during technical approval.
Request an Architectural PVDF Coil Quotation
Item | Published / Available Specification | Architectural Project Consideration |
|---|---|---|
Product Type | Architectural PVDF coated aluminum coil | For facade panels, curtain walls, cassette panels, roofing and exterior cladding |
Available Alloys | 1050 / 1060 / 1100 / 3003 / 3005 / 3105 / 5052 | Select according to strength, formability, panel design and fabrication method |
Typical Architectural Alloys | AA3003 / AA3005 / AA3105 / AA5052 | Final alloy and temper should be specified separately |
Base Aluminum Thickness | 0.2–3.0mm | Specify actual base-metal gauge and dimensional tolerance before coating |
PVDF Resin System | 70% PVDF resin-based system available where specified | Confirm coating formulator, resin system and project documentation |
Top Coat | 15–25μm current published range | Specify dry-film thickness according to the actual two-coat or three-coat system |
Primer | 5μm current published reference | Primer chemistry and film build influence adhesion and corrosion performance |
Back Coat | 5–10μm current published range | Select according to backside environment, bonding and panel fabrication |
Color | RAL / Pantone / Customer sample | Physical coated-metal approval recommended for architectural projects |
Surface Finish | High gloss / Matte / Textured / Embossed / Special effect | Availability depends on coating formulation and fabrication requirements |
T-Bend | Project-specific / current architectural reference to be confirmed | Test actual alloy, temper, thickness and coating system |
Batch Color Control | Spectrophotometric control available | Specify master sample, ΔE method and allowable tolerance |
Protective Film | PE protective film available | Specify tack, UV exposure, removal period and residue requirements |
QUALICOAT Requirement | Project-specific documentation to be confirmed | Request applicable licence, approved coating system and pretreatment documentation where required |
EN 1396 Requirement | Can be specified according to project requirements | Define applicable dimensions, coating, bend, adhesion, color, UV and corrosion criteria |
Named architectural specifications, quality labels or coating brands should be supported by documentation applicable to the exact coating system and production route supplied for the project.
Request Coating Documentation & Samples
QUALICOAT is an architectural aluminum coating quality-label system based on defined requirements for coating plants, pretreatment, coating materials, production controls and finished coated products.
For procurement, a reference to QUALICOAT should identify the applicable licensed or approved entities rather than relying only on the name of the standard.
Where a project requires a QUALICOAT quality label, request the applicable coating-plant licence number, licence holder, validity period and production scope.
Where relevant to the project specification, the coating material approval should correspond to the exact organic coating system being applied.
Surface pretreatment is a critical part of architectural coating performance. The selected pretreatment should be compatible with the aluminum substrate, primer and intended exposure environment.
Facade consultants can request the coating system description, pretreatment information, production inspection records, color-control data and applicable third-party documentation during project approval.
A 70% PVDF architectural coating uses a fluoropolymer resin system developed for demanding exterior metal applications.
For a Kynar 500 resin-based coating, the 70% value refers to the proportion of Kynar 500 PVDF resin by weight within the total resin component of the coating formulation. It does not mean that 70% of the complete cured coating film is PVDF.
Where a branded Kynar 500 coating is required, the paint formulation should come from an appropriate licensed formulator and be applied according to the formulator's requirements.
Final coating behavior also depends on pigment chemistry, primer, pretreatment, additives, dry-film thickness, cure conditions and application quality.
The aluminum surface must be properly cleaned and prepared before conversion treatment and coating. Surface contamination can reduce primer adhesion and corrosion resistance.
Pretreatment provides the interface between the aluminum substrate and organic coating system. The selected process should be controlled for cleaning quality, conversion chemistry and coating compatibility.
Primer contributes to coating adhesion and corrosion resistance. The current product property information lists a primer reference of approximately 5μm.
The current product range lists a top-coat thickness of 15–25μm. The required dry-film build should be selected according to the complete coating system and project requirements.
The current back-coat range is 5–10μm. Back-coat chemistry should match panel bonding, insulation contact, condensation exposure and fabrication requirements.
