Aluminum Alloy 8011
Dingang
| Aluminum Alloy: | |
|---|---|
| Aluminum Foil Thickness: | |
| Color Options:: | |
| ID: | |
| Availability: | |
| Quantity: | |
Printed pharmaceutical aluminum foil is used as a barrier, printing and sealing component in blister packs, strip packs, sachets and other flexible pharmaceutical packaging structures for tablets, capsules, powders, granules and other moisture- or light-sensitive products.
The current product information identifies AA8011-O soft aluminum foil with a printable surface and a surface-wetting reference of 38 dynes/cm or higher. The final alloy, temper, foil thickness, coating structure and sealing layer must be selected according to the actual pharmaceutical packaging format rather than treating one foil specification as universal for all applications.
Conventional push-through blister lidding, soft strip-pack laminates, pharmaceutical sachets and cold-form blister structures use different aluminum tempers, thicknesses and coating systems. Buyers should therefore provide the exact package structure, forming web, sealing substrate, pharmaceutical product and packaging-machine requirements before commercial supply.
Request Pharmaceutical Foil Details
Technical Property | Current / Available Reference | Purchasing Notes |
Product Type | Printed / Coated Pharmaceutical Aluminum Foil | Final structure depends on blister, strip-pack or sachet application |
Current Base Alloy | AA8011 | Other alloys and tempers are used for different pharmaceutical packaging formats |
Current Temper Reference | O / Soft | Suitable for compatible flexible or laminated structures; conventional PTP lidding commonly uses hard temper instead |
Surface Wettability | Current reference ≥38 dynes/cm | Relevant to primer, ink, lacquer and adhesive wetting |
Printing | Custom pharmaceutical printing | Artwork, colors, text, repeat and registration should be approved before production |
Protective Overprint Lacquer | Project-specific | Used where printed graphics require additional abrasion or heat protection |
Heat-Seal Lacquer | Project-specific | Must match the forming web such as the specified PVC, PVDC-coated PVC or another approved substrate |
Moisture Barrier | Current source reference WVTR <0.1g/m²·24h | Use only with defined test method, sample construction and test conditions |
Oxygen Barrier | Current source reference OTR <0.1cm³/m²·24h | Use only with defined test conditions and the approved commercial structure |
Foil Thickness | To be confirmed by packaging structure | PTP lidding, strip foil and sachet laminates use different typical gauge ranges |
Finished Width | Customized | Specify according to blister or strip-pack machine |
Core ID | Project-specific | Common pharmaceutical converting equipment can use 76mm or 152mm cores; confirm actual requirement |
Maximum Roll OD | Customized | Specify machine unwind limitation |
Winding Direction | Customized | Specify print-side and HSL-side orientation |
Splices | To be agreed | Maximum quantity, splice method and identification should be defined |
Documentation | Project-specific | Define required material, coating, printing, test and regulatory documents before order confirmation |
The correct aluminum foil cannot be selected from the drug name alone. The first step is to identify whether the project uses push-through blister lidding, strip packaging, sachets, pouches or cold-form blister material.
Packaging Format | Common Aluminum Configuration | Main Function |
PTP Blister Lidding | Hard aluminum foil with print primer / printing / HSL | Push-through lidding for tablets and capsules |
Strip Pack | Soft foil or foil laminate, often with polymer sealing layers | Individual sealing of tablets or capsules between two webs |
Powder / Granule Sachet | Multilayer laminate containing aluminum as the barrier layer | Barrier pouch for powders, granules and unit-dose products |
Cold-Form Blister | OPA / Aluminum / PVC or another validated cold-form laminate | Aluminum-based forming web for high-barrier cavities |
Diagnostic / Reagent Pouch | Foil laminate selected according to reagent sensitivity and sealing process | Moisture, oxygen and light barrier |
Conventional push-through blister lidding is normally based on hard-temper aluminum foil rather than soft 8011-O.
A common market construction is protective overprint lacquer or primer / printing ink / hard aluminum foil / heat-seal lacquer.
Commercial PTP lidding commonly uses AA8011-H18 or another approved hard foil in approximately 20μm, 25μm or 30μm gauges.
These are industry references rather than universal product guarantees. The selected gauge should match tablet size, push-through behavior, package design and customer specification.
A printed PTP construction can be represented as:
Overprint Lacquer / Printing Ink / Aluminum Foil / Heat-Seal Lacquer
The outer lacquer protects the print, the aluminum provides the barrier and push-through lid, and the heat-seal lacquer bonds the foil to the approved forming web.
Commercial pharmaceutical lidding products can use different HSL coating weights according to the resin system and forming substrate.
The order should identify coating weight, compatible forming material and required seal performance rather than describing the foil only as “heat sealable.”
Request PTP Lidding Specifications
PTP aluminum foil does not seal to every blister material using the same lacquer and processing conditions.
Where PVC is used as the forming web, the HSL should be specifically compatible with the selected PVC grade and packaging process.
PVDC-coated forming webs can require different lacquer compatibility and sealing conditions from standard PVC.
PP, PET-based materials and other specialty forming webs should only be paired with lidding lacquer that has been validated for that specific substrate.
A pharmaceutical blister seal depends on lacquer chemistry, coating weight, sealing temperature, pressure, dwell time and the forming web.
Required seal strength should be stated numerically using an agreed test method and defined sealing conditions.
The lacquer should provide a suitable processing window for the customer's packaging line without damaging print or forming web.
