Qualicoat Standard PVDF Coated Aluminum Coil | Architectural Grade Exterior Cladding
You are here: Home » Brushed Surface » Prepainted Aluminum Coil & Sheet » Color Coated Aluminum Coil » Qualicoat Standard PVDF Coated Aluminum Coil | Architectural Grade Exterior Cladding

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Qualicoat Standard PVDF Coated Aluminum Coil | Architectural Grade Exterior Cladding

Architectural PVDF coated aluminum coil for facades, curtain walls and exterior cladding, using 70% PVDF resin-based coatings with custom alloys, colors, film builds and fabrication options.
  • Aluminum Alloy 1xxx 3xxx

  • Dingang

Aluminum Alloy:
Aluminum Foil Thickness:
Color Options:::
Coating Material:
Coating Thickness:
Surface Finish Options:
Color Standard:
Availability:
Quantity:

Architectural PVDF Coated Aluminum Coil for Exterior Cladding

Architectural PVDF coated aluminum coil is a premium prepainted aluminum material developed for curtain-wall panels, solid aluminum facades, exterior cladding, cassette panels, roofing, louvers, sunshades, canopies and other high-exposure building-envelope applications.

The current range includes 1000-series, 3000-series and selected 5000-series aluminum substrates, with AA3003, AA3005, AA3105 and AA5052 available for demanding architectural fabrication depending on strength, formability and project requirements.

For premium exterior projects, a 70% PVDF resin-based fluoropolymer coating system can be specified together with controlled aluminum pretreatment, primer, color coat, back coat and application-specific film thickness. Where a project requires QUALICOAT, AAMA or another named architectural coating specification, the applicable coating-system and applicator documentation should be identified during technical approval.

Request an Architectural PVDF Coil Quotation

Technical Specifications

Item

Published / Available Specification

Architectural Project Consideration

Product Type

Architectural PVDF coated aluminum coil

For facade panels, curtain walls, cassette panels, roofing and exterior cladding

Available Alloys

1050 / 1060 / 1100 / 3003 / 3005 / 3105 / 5052

Select according to strength, formability, panel design and fabrication method

Typical Architectural Alloys

AA3003 / AA3005 / AA3105 / AA5052

Final alloy and temper should be specified separately

Base Aluminum Thickness

0.2–3.0mm

Specify actual base-metal gauge and dimensional tolerance before coating

PVDF Resin System

70% PVDF resin-based system available where specified

Confirm coating formulator, resin system and project documentation

Top Coat

15–25μm current published range

Specify dry-film thickness according to the actual two-coat or three-coat system

Primer

5μm current published reference

Primer chemistry and film build influence adhesion and corrosion performance

Back Coat

5–10μm current published range

Select according to backside environment, bonding and panel fabrication

Color

RAL / Pantone / Customer sample

Physical coated-metal approval recommended for architectural projects

Surface Finish

High gloss / Matte / Textured / Embossed / Special effect

Availability depends on coating formulation and fabrication requirements

T-Bend

Project-specific / current architectural reference to be confirmed

Test actual alloy, temper, thickness and coating system

Batch Color Control

Spectrophotometric control available

Specify master sample, ΔE method and allowable tolerance

Protective Film

PE protective film available

Specify tack, UV exposure, removal period and residue requirements

QUALICOAT Requirement

Project-specific documentation to be confirmed

Request applicable licence, approved coating system and pretreatment documentation where required

EN 1396 Requirement

Can be specified according to project requirements

Define applicable dimensions, coating, bend, adhesion, color, UV and corrosion criteria

Named architectural specifications, quality labels or coating brands should be supported by documentation applicable to the exact coating system and production route supplied for the project.

Request Coating Documentation & Samples

QUALICOAT Requirements for Architectural Projects

QUALICOAT is an architectural aluminum coating quality-label system based on defined requirements for coating plants, pretreatment, coating materials, production controls and finished coated products.

For procurement, a reference to QUALICOAT should identify the applicable licensed or approved entities rather than relying only on the name of the standard.

Licensed Coating Plant

Where a project requires a QUALICOAT quality label, request the applicable coating-plant licence number, licence holder, validity period and production scope.

Approved Coating System

Where relevant to the project specification, the coating material approval should correspond to the exact organic coating system being applied.

Pretreatment System

Surface pretreatment is a critical part of architectural coating performance. The selected pretreatment should be compatible with the aluminum substrate, primer and intended exposure environment.