Selected metallic, mica or special architectural finishes may require an additional barrier, effect or clear coat. The complete layer construction should be specified for these colors.
EN 1396 is a directly relevant specification for coil-coated aluminum and aluminum-alloy sheet and strip used in general applications.
For architectural procurement, applicable requirements can include:
Base aluminum dimensions and tolerances
Mechanical properties
Coating thickness
Coating adhesion
Bend performance
Color and gloss
Corrosion resistance
Environmental and UV exposure
Inspection and delivery requirements
70% PVDF architectural coatings are commonly associated with demanding exterior specifications such as AAMA 2605.
Where AAMA 2605 is specifically required, the buyer should request documentation supporting the exact coating formulation and applicable coating process rather than assuming compliance from the term “70% PVDF” alone.
PVDF resin-based coatings are widely selected for premium exterior aluminum because of their strong resistance to ultraviolet exposure, color change and chalking.
Color retention depends on the complete coating formulation and pigment package. Exact weathering data should therefore correspond to the approved project color.
Gloss retention should be evaluated against an initial gloss value and the required natural or accelerated exposure conditions.
Chalking is gradual formation of a powdery surface during organic coating weathering. Project specifications can define a maximum permitted chalk rating after the applicable exposure.
A fixed exterior service period should not be inferred solely from the words PVDF, Kynar 500 or QUALICOAT. Actual durability depends on coating formulation, pigment, pretreatment, environment, orientation, maintenance and any written project warranty.
Large architectural elevations require controlled color matching because panels fabricated from different coils can be installed immediately adjacent to one another.
For critical facade projects, use an approved physical coated-aluminum sample as the master standard rather than relying only on screen, printed RAL or Pantone references.
Production color can be monitored using spectrophotometric measurement against the approved master.
The current product information references tight batch color control. Where ΔE is contractual, the purchase specification should define the color-difference formula, illuminant, observer, instrument geometry and permitted value rather than relying on an unconditional universal limit.
Metallic and mica finishes can show directional visual variation that is not fully represented by a single numerical color reading. Coil direction, panel orientation and visual sample approval should therefore be controlled.
PVDF coated aluminum can be fabricated into architectural panels using cutting, punching, routing, bending and roll-forming processes when substrate and coating properties are correctly selected.
AA3003, AA3005, AA3105 and AA5052 can be specified in different temper conditions according to the required combination of strength and forming capability.
A T-bend result is useful for controlling coating flexibility, but it should be linked to the exact substrate gauge, temper, coating build and inspection method.
A laboratory bend result does not guarantee that every deep fold, cassette corner or roll-forming geometry will remain visually unchanged. Representative fabrication trials are recommended for demanding profiles.
PVDF coated aluminum coil or sheet can be converted into cassette-style facade panels using compatible cutting, punching, routing and folding processes.
Fold geometry should match the base-metal thickness, temper and minimum permitted bend radius. Very tight folds can increase strain on both aluminum and coating.
Large facade panels can visually reveal edge wave, oil canning or residual forming distortion. Where flatness is critical, the accepted panel or sheet-flatness criteria should be defined separately.
The coated sheet itself does not establish the structural capacity of a finished cassette. Panel dimensions, aluminum gauge, returns, stiffeners, anchors, support spacing and design pressure should be engineered as a complete system.
Architectural PVDF coated aluminum can provide the visible exterior skin for compatible curtain-wall and rainscreen cladding assemblies.
The coated aluminum is one material component. Wind resistance, anchorage, air infiltration, water penetration, drainage, thermal movement and complete facade fire performance are determined by the engineered facade assembly.
For high-rise projects, buyers should specify the panel construction, support system, design pressure, alloy, temper, gauge, coating specification and required system testing separately.
PVDF coated aluminum can be fabricated into exterior and interior architectural panels for airports, transit facilities, commercial hubs and other large public buildings.
Projects exposed to traffic emissions, frequent cleaning or abrasive dust should identify those conditions so the coating, color and maintenance requirements can be reviewed before approval.
Suitable PVDF coated aluminum coil can be roll formed into standing-seam roofing profiles where alloy, temper, gauge and coating flexibility are compatible with the forming and seaming process.
