Prepainted Aluminum Sheet Coil High Glossy Black 1200mm Feeding Width To 1160mm Effective Width for Metal Roof
You are here: Home » Brushed Surface » Prepainted Aluminum Coil & Sheet » Color Coated Aluminum Coil » Prepainted Aluminum Sheet Coil High Glossy Black 1200mm Feeding Width To 1160mm Effective Width for Metal Roof

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Prepainted Aluminum Sheet Coil High Glossy Black 1200mm Feeding Width To 1160mm Effective Width for Metal Roof

High gloss black prepainted aluminum coil for corrugated and profiled metal roofing, available in 3003-H14 or 5052 alloy with 1200mm feed width, 1160mm profile reference, custom gauges and PE/PVDF coatings.
Availability:
Quantity:

High Gloss Black Prepainted Aluminum Coil for Metal Roofing

High gloss black prepainted aluminum coil is supplied for roll forming into corrugated roofing sheets, trapezoidal roof panels, architectural roofing, flashing and other exterior metal components requiring a lightweight aluminum substrate and a factory-applied black finish.

The current product range includes AA3003-H14 and AA5052 aluminum options with common thicknesses of 0.68mm, 0.75mm, 0.8mm and 1.0mm. PE polyester and PVDF coating systems are available according to the required appearance, budget and exterior exposure.

A 1200mm flat feed width can be supplied for a roofing profile designed to achieve approximately 1160mm effective installed coverage. Because effective width depends on rib geometry, corrugation depth, side-lap design and roll-forming tooling, buyers should confirm the actual profile drawing before production.

For exterior roofing, alloy, temper, thickness, coating construction, gloss, color tolerance, forming radius and panel profile should be treated as one coordinated material specification rather than selected independently.

Request High Gloss Black Roofing Coil Pricing

Technical Specifications

Item

Available Specification

Roofing Notes

Product

High Gloss Black Prepainted Aluminum Coil

For corrugated, trapezoidal and compatible architectural roofing profiles

Primary Alloy

AA3003-H14

Practical balance of formability, moderate strength and corrosion resistance

Alternative Alloy

AA5052

Higher-strength option; final temper should be confirmed according to forming requirements

Common Thicknesses

0.68 / 0.75 / 0.8 / 1.0mm

Custom gauges can be discussed according to production capability

Feed Width

1200mm

Flat coil width entering the roofing roll former

Profile Reference

1160mm effective coverage

Must be confirmed against the actual profile drawing and overlap geometry

Cover-to-Feed Ratio

Approximately 96.7%

Reference only; the width difference is consumed by profile geometry and lap, not necessarily scrap

Color

High Gloss Jet Black

RAL or physical sample matching can be discussed

Gloss

High Gloss

Numerical 60° gloss target should be specified for repeat orders

Coating

PE Polyester / PVDF

Select according to exposure and appearance requirements

Top-Coat Thickness

Project-specific

Define primer and topcoat dry-film thickness in the purchase specification

Back Coating

Project-specific

Back-coat chemistry should match roof and condensation conditions

Color Tolerance

Project-specific

Define ΔE and measurement method where appearance consistency is critical

Protective Film

Optional

Useful where high-gloss surfaces require protection during profiling and transport

Coil ID

Customized

Provide roll-former decoiler requirement

Maximum Coil OD

Customized

Confirm equipment and container-loading limits

Coil Weight

Customized

Match crane, forklift and decoiler capacity

Typical Processing

Corrugation / Trapezoidal Roll Forming / Bending / Slitting

Machine compatibility should be verified with a trial

Material Reference

ASTM B209 / EN 485 where applicable

For substrate requirements

Coil-Coated Reference

EN 1396 where applicable

Relevant to coil-coated aluminum sheet and strip

1200mm Feed Width vs 1160mm Effective Width

Feed width and effective coverage width describe two different stages of roofing production.

1200mm Feed Width

The 1200mm dimension refers to the flat width of the aluminum coil before it enters the corrugating or roll-forming equipment.

1160mm Effective Coverage

The 1160mm reference refers to the intended installed coverage of a specific formed roofing profile after ribs, corrugations and side-lap geometry are taken into account.

The 40mm Difference Is Not Automatically Waste

When a 1200mm flat strip becomes a 1160mm effective roof panel, part of the apparent width difference is consumed by the three-dimensional profile and side overlap. It should not automatically be treated as scrap or material loss.

Confirm the Profile Drawing

Different corrugation and trapezoidal profiles can produce very different effective widths from the same 1200mm feed width. Provide the roll-former drawing, rib height, pitch and side-lap geometry before ordering.