Project Documentation

Facade consultants can request the coating system description, pretreatment information, production inspection records, color-control data and applicable third-party documentation during project approval.

What 70% Kynar 500 or Equivalent PVDF Means

A 70% PVDF architectural coating uses a fluoropolymer resin system developed for demanding exterior metal applications.

For a Kynar 500 resin-based coating, the 70% value refers to the proportion of Kynar 500 PVDF resin by weight within the total resin component of the coating formulation. It does not mean that 70% of the complete cured coating film is PVDF.

Coating Formulator

Where a branded Kynar 500 coating is required, the paint formulation should come from an appropriate licensed formulator and be applied according to the formulator's requirements.

PVDF Resin Alone Does Not Define Final Performance

Final coating behavior also depends on pigment chemistry, primer, pretreatment, additives, dry-film thickness, cure conditions and application quality.

Architectural PVDF coated aluminum for controlled coating and pretreatment requirements
70 percent PVDF coated aluminum coil for exterior architectural cladding
Formable PVDF coated aluminum coil for architectural cassette panels
PVDF coated aluminum for demanding exterior facade environments

Complete Architectural PVDF Coating System

Aluminum Surface Preparation

The aluminum surface must be properly cleaned and prepared before conversion treatment and coating. Surface contamination can reduce primer adhesion and corrosion resistance.

Chemical Pretreatment

Pretreatment provides the interface between the aluminum substrate and organic coating system. The selected process should be controlled for cleaning quality, conversion chemistry and coating compatibility.

Primer

Primer contributes to coating adhesion and corrosion resistance. The current product property information lists a primer reference of approximately 5μm.

PVDF Color Coat

The current product range lists a top-coat thickness of 15–25μm. The required dry-film build should be selected according to the complete coating system and project requirements.

Back Coat

The current back-coat range is 5–10μm. Back-coat chemistry should match panel bonding, insulation contact, condensation exposure and fabrication requirements.

Three-Coat and Special-Effect Systems

Selected metallic, mica or special architectural finishes may require an additional barrier, effect or clear coat. The complete layer construction should be specified for these colors.

EN 1396 for Coil-Coated Aluminum

EN 1396 is a directly relevant specification for coil-coated aluminum and aluminum-alloy sheet and strip used in general applications.

For architectural procurement, applicable requirements can include:

  • Base aluminum dimensions and tolerances

  • Mechanical properties

  • Coating thickness

  • Coating adhesion

  • Bend performance

  • Color and gloss

  • Corrosion resistance

  • Environmental and UV exposure

  • Inspection and delivery requirements

AAMA 2605 Requirements

70% PVDF architectural coatings are commonly associated with demanding exterior specifications such as AAMA 2605.

Where AAMA 2605 is specifically required, the buyer should request documentation supporting the exact coating formulation and applicable coating process rather than assuming compliance from the term “70% PVDF” alone.

UV, Fade and Chalking Performance

PVDF resin-based coatings are widely selected for premium exterior aluminum because of their strong resistance to ultraviolet exposure, color change and chalking.

Color Retention

Color retention depends on the complete coating formulation and pigment package. Exact weathering data should therefore correspond to the approved project color.

Gloss Retention

Gloss retention should be evaluated against an initial gloss value and the required natural or accelerated exposure conditions.

Chalking

Chalking is gradual formation of a powdery surface during organic coating weathering. Project specifications can define a maximum permitted chalk rating after the applicable exposure.

Exterior Service Life

A fixed exterior service period should not be inferred solely from the words PVDF, Kynar 500 or QUALICOAT. Actual durability depends on coating formulation, pigment, pretreatment, environment, orientation, maintenance and any written project warranty.

Color Control and ΔE

Large architectural elevations require controlled color matching because panels fabricated from different coils can be installed immediately adjacent to one another.

Master Color Sample

For critical facade projects, use an approved physical coated-aluminum sample as the master standard rather than relying only on screen, printed RAL or Pantone references.

Spectrophotometer Control

Production color can be monitored using spectrophotometric measurement against the approved master.

ΔE Acceptance

The current product information references tight batch color control. Where ΔE is contractual, the purchase specification should define the color-difference formula, illuminant, observer, instrument geometry and permitted value rather than relying on an unconditional universal limit.

Metallic and Mica Colors

Metallic and mica finishes can show directional visual variation that is not fully represented by a single numerical color reading. Coil direction, panel orientation and visual sample approval should therefore be controlled.

