Architectural coated aluminum coil is supplied as a prefinished metallic skin for high-rise curtain wall panels, solid aluminum cladding, mineral-core composite panels, cassette systems, ceilings and other building-envelope components where stringent reaction-to-fire requirements apply.
The product range includes architectural aluminum alloys such as AA3003, AA3004, AA3005, AA3105, AA5005 and AA5052, together with other alloy and temper combinations subject to project confirmation. PVDF coating is available for exterior facade applications requiring long-term color and weathering performance, while PE coating can be specified for suitable interior or sheltered applications.
Where an EN 13501-1 A2-s1,d0 classification is required, the fire-classification report must apply to the exact tested product or panel construction. In North American projects, ASTM E84, NFPA 285 and other fire requirements should be evaluated separately according to the material, finished wall assembly and local building code.
Request a High-Rise Facade Coil Quote Request Fire & Coating Documents
Under EN 13501-1, A2 represents a high reaction-to-fire performance level in which the tested construction makes only a very limited contribution to fire. The classification applies to the product configuration covered by the corresponding classification and test reports.
The s1 suffix indicates the lowest smoke-production category within the applicable EN 13501-1 smoke classifications. It should only be stated where the exact tested product is covered by a valid classification report.
The d0 designation means no flaming droplets or particles are observed within the specified test period. It is part of the tested product classification and should not be inferred from the aluminum substrate alone.
Fire performance can be influenced by the aluminum thickness, coating chemistry, coating mass, primer, adhesive, core, backing and mounting configuration. Buyers should therefore verify that the submitted fire report covers the product or facade construction actually proposed for the project.
EN 13501-1 is a European classification system for the reaction-to-fire performance of construction products. If A2-s1,d0 is specified, the classification report should identify the tested product, construction and relevant scope of application.
ASTM E84 evaluates surface-burning characteristics such as flame spread and smoke developed under the prescribed test conditions. A Class A result under ASTM E84 should not be interpreted as an independent determination that a material is noncombustible.
NFPA 285 evaluates vertical and lateral flame propagation in complete exterior non-load-bearing wall assemblies containing combustible components. Compliance belongs to the tested wall assembly or an accepted engineering evaluation, not to an aluminum coil by itself.
Parameter | Detailed Information |
|---|---|
Main Product | Architectural Prepainted Aluminum Coil for High-Rise Facade and Fire-Rated Panel Systems |
Recommended Architectural Alloys | 3003 / 3004 / 3005 / 3105 / 5005 / 5052 |
Other Available Alloys | 1050 / 1060 / 1100 / 5754 / 5083 / 6061 / 8011, subject to coating and fabrication requirements |
Available Tempers | O / H12 / H14 / H16 / H18 / H24 / H26 / H32 / H34, subject to alloy availability |
Thickness Range | 0.2 mm – 1.6 mm |
Width Range | 30 mm – 1600 mm |
Inner Core Diameter | 76 mm / 150 mm / 405 mm / 505 mm |
Color Options | RAL / Pantone / Custom color matching against approved physical sample |
PVDF Coating Thickness | ≥25 μm according to confirmed coating construction |
PE Coating Thickness | ≥18 μm according to confirmed coating construction |
Typical Exterior Coating | PVDF architectural coating for suitable exterior facade applications |
Substrate Standard | ASTM B209/B209M or other agreed aluminum sheet and coil specification where applicable |
Fire Documentation | EN 13501-1, ASTM E84 or other fire documents supplied only where applicable to the exact tested product or system |
Typical Fabrication | Slitting / Cutting / Routing / Folding / Bending / Cassette Fabrication / Panel Lamination |
Protective Film | Available with specified peel strength and fabrication requirements |
Standard Packaging | Export-grade wooden pallets, Eye-to-Wall or Eye-to-Sky configuration |
Minimum Order Quantity | 3 metric tons per specification |
Delivery Cycle | 30–45 working days, subject to color, alloy, coating and order quantity |
Loading Ports | Shanghai / Ningbo / Qingdao / Tianjin and other major ports |
Payment Terms | 30% T/T deposit, 70% balance against B/L copy; L/C at sight |
Specification note: Fire classification, coating performance, structural suitability and facade-system compliance must be confirmed against the exact product configuration, project drawings, test reports and local code requirements. A coating designation or aluminum alloy alone does not establish the fire classification of a complete facade assembly.
Send Your Alloy, Gauge & Fire Requirements
3xxx-series aluminum alloys provide a practical combination of formability, corrosion resistance and moderate strength for architectural panel skins, fascia, ceiling panels and folded facade components. Final alloy and temper should be selected according to panel dimensions and forming severity.
AA5005 is widely used in architectural applications where a balance of corrosion resistance, surface quality and fabrication performance is required. It can be specified for coated facade panels and related exterior components.
AA5052 provides greater strength than many 3xxx-series alloys and can be considered for fabricated panels and components requiring additional mechanical performance. Structural capacity, wind resistance and fixing design must still be calculated at the finished panel and support-system level.
PVDF coating can be specified for high-rise facade skins exposed to sunlight, rain and long-term outdoor weathering. Actual color and gloss retention depend on the complete coating formulation, pigment, film thickness, orientation and climate.
Projects exposed to airborne chlorides, industrial pollutants or aggressive atmospheric conditions should specify pretreatment, primer, topcoat, backside protection and corrosion-test requirements. Salt-spray test duration alone should not be treated as a direct prediction of facade service life.