Roof Profile Geometry Determines Effective Width

Effective coverage is determined by much more than coil width.

Profile Parameter

Influence

Rib Height

Higher ribs consume more flat strip width during forming

Wave / Rib Pitch

Controls the number and spacing of profiles across the panel

Corrugation Geometry

Changes the relationship between flat width and projected width

Side Lap

Reduces installed effective coverage

Edge Geometry

Can consume additional material for interlocking or overlap

Profile Depth

Influences stiffness and material consumption across the cross-section

AA3003-H14 for Roofing Roll Forming

AA3003-H14 provides a useful balance of formability, moderate strength and corrosion resistance for many profiled aluminum roofing applications.

Formability

3003-H14 can be roll formed into compatible corrugated and trapezoidal profiles where bending radii and tooling are properly designed.

Panel Stiffness

The formed ribs or corrugations provide most of the panel's geometric stiffness, while the substrate contributes the underlying mechanical properties.

General Roofing Use

AA3003-H14 is a practical starting specification for roofing manufacturers requiring easier forming than higher-strength 5xxx alloys.

AA5052 for Higher-Strength Roofing Components

AA5052 provides greater strength and strong corrosion resistance and can be considered where the roofing profile, handling requirements or service environment call for a higher-strength aluminum substrate.

Temper Must Be Confirmed

AA5052 should not be specified by alloy alone. The temper has a major influence on forming force, minimum radius and springback.

Tighter Profiles Require Testing

Where the roof profile contains tight folds or small-radius features, the selected 5052 temper should be tested on the actual roll-forming equipment before commercial production.

0.68mm, 0.75mm, 0.8mm and 1.0mm Thickness Options

Thickness

Selection Consideration

0.68mm

Light-to-medium roofing skin where profile geometry provides the required stiffness

0.75mm

Intermediate gauge balancing material weight, formability and panel rigidity

0.8mm

Practical gauge for many engineered aluminum roof profiles

1.0mm

Provides additional material stiffness; verify roll-former and bending capacity

The correct thickness should be selected according to panel profile, support spacing, wind pressure, span, roof slope and complete system design rather than material availability alone.

Discuss Alloy & Thickness Selection

High Gloss Black Finish

High gloss black provides a reflective architectural appearance for modern roofs, cladding, fascia and matching exterior metalwork.

Define Gloss Numerically

The term “high gloss” should be supplemented by a numerical 60° gloss target and tolerance when repeatable appearance is important.

Physical Color Master

A physical coated sample is recommended for final approval because gloss and coating chemistry can affect the perceived depth of black.

RAL or Custom Black

RAL references or customer physical samples can be used for compatible black color development. If RAL 9005 or another code is required, specify it explicitly in the purchase order.

Black Roofing and Solar Heat

Conventional black roofing generally absorbs more solar radiation than light-colored roofing.

Do Not Assume High Solar Reflectance

A high-gloss surface does not automatically mean high solar reflectance. Solar reflectance depends primarily on pigment chemistry and coating formulation rather than visible gloss alone.

Cool-Pigment Black Coatings

If the project requires a cool-roof black coating, request tested solar reflectance, thermal emittance and Solar Reflectance Index for the exact paint formulation.

Roof Insulation Still Matters

The aluminum skin is not thermal insulation. Building heat transfer depends on insulation, air spaces, ventilation, roof assembly and thermal bridges.

PE Polyester Coating

Polyester coating provides a cost-effective finish for compatible residential, commercial and light-industrial roofing applications.

Color and Gloss Flexibility

PE systems can support high-gloss black and other color programs where the required exterior durability matches the coating formulation.

No Universal 10–15 Year Claim

Polyester weathering performance depends on resin type, pigment, coating thickness, UV exposure, rainfall, pollution and maintenance. A fixed lifetime should not be applied to every project.

PVDF Coating

PVDF fluoropolymer coatings can be considered for demanding architectural roofing where improved resistance to UV weathering, chalking and long-term color change is required.

Specify the Complete PVDF System

A professional PVDF specification should identify the resin system, primer, topcoat dry-film thickness, pigment requirements and relevant coating tests.

No Universal 20–30 Year Claim

Long-term coating performance depends on the exact formulation, color, location and exposure. Any warranty should refer to the approved coating system rather than a generic PVDF label.

Coating Thickness Should Be Defined Clearly

For roofing procurement, the coating construction should identify pretreatment, primer, exposed topcoat and back coating.