Single-lock and double-lock seams can create concentrated deformation. Representative roll-forming and seam-closing trials are recommended for critical projects.
PVDF coating does not determine wind-uplift, snow-load or watertightness performance. Those depend on the finished panel profile, clips, fasteners, seam geometry, support spacing, slope, flashing and complete roof design.
PVDF coated aluminum can be fabricated into exterior louvers, sunshades, canopy skins, column covers, fascia and entrance features requiring coordinated architectural colors.
Where multiple product types appear on one facade, use the same approved color standard and review differences caused by substrate geometry, gloss and coating application method.
Architectural PVDF coatings can be specified for demanding coastal and industrial projects, but no coating should be described as completely immune to salt, pollution or chemical exposure.
Coastal salt can accumulate on sheltered surfaces that receive limited rain washing. Project maintenance should address areas where contaminants can remain on coated aluminum.
Where a facade is exposed to chemical emissions, provide the expected pollutant type, concentration and cleaning conditions so the coating system can be reviewed for compatibility.
Fasteners, flashings and framing components should be selected with galvanic compatibility in mind, particularly in wet or salt-rich environments.
Cut edges and deep installation scratches expose the aluminum substrate differently from the intact coated surface and should be considered in severe environments.
Temporary PE protective film can be applied to protect the PVDF finish during sheet cutting, punching, routing, cassette forming, transportation and site installation.
Film adhesion should be sufficient for fabrication without causing unacceptable coating damage or adhesive residue during removal.
If panels remain outdoors with protective film attached, specify the permitted UV exposure and maximum removal period.
The removable film is fabrication protection only and is not part of the permanent PVDF weathering system.
Inspection Item | What to Confirm |
|---|---|
Alloy and Temper | Specified aluminum alloy and temper against purchase documentation |
Base Metal Thickness | Nominal gauge and dimensional tolerance before coating |
Pretreatment | Specified surface-preparation and conversion-treatment system |
Primer Thickness | Current 5μm reference or agreed project film build |
PVDF Top Coat | Current 15–25μm range or exact coating-system requirement |
Back Coat | Current 5–10μm range or project specification |
70% PVDF Resin System | Coating-formulator documentation where required |
Color | Approved master sample and agreed color-difference criteria |
Gloss | Target gloss and permitted variation |
T-Bend | Required bend performance for actual substrate and coating system |
Coating Adhesion | Adhesion before and after agreed deformation where applicable |
Weathering | Natural or accelerated exposure with color, gloss and chalking criteria |
Corrosion Resistance | Specified test method, duration, specimen preparation and acceptance criteria |
Flatness | Required coil, sheet or fabricated-panel flatness where applicable |
Protective Film | Tack, UV exposure, removal behavior and residue |
Coil Quality | Width, ID, OD, winding, edge condition, telescoping and coil weight |
Project Documentation | Applicable coating, pretreatment, quality-label or test documentation requested by the buyer |
Architectural PVDF coated coils should be protected against moisture, surface abrasion, edge impact and coil deformation during storage and transportation.
Export packing can include moisture-resistant wrapping, edge protection, secure banding and suitable wooden or engineered supports according to coil dimensions and shipment method.
Before fabrication, coils should be stored in a clean, dry area and protected from trapped condensation and contamination.
For an accurate architectural PVDF coated aluminum coil quotation, please provide as much of the following information as possible:
Curtain wall, cassette panel, roofing, louver, canopy or other application
Project country and location
Urban, coastal, industrial or other exposure environment
Required aluminum alloy
Required temper
Base aluminum thickness and tolerance
Coil width and tolerance
Required PVDF resin system
Kynar 500, Hylar or other named coating requirement, if specified
Required coating formulator
Pretreatment specification
Primer thickness
PVDF color-coat thickness
Back-coat type and thickness
Two-coat or three-coat system
RAL, Pantone or physical color reference
Solid, metallic, mica or special-effect color
Required gloss
Required ΔE method and tolerance
T-Bend requirement
Minimum fabrication radius
Coating adhesion requirement
Natural or accelerated weathering requirement
Color-retention requirement
Gloss-retention requirement
Chalking requirement
Corrosion test requirement
QUALICOAT requirement and requested licence documentation
EN 1396 requirement, if applicable
AAMA 2605 requirement, if applicable
Panel drawing and fabrication process
Cassette folding or standing-seam requirements
Protective-film specification
Coil inner diameter
Maximum coil outside diameter
Maximum coil weight
Required inspection reports or third-party documentation
Order quantity
Destination country or delivery port
Send Your Architectural Coating Specification
It is factory coil-coated aluminum using a high-performance fluoropolymer coating system for exterior facade, curtain-wall, roofing and other architectural applications.