RAL, Pantone and custom architectural colors can be matched against an approved physical sample. Large facade projects should define an acceptable color-difference tolerance and retain a master sample for repeat production and phased deliveries.
Coated aluminum can be converted into suitable cassette panels and folded architectural components. Alloy, temper, gauge, minimum bend radius and coating flexibility should be confirmed before production, particularly for deep returns, narrow hems and complex geometries.
A universal 2T no-crack guarantee should not be assumed for every alloy, gauge and coating system. Where tight forming is required, T-bend testing or an actual fabrication trial should be performed using material representative of the production order.
Tension leveling and dimensional control can improve incoming coil flatness, but visible oil canning in a completed facade also depends on panel size, gauge, forming, fixing method, thermal expansion and support geometry. Final appearance should be evaluated at panel-system level.
Inspection can be configured according to the approved project specification. High-rise facade projects should identify required certificates and test methods before production so that material documents match the final submittal package.
Alloy and temper verification
Substrate thickness and width measurement
Coating thickness measurement
Color and gloss inspection
Coating adhesion testing where specified
T-bend or fabrication testing where required
Surface-defect and flatness inspection
MTC according to the ordered aluminum specification
Fire-classification documentation where applicable to the exact tested product or panel system
Request Project Submittal Documents
Solid colors, metallic effects and custom architectural finishes can be developed against RAL, Pantone or approved physical samples. Large projects can specify batch color-control requirements for phased delivery.
Removable protective film can be laminated to the coated face to reduce scratching during slitting, routing, folding, CNC processing, handling and installation. Adhesion level, UV exposure time and removal requirements should be confirmed before production.
Coils can be protected with moisture-resistant wrapping, kraft paper, edge protection and export-grade wooden pallets. Eye-to-Wall or Eye-to-Sky loading configurations are available according to coil dimensions, handling equipment and shipping requirements.
Prefinished aluminum coil can be converted into skins for unitized curtain wall cassettes, solid aluminum panels and related facade components. Wind-load resistance and structural adequacy must be established from the finished panel, stiffener, fixing and support design rather than the coil alone.
Coated aluminum can serve as the outer metallic skin in mineral-core or other fire-rated composite panel constructions. The A2 classification belongs to the tested finished panel construction and should be supported by the relevant classification report.
Applications include office towers, high-rise residential projects, hotels and mixed-use developments where facade material, fire performance, coating durability and appearance must satisfy the approved project specification.
Coated aluminum is suitable as a surface material for approved cladding, ceiling and architectural panel systems used in airports, rail terminals, metro stations and other high-occupancy public facilities.
Suitable configurations can also be used as finished aluminum skins for ceilings, wall panels and equipment enclosures where the project specifies particular reaction-to-fire, smoke, surface-cleanliness or coating requirements.
For accurate pricing and technical review, please provide alloy, temper, thickness, width, coil ID, coating system, coating thickness, RAL or custom color, gloss, quantity, destination and preferred packing configuration.
For fire-sensitive facade projects, also provide the required EN 13501-1 classification, ASTM E84 criteria, NFPA 285 assembly requirement or other local fire standard, together with the proposed panel construction and required submittal documents.
For cassette panels, provide the panel thickness, dimensions, return depth, bend radius, routing or folding method and any required T-bend or coating-flexibility criteria.
Request a Custom Facade Coil Specification
No. An EN 13501-1 classification applies to the product configuration covered by the relevant test and classification report. Coating chemistry, coating mass, substrate thickness and product construction can affect the classification.
A2 is a high reaction-to-fire classification with very limited contribution to fire. s1 indicates low smoke production, while d0 indicates no flaming droplets or particles within the specified test period.
No. ASTM E84 measures surface-burning characteristics. A Class A result should not be used by itself to classify or define a material as noncombustible.
No. NFPA 285 evaluates fire propagation through and across an exterior wall assembly containing specified components. The result applies to the tested wall construction or an accepted engineering evaluation.
AA3003, AA3004, AA3005, AA3105 and AA5005 are practical architectural options, while AA5052 can provide greater strength. Final selection depends on panel geometry, forming method, design loads, corrosion environment and project specification.
It depends on the alloy, temper, substrate thickness, coating system and bending method. If a 2T requirement is critical, it should be included in the purchase specification and verified using the agreed T-bend method or production trial.
For large facade projects, buyers should approve a physical master sample and define the required color-difference measurement method and acceptable tolerance. A universal Delta E value should not be assumed for every solid, metallic or special-effect color.
Yes, suitable alloy and coating systems can be specified for coastal environments. Pretreatment, primer, PVDF topcoat, backside protection, fastener compatibility and cut-edge design should all be reviewed for chloride exposure.
Request the classification or test report required by the project and verify that its product description, thickness, coating and system construction correspond to the material being supplied. For facade assemblies, additional wall-system testing may also be required.
Please provide alloy, temper, thickness, width, coating system, coating thickness, color, gloss, coil ID, quantity and destination. For high-rise facade projects, also provide the required fire classification and panel-system information.
If you are preparing a high-rise facade, curtain wall, public infrastructure or fire-rated panel project, send us your alloy, gauge, coating, color, panel construction, fire-performance requirements and purchase quantity. Our technical sales team can review the material specification and prepare a quotation and sample proposal.