Top-Side Dry Film

The exposed-side dry-film requirement should be selected according to whether the project uses standard PE, HDP or a higher-performance PVDF system.

Back Coat

The reverse side can use a service coating selected for handling, condensation exposure and panel construction.

Coating Flexibility During Corrugation

Prepainted aluminum is formed after coating, so paint flexibility must be compatible with the roof-profile geometry.

T-Bend

A T-bend or equivalent deformation test can be used to evaluate coating flexibility before roofing production.

Cross-Hatch Adhesion

Cross-hatch adhesion testing can provide a measurable requirement for coating bond to the pretreated aluminum substrate.

MEK Resistance

Where applicable to the paint chemistry, MEK double-rub testing can be used as a process-control indicator for coating cure.

Impact Resistance

Impact testing can help evaluate coating integrity after localized deformation.

Post-Forming Inspection

Trial roofing sheets should be inspected after forming for paint cracking, flaking, exposed aluminum, scratches and unacceptable surface marking.

Request Coating Test Data

Flatness, Camber and Edge Quality

Roofing roll-forming stability depends on coil shape as well as thickness.

Flatness

Edge wave and center buckle can affect finished panel appearance and tracking through the roll former.

Camber

Excessive longitudinal camber can cause tracking errors and inconsistent edge geometry during continuous roofing production.

Slit-Edge Quality

Burrs, nicks and damaged edges should be controlled where material is slit to the final roll-former feed width.

Coil Winding

Stable winding tension and aligned coil edges help reduce telescoping and feeding interruptions.

Aluminum Roofing vs Prepainted Steel Roofing

Aluminum and coated steel are different roofing substrates, each with advantages depending on design requirements.

Property

Prepainted Aluminum

Prepainted Steel

Density

Approximately 2.7g/cm³

Approximately 7.8g/cm³

Weight at Same Thickness

Significantly lower

Higher

Substrate Rust

Does not form iron rust

Steel can rust if metallic and paint protection are compromised

Strength at Same Gauge

Depends on aluminum alloy and temper

Often higher depending on steel grade

Marine Corrosion

Can provide good performance with suitable alloy and coating

Depends heavily on metallic coating, paint system and edge protection

Thermal Expansion

Higher than steel

Lower than aluminum

Roof-System Design

Must account for alloy, thickness, profile and expansion

Must account for steel grade, coating mass, profile and corrosion protection

Aluminum Is Not Structurally Equivalent at the Same Thickness

The lower density of aluminum does not mean a 0.8mm aluminum roofing panel automatically has the same structural capacity as a 0.8mm steel panel. Material strength, elastic modulus and profile geometry differ.

Aluminum Does Not Form Red Rust

Aluminum does not form iron oxide rust, but it can still experience corrosion under unsuitable chemical or galvanic conditions.

Service Life Is System-Specific

Neither aluminum nor steel should be assigned a fixed roof lifetime without considering coating, fasteners, installation, environment and maintenance.

Coastal and High-Humidity Environments

Aluminum can be attractive for humid and coastal roofing projects because it does not rely on an iron substrate, but the complete system still requires proper corrosion design.

Coating Selection

Demanding marine exposure may justify a higher-performance coating and careful control of scratches and exposed cut edges.

Galvanic Corrosion

Direct contact between aluminum and incompatible dissimilar metals in the presence of moisture can create galvanic corrosion. Fasteners and adjacent materials should be selected accordingly.

Maintenance

Marine salts and industrial deposits should not be allowed to accumulate indefinitely on coated roofing surfaces.

Corrugated Roofing Sheets

High gloss black prepainted aluminum coil can be roll formed into compatible sinusoidal or corrugated roofing profiles for residential, agricultural, commercial and light-industrial buildings.

The actual effective coverage must be calculated from the customer's corrugation geometry and side-lap requirement.

Trapezoidal Roofing Panels

Trapezoidal profiles provide deeper ribs and increased geometric stiffness and are widely used on factories, warehouses and commercial buildings.

Panel span and wind capacity must be calculated from the complete profile and attachment system rather than inferred from the aluminum coil alone.

Standing Seam Roofing

Selected aluminum gauges can also be used in compatible standing seam roofing systems, provided the alloy, temper, seam geometry and seaming equipment are suitable for the application.

Do Not Use the 1160mm Coverage Assumption for Standing Seam

Standing seam panel widths are defined by a different profile geometry, so the 1200mm-to-1160mm reference should only be used for the specific corrugated or profiled roof design for which it was developed.