Architectural Formability

PVDF coated aluminum can be fabricated into architectural panels using cutting, punching, routing, bending and roll-forming processes when substrate and coating properties are correctly selected.

Alloy and Temper

AA3003, AA3005, AA3105 and AA5052 can be specified in different temper conditions according to the required combination of strength and forming capability.

T-Bend

A T-bend result is useful for controlling coating flexibility, but it should be linked to the exact substrate gauge, temper, coating build and inspection method.

No Universal Crack-Free Claim

A laboratory bend result does not guarantee that every deep fold, cassette corner or roll-forming geometry will remain visually unchanged. Representative fabrication trials are recommended for demanding profiles.

Solid Aluminum Cassette Panels

PVDF coated aluminum coil or sheet can be converted into cassette-style facade panels using compatible cutting, punching, routing and folding processes.

Cassette Folding

Fold geometry should match the base-metal thickness, temper and minimum permitted bend radius. Very tight folds can increase strain on both aluminum and coating.

Panel Flatness

Large facade panels can visually reveal edge wave, oil canning or residual forming distortion. Where flatness is critical, the accepted panel or sheet-flatness criteria should be defined separately.

Structural Design

The coated sheet itself does not establish the structural capacity of a finished cassette. Panel dimensions, aluminum gauge, returns, stiffeners, anchors, support spacing and design pressure should be engineered as a complete system.

Curtain Wall and Exterior Facade Systems

Architectural PVDF coated aluminum can provide the visible exterior skin for compatible curtain-wall and rainscreen cladding assemblies.

Material vs Complete Facade System

The coated aluminum is one material component. Wind resistance, anchorage, air infiltration, water penetration, drainage, thermal movement and complete facade fire performance are determined by the engineered facade assembly.

High-Rise Facades

For high-rise projects, buyers should specify the panel construction, support system, design pressure, alloy, temper, gauge, coating specification and required system testing separately.

PVDF coated aluminum coil for premium curtain wall and exterior architectural facade panels

Airport, Transit and Public Infrastructure Cladding

PVDF coated aluminum can be fabricated into exterior and interior architectural panels for airports, transit facilities, commercial hubs and other large public buildings.

Projects exposed to traffic emissions, frequent cleaning or abrasive dust should identify those conditions so the coating, color and maintenance requirements can be reviewed before approval.

Standing-Seam Roofs

Suitable PVDF coated aluminum coil can be roll formed into standing-seam roofing profiles where alloy, temper, gauge and coating flexibility are compatible with the forming and seaming process.

Seam Forming

Single-lock and double-lock seams can create concentrated deformation. Representative roll-forming and seam-closing trials are recommended for critical projects.

Roof-System Boundary

PVDF coating does not determine wind-uplift, snow-load or watertightness performance. Those depend on the finished panel profile, clips, fasteners, seam geometry, support spacing, slope, flashing and complete roof design.

Louvers, Sunshades and Canopies

PVDF coated aluminum can be fabricated into exterior louvers, sunshades, canopy skins, column covers, fascia and entrance features requiring coordinated architectural colors.

Where multiple product types appear on one facade, use the same approved color standard and review differences caused by substrate geometry, gloss and coating application method.

Coastal and Industrial Environments

Architectural PVDF coatings can be specified for demanding coastal and industrial projects, but no coating should be described as completely immune to salt, pollution or chemical exposure.

Salt Deposition

Coastal salt can accumulate on sheltered surfaces that receive limited rain washing. Project maintenance should address areas where contaminants can remain on coated aluminum.

Industrial Pollutants

Where a facade is exposed to chemical emissions, provide the expected pollutant type, concentration and cleaning conditions so the coating system can be reviewed for compatibility.

Dissimilar Metals

Fasteners, flashings and framing components should be selected with galvanic compatibility in mind, particularly in wet or salt-rich environments.

Cut Edges and Scratches

Cut edges and deep installation scratches expose the aluminum substrate differently from the intact coated surface and should be considered in severe environments.

Protective Film

Temporary PE protective film can be applied to protect the PVDF finish during sheet cutting, punching, routing, cassette forming, transportation and site installation.

Film Tack

Film adhesion should be sufficient for fabrication without causing unacceptable coating damage or adhesive residue during removal.

UV Exposure

If panels remain outdoors with protective film attached, specify the permitted UV exposure and maximum removal period.