QUALICOAT is an architectural aluminum coating quality-label system based on requirements for coating plants, coating materials, pretreatment systems, process control and finished-product quality.
No. Where a QUALICOAT label is required, buyers should verify the applicable licence or approval documentation for the coating plant, coating material and pretreatment system as required by the project.
Request the applicable licence number, licence holder, validity period, coating-system approval, pretreatment documentation and any project-specific test records required by the consultant.
For a Kynar 500 resin-based architectural coating, the 70% value refers to the PVDF proportion within the total resin component of the coating formulation rather than the percentage of the complete cured paint film.
No. Where AAMA 2605 is required, documentation supporting the exact coating formulation and applicable coating process should be reviewed.
The current range includes 1050, 1060, 1100, 3003, 3005, 3105 and 5052, subject to the required thickness, temper and fabrication process.
The current product range lists 0.2mm to 3.0mm base aluminum thickness, subject to alloy and production requirements.
The current product properties list a 15–25μm top coat, approximately 5μm primer and 5–10μm back coat. Final film build should follow the specified coating system.
Yes, both can be evaluated for compatible panel applications. The final alloy and temper should be selected according to panel size, gauge, bending requirements, stiffening and structural design.
No. Wind-load resistance depends on the complete facade panel and support system, including panel geometry, thickness, stiffeners, anchors and framing.
Cutting, punching, routing and folding can be performed with suitable material. True deep drawing should be evaluated separately because it imposes different strain on the aluminum and coating.
Yes, suitable coated aluminum can be fabricated into high-rise facade panels. Structural, air, water, thermal and fire performance must be established for the complete curtain-wall system.
Yes. RAL, Pantone and physical customer samples can be used as color references subject to formulation and production feasibility. Physical coated samples are recommended for final approval.
Tight color tolerances can be discussed, but the contractual value should define the color-difference formula, instrument geometry, illuminant, observer, master sample and whether the finish is solid, metallic or mica.
Metallic pigment orientation changes reflected light with viewing angle and panel direction. Visual approval and installation orientation should therefore be controlled in addition to instrumental color measurement.
Yes, suitable alloy, temper and coating combinations can be roll formed into standing-seam profiles. Representative forming and seam-closing trials are recommended for demanding profiles.
No. Watertightness depends on panel geometry, seam design, slope, flashings, penetrations and installation quality.
It can be evaluated for coastal applications. Pretreatment, coating system, salt deposition, fastener compatibility, cut edges and maintenance should all be considered.
No coating should be described as universally immune to every industrial contaminant. The expected pollutants and cleaning environment should be reviewed for the specific project.
No universal service-life guarantee should be inferred from the resin brand alone. Project durability depends on the exact coating formulation, pigment, application, environment and any written warranty provided for the specific order.
EN 1396 is a specification for coil-coated aluminum and aluminum-alloy sheet and strip for general applications, including relevant dimensional, mechanical, coating and performance requirements.
Yes. Temporary protective film can be supplied for fabrication and installation. Tack, UV exposure and removal time should be confirmed for the project.
Sample availability can be confirmed according to alloy, thickness, coating system, color and gloss. Physical color, coating and fabrication approval is recommended before large architectural orders.
Please provide application, project location, alloy, temper, base thickness, coil width, coating system, coating film build, color, gloss, ΔE requirement, bend requirement, weathering specification, required QUALICOAT or other documentation, coil dimensions, quantity and destination.