Wind Uplift Is a System Property

Wind resistance depends on panel width, seam type, clips, clip spacing, fasteners and roof substrate.

Flashing, Fascia and Roof Trim

Matching high gloss black aluminum can be fabricated into ridge caps, valley flashing, eave trim, fascia, parapet caps and other compatible roof details.

Using matching coil for roof sheets and accessories can improve visual consistency when color and gloss are controlled to the same approved standard.

Rainwater Gutters and Drainage Components

Compatible aluminum coil can also be fabricated into gutters, downspouts and drainage accessories where the gauge and temper meet the forming requirements.

Gutter material specifications should be selected separately from roofing-panel specifications because bending geometry and required strip widths differ.

Wall Cladding and Architectural Panels

High gloss black prepainted aluminum can be used for compatible wall cladding, decorative profiles and architectural exterior elements where the complete panel system provides the required stiffness and attachment performance.

EN 1396 Coil-Coated Aluminum

EN 1396:2023 covers coil-coated wrought aluminum and aluminum-alloy sheet and strip for general applications and can be used as a relevant reference for prepainted roofing aluminum where specified.

The purchase specification should still identify alloy, temper, thickness, width, coating type, color, gloss, coating construction and required quality tests.

Inspection Item

Recommended Verification

Alloy & Temper

Verify against the approved purchase specification

Thickness

Verify nominal gauge and agreed tolerance

Feed Width

Verify 1200mm or approved machine input width

Effective Coverage

Verify the finished panel against the approved profile drawing

Flatness

Inspect edge wave and center buckle

Camber

Measure where roll-former tracking requires a defined limit

Slit Edge

Inspect burrs, nicks and damage

Color

Compare black finish against approved physical master

ΔE

Measure where instrumental color tolerance is contractual

Gloss

Verify against the approved 60° gloss range

Coating Thickness

Measure primer, exposed coating and back coat as specified

T-Bend

Evaluate coating flexibility for profile forming

Adhesion

Evaluate using agreed cross-hatch or equivalent method

MEK Resistance

Evaluate paint cure where applicable

Impact Resistance

Verify where specified

Surface Appearance

Inspect scratches, dents, streaks and coating defects

Winding Quality

Inspect telescoping, loose wraps and edge alignment

Roll-Forming Trial Before Bulk Production

A representative roll-forming trial is recommended whenever a new alloy, temper, gauge, coating system or roof profile is introduced.

The trial should use the customer's actual roofing machine, normal line speed and approved profile tooling.

Finished panels should be checked for effective width, profile accuracy, edge wave, springback, coating cracking, scratches and surface distortion.

If 1200mm feed width is expected to produce 1160mm effective coverage, this dimension should be verified during the trial before the bulk order is released.

Request Material for Roll-Forming Trials

Export Packaging and Container Loading

Prepainted aluminum coils should be packed to protect the high-gloss painted surface, coil edges and winding geometry during long-distance transportation.

Eye-to-Wall or Eye-to-Sky

Coil orientation can be selected according to coil dimensions, loading method and customer unloading equipment.

Moisture Protection

Water-resistant wrapping, moisture-resistant paper and suitable protective materials can be used to reduce exposure to condensation during sea transportation.

Edge Protection

Rigid edge protectors help reduce handling damage to slit edges and painted coil faces.

Container Loading

Loading plans should account for coil weight, support orientation, blocking, bracing and container payload limits.

Information Required for a Quotation

Please provide the roofing roll-former brand or profile drawing, including rib height, pitch, side-lap geometry and required effective coverage.

Confirm whether 1200mm feed width and 1160mm effective coverage are fixed project requirements.

Specify AA3003-H14 or the required AA5052 temper, together with thickness, thickness tolerance and mechanical-property requirements.

Provide the required black color reference, numerical gloss, PE or PVDF coating system, top/back film thickness and any T-bend, adhesion or MEK requirements.

Provide coil ID, maximum OD, target coil weight, quantity, packaging requirements and delivery destination.

For coastal projects, identify the approximate project environment so that alloy, coating and fastener compatibility can be reviewed.

Send Your Roofing Profile Specification

Frequently Asked Questions

What is high gloss black prepainted aluminum roofing coil?

It is aluminum coil coated with a factory-applied black organic finish and supplied for downstream roofing roll forming.

Which alloys are available?

The current product lists AA3003-H14 and AA5052 aluminum options.

What thicknesses are commonly supplied?

The current common specifications include 0.68mm, 0.75mm, 0.8mm and 1.0mm, with other gauges subject to production capability.