Protective Film Is Temporary

The removable film is fabrication protection only and is not part of the permanent PVDF weathering system.

Quality Control

Inspection Item

What to Confirm

Alloy and Temper

Specified aluminum alloy and temper against purchase documentation

Base Metal Thickness

Nominal gauge and dimensional tolerance before coating

Pretreatment

Specified surface-preparation and conversion-treatment system

Primer Thickness

Current 5μm reference or agreed project film build

PVDF Top Coat

Current 15–25μm range or exact coating-system requirement

Back Coat

Current 5–10μm range or project specification

70% PVDF Resin System

Coating-formulator documentation where required

Color

Approved master sample and agreed color-difference criteria

Gloss

Target gloss and permitted variation

T-Bend

Required bend performance for actual substrate and coating system

Coating Adhesion

Adhesion before and after agreed deformation where applicable

Weathering

Natural or accelerated exposure with color, gloss and chalking criteria

Corrosion Resistance

Specified test method, duration, specimen preparation and acceptance criteria

Flatness

Required coil, sheet or fabricated-panel flatness where applicable

Protective Film

Tack, UV exposure, removal behavior and residue

Coil Quality

Width, ID, OD, winding, edge condition, telescoping and coil weight

Project Documentation

Applicable coating, pretreatment, quality-label or test documentation requested by the buyer

Packaging and Storage

Architectural PVDF coated coils should be protected against moisture, surface abrasion, edge impact and coil deformation during storage and transportation.

Export packing can include moisture-resistant wrapping, edge protection, secure banding and suitable wooden or engineered supports according to coil dimensions and shipment method.

Before fabrication, coils should be stored in a clean, dry area and protected from trapped condensation and contamination.

Information Required for a Quotation

For an accurate architectural PVDF coated aluminum coil quotation, please provide as much of the following information as possible:

  • Curtain wall, cassette panel, roofing, louver, canopy or other application

  • Project country and location

  • Urban, coastal, industrial or other exposure environment

  • Required aluminum alloy

  • Required temper

  • Base aluminum thickness and tolerance

  • Coil width and tolerance

  • Required PVDF resin system

  • Kynar 500, Hylar or other named coating requirement, if specified

  • Required coating formulator

  • Pretreatment specification

  • Primer thickness

  • PVDF color-coat thickness

  • Back-coat type and thickness

  • Two-coat or three-coat system

  • RAL, Pantone or physical color reference

  • Solid, metallic, mica or special-effect color

  • Required gloss

  • Required ΔE method and tolerance

  • T-Bend requirement

  • Minimum fabrication radius

  • Coating adhesion requirement

  • Natural or accelerated weathering requirement

  • Color-retention requirement

  • Gloss-retention requirement

  • Chalking requirement

  • Corrosion test requirement

  • QUALICOAT requirement and requested licence documentation

  • EN 1396 requirement, if applicable

  • AAMA 2605 requirement, if applicable

  • Panel drawing and fabrication process

  • Cassette folding or standing-seam requirements

  • Protective-film specification

  • Coil inner diameter

  • Maximum coil outside diameter

  • Maximum coil weight

  • Required inspection reports or third-party documentation

  • Order quantity

  • Destination country or delivery port

Send Your Architectural Coating Specification

FAQ

What is architectural PVDF coated aluminum coil?

It is factory coil-coated aluminum using a high-performance fluoropolymer coating system for exterior facade, curtain-wall, roofing and other architectural applications.

What does QUALICOAT mean for an architectural aluminum project?

QUALICOAT is an architectural aluminum coating quality-label system based on requirements for coating plants, coating materials, pretreatment systems, process control and finished-product quality.

Does using PVDF automatically make a product QUALICOAT certified?

No. Where a QUALICOAT label is required, buyers should verify the applicable licence or approval documentation for the coating plant, coating material and pretreatment system as required by the project.

What documentation should I request for a QUALICOAT-specified project?

Request the applicable licence number, licence holder, validity period, coating-system approval, pretreatment documentation and any project-specific test records required by the consultant.

What does 70% Kynar 500 PVDF mean?

For a Kynar 500 resin-based architectural coating, the 70% value refers to the PVDF proportion within the total resin component of the coating formulation rather than the percentage of the complete cured paint film.

Does 70% PVDF automatically mean AAMA 2605 compliance?

No. Where AAMA 2605 is required, documentation supporting the exact coating formulation and applicable coating process should be reviewed.

Which aluminum alloys are available?

The current range includes 1050, 1060, 1100, 3003, 3005, 3105 and 5052, subject to the required thickness, temper and fabrication process.

What base aluminum thickness is available?

The current product range lists 0.2mm to 3.0mm base aluminum thickness, subject to alloy and production requirements.

What coating thickness is currently available?

The current product properties list a 15–25μm top coat, approximately 5μm primer and 5–10μm back coat. Final film build should follow the specified coating system.

Can AA3003 and AA5052 be used for cassette facade panels?

Yes, both can be evaluated for compatible panel applications. The final alloy and temper should be selected according to panel size, gauge, bending requirements, stiffening and structural design.

Does AA5052 automatically provide sufficient wind-load strength?

No. Wind-load resistance depends on the complete facade panel and support system, including panel geometry, thickness, stiffeners, anchors and framing.

Can the material be deeply formed into cassette panels?

Cutting, punching, routing and folding can be performed with suitable material. True deep drawing should be evaluated separately because it imposes different strain on the aluminum and coating.

Can PVDF coated aluminum be used for high-rise curtain walls?

Yes, suitable coated aluminum can be fabricated into high-rise facade panels. Structural, air, water, thermal and fire performance must be established for the complete curtain-wall system.

Can custom RAL and Pantone colors be supplied?

Yes. RAL, Pantone and physical customer samples can be used as color references subject to formulation and production feasibility. Physical coated samples are recommended for final approval.

Can batch color difference be controlled to ΔE ≤0.8?

Tight color tolerances can be discussed, but the contractual value should define the color-difference formula, instrument geometry, illuminant, observer, master sample and whether the finish is solid, metallic or mica.

Why are metallic colors more difficult to match?

Metallic pigment orientation changes reflected light with viewing angle and panel direction. Visual approval and installation orientation should therefore be controlled in addition to instrumental color measurement.

Can the coil be used for standing-seam roofing?

Yes, suitable alloy, temper and coating combinations can be roll formed into standing-seam profiles. Representative forming and seam-closing trials are recommended for demanding profiles.

Does PVDF coating make the roof waterproof?

No. Watertightness depends on panel geometry, seam design, slope, flashings, penetrations and installation quality.

Can PVDF coated aluminum be used near the sea?

It can be evaluated for coastal applications. Pretreatment, coating system, salt deposition, fastener compatibility, cut edges and maintenance should all be considered.

Is the coating completely resistant to industrial pollution?

No coating should be described as universally immune to every industrial contaminant. The expected pollutants and cleaning environment should be reviewed for the specific project.

Does a Kynar 500 coating guarantee a fixed 20-year service life?

No universal service-life guarantee should be inferred from the resin brand alone. Project durability depends on the exact coating formulation, pigment, application, environment and any written warranty provided for the specific order.

What is EN 1396?

EN 1396 is a specification for coil-coated aluminum and aluminum-alloy sheet and strip for general applications, including relevant dimensional, mechanical, coating and performance requirements.

Can PE protective film be supplied?

Yes. Temporary protective film can be supplied for fabrication and installation. Tack, UV exposure and removal time should be confirmed for the project.

Can samples be supplied before facade approval?

Sample availability can be confirmed according to alloy, thickness, coating system, color and gloss. Physical color, coating and fabrication approval is recommended before large architectural orders.

What information should I provide for a quotation?

Please provide application, project location, alloy, temper, base thickness, coil width, coating system, coating film build, color, gloss, ΔE requirement, bend requirement, weathering specification, required QUALICOAT or other documentation, coil dimensions, quantity and destination.

Architectural PVDF coated aluminum coil for exterior cladding and curtain wall projects

Contact Us for Architectural PVDF Coil Samples

Previous: 
Next: 

Product Category

Related Products

Consult Us To Get Your Customized Aluminum Solution

We help you specify and source the coated aluminum you need, on time and within budget.

Products

Application

Quick links

Follow Us

Contact Us

    joey@cnchangsong.com
    +86-18602595888
   Building 2, Zhixing Business Plaza, No.25 North Street, Zhonglou District, Changzhou City, Jiangsu Province, China
    Chaoyang road, Konggang economic development area, Lianshui, Huai'an city, Jiangsu,China
© COPYRIGHT 2026 CHANGZHOU DINGANG METAL MATERIAL CO., LTD. ALL RIGHTS RESERVED.