Does every 1200mm coil produce 1160mm effective roofing width?

No. Effective width depends on the specific roofing profile, corrugation depth, rib pitch and side-lap design. The 1160mm value must be confirmed against the actual profile drawing.

Is the 40mm difference between 1200mm and 1160mm waste?

Not necessarily. Much of the width difference is consumed by the three-dimensional roof profile and overlap geometry rather than removed as scrap.

Will 1200mm fit every South American roofing machine?

No universal compatibility should be assumed. Provide the exact machine model or profile drawing before ordering.

What is the difference between 3003 and 5052 aluminum?

AA3003 generally provides easier forming with moderate strength, while AA5052 provides higher strength and strong corrosion resistance. The final choice depends on profile geometry and temper.

Is aluminum roofing stronger than steel at the same thickness?

Not automatically. Aluminum is lighter, but steel and aluminum have different strength and elastic-modulus characteristics. Finished roof performance depends on grade, thickness and panel geometry.

Is aluminum completely rust-proof?

Aluminum does not form iron rust, but it can still corrode under aggressive chemical or galvanic conditions.

What is the difference between PE and PVDF coating?

PE polyester is a cost-effective coating for compatible roofing projects, while PVDF is generally selected for more demanding long-term architectural weathering.

Does PE always last 10–15 years?

No fixed service life applies to every PE coating. Performance depends on resin formulation, color, exposure and maintenance.

Does PVDF always last 20–30 years?

No universal lifetime applies to every PVDF coating. Any warranty should refer to the actual approved coating system and project environment.

Does high-gloss black roofing have high solar reflectance?

Not necessarily. Standard black pigments generally absorb significant solar energy. A tested cool-pigment formulation is required if high solar reflectance is a project requirement.

Can black aluminum roofing reduce air-conditioning use by 25%?

No universal percentage should be assumed. Building energy performance depends on coating reflectance, insulation, ventilation, climate, roof geometry and the complete building envelope.

Can this coil be used for corrugated roofs?

Yes, where thickness, alloy, temper and feed width are compatible with the corrugating machine and profile design.

Can it be used for trapezoidal roofing?

Yes. Trapezoidal profiles can be produced from compatible prepainted aluminum coil after the roll-forming requirements are confirmed.

Can it be used for standing seam roofing?

Selected specifications can be evaluated for standing seam systems, but the seam profile, clips, seaming equipment and roof-system engineering must be assessed separately.

Can the same material be used for flashing and trim?

Yes, compatible gauges can be fabricated into matching fascia, flashing, ridge caps and architectural trim.

Why is T-bend testing important?

T-bend testing evaluates whether the coating remains attached during severe deformation similar to downstream forming operations.

Why are flatness and camber important?

Poor flatness or excessive camber can cause tracking problems, profile distortion and visual waviness on long roofing sheets.

Can a protective film be applied?

Protective film can be discussed where the high-gloss surface requires additional protection during forming, transport or installation.

Is EN 1396 relevant?

EN 1396:2023 is relevant to coil-coated aluminum sheet and strip for general applications and can be referenced where applicable.

Can samples be tested on our roofing machine?

A trial coil or sample is recommended for confirming feed width, effective profile width, coating flexibility and machine compatibility before bulk production.

What information is required for a quotation?

Please provide profile drawing, feed width, effective width, alloy, temper, thickness, black color reference, gloss, coating type, coil dimensions, quantity and destination.

Request a Quote for High Gloss Black Aluminum Roofing Coil

If you manufacture corrugated roofing sheets, trapezoidal panels, standing seam products, flashing or architectural roof components, send us your roll-forming profile and coil requirements.

Available options include AA3003-H14 and AA5052 aluminum, common 0.68–1.0mm thicknesses, high gloss black PE or PVDF coatings and 1200mm feed-width configurations for compatible roof profiles.

Request a Quotation

Previous: 
Next: 

Product Category

Related Products

Consult Us To Get Your Customized Aluminum Solution

We help you specify and source the coated aluminum you need, on time and within budget.

Products

Application

Quick links

Follow Us

Contact Us

    joey@cnchangsong.com
    +86-18602595888
   Building 2, Zhixing Business Plaza, No.25 North Street, Zhonglou District, Changzhou City, Jiangsu Province, China
    Chaoyang road, Konggang economic development area, Lianshui, Huai'an city, Jiangsu,China
© COPYRIGHT 2026 CHANGZHOU DINGANG METAL MATERIAL CO., LTD. ALL RIGHTS RESERVED.