Seal performance should be qualified using the actual production pressure and dwell time because laboratory conditions may not duplicate a high-speed blister line.
Seal integrity should be evaluated on the finished blister or package using the pharmaceutical manufacturer's validated leak or package-integrity procedure.
Strip packaging differs from PTP blister lidding. Tablets or capsules are sealed between two flexible webs rather than pushed through a single hard aluminum lid.
Strip-pack foil commonly uses a soft aluminum or aluminum-laminate construction with a polymer layer that provides sealing and protects the foil during packaging.
Soft foil such as compatible 8011-O or another approved soft-temper alloy can be evaluated where the strip structure requires flexibility and folding.
Commercial strip-pack structures can use aluminum approximately 30–40μm thick together with polyethylene or another sealing layer.
The exact structure, polymer gauge and sealing system must be confirmed according to the medicine and strip-pack machine.
Where two strip webs seal directly around the dosage unit, the sealing layer and web orientation should be specified for both sides of the package.
Sensitive powders, granules and unit-dose pharmaceutical products are often packaged in multilayer flexible laminates rather than unsupported aluminum foil.
A pharmaceutical sachet can include an outer printable film or paper, an adhesive layer, aluminum foil as the barrier component and an inner polymer sealing layer.
The aluminum layer contributes protection against moisture, oxygen and light when it remains continuous and undamaged.
The inner polymer provides the actual heat-sealing surface. Its compatibility with the pharmaceutical product and sealing process should be evaluated separately.
Cold-form blister foil should not be confused with printed PTP lidding foil.
Cold-form structures typically use a thick, ductile aluminum layer in a multilayer laminate that is mechanically formed into the blister cavity.
AA8021 or AA8079 in soft temper is commonly considered for cold-form applications, with aluminum gauges around 45–50μm being widely used as a market reference.
A common structure is:
OPA / Aluminum / PVC
The polyamide layer supports forming strength, aluminum provides the primary barrier, and the PVC or other approved inner layer provides the sealing interface.
Cold-form foil should therefore be specified separately from both conventional PTP lidding and soft strip-pack foil.
Intact aluminum foil provides very high resistance to moisture, oxygen, other gases and light, making it valuable for pharmaceutical barrier packaging.
Thin foil should nevertheless not be described as universally guaranteeing an absolute barrier after every converting and packaging process.
Where barrier performance is critical, allowable pinhole count and maximum pinhole size should be included in the purchase specification.
Soft laminates used for strip packs and sachets can experience flexing and sharp folding. Barrier validation should therefore reflect the converted package rather than only flat foil.
Moisture protection, leak resistance and package integrity should be verified on the final blister, strip or sachet system containing the actual forming and sealing materials.
The existing product data includes OTR and WVTR values below 0.1 per square meter per 24 hours.
Such values should only be used as contractual specifications when the sample structure, temperature, relative humidity, conditioning and test method are clearly identified.
Barrier Test | Information to Specify |
OTR | Value, units, temperature, RH, test method and specimen structure |
WVTR | Value, units, temperature, RH, test method and specimen structure |
Sample Type | Bare foil / coated foil / laminate / finished blister or pouch |
Conditioning | Pre-test conditioning period and environment where applicable |
Damage State | Flat / formed / folded / flex-conditioned as applicable |
Printed pharmaceutical foil normally uses a controlled coating and ink system rather than applying ink directly to untreated aluminum.
Layer | Typical Function |
Protective Overprint Lacquer | Protects printed information from abrasion and sealing heat where required |
Printing Ink | Product name, strength, batch information, branding and approved identification graphics |
Print Primer | Promotes adhesion between the aluminum and compatible ink system |
Aluminum Foil | Barrier and structural metallic layer |
Heat-Seal Lacquer | Provides sealing compatibility with the approved blister forming web |
Printed information on pharmaceutical foil must remain legible throughout converting, sealing, cutting, storage and use.
Highly reflective foil can reduce text readability under strong lighting. Matte or controlled-reflectivity surfaces can be considered where package-design requirements prioritize legibility.
Text and background colors should provide sufficient visual contrast for product name, strength, batch and expiry information.
Critical information should repeat at a frequency that minimizes the risk of losing essential identification when blister strips are cut.
Artwork orientation, repeat length and registration should match the blister layout and cutting pattern.
The current product information lists surface wettability of at least 38 dynes/cm.
Surface energy is useful for controlling wetting of primer and printing ink but should not be interpreted as a guarantee of permanent ink adhesion.
Residual rolling oil should be controlled before primer, printing or heat-seal lacquer application.
The print primer should be compatible with the selected solvent-based, water-based or other approved pharmaceutical printing system.
Tape, rub or other agreed tests can be used to verify print adhesion after curing and after representative sealing conditions.
Printing and protective lacquer should tolerate the sealing process without unacceptable discoloration, transfer or loss of legibility.
Where solvent-based primers, inks, adhesives or lacquers are used, the finished structure should meet the customer's residual-solvent and curing requirements.
Required analytical methods and limits should be included in the pharmaceutical packaging specification before commercial production.
Custom pharmaceutical printing can include approved brand graphics, dosage information, registration marks and product-identification features.
Security or anti-counterfeiting features should only be specified where the required printing technology, inspection method and artwork controls are supported by the production process.
Small pharmaceutical text requires controlled plate preparation, ink transfer and print registration to remain readable after slitting and sealing.
Batch number, manufacturing date and expiry date may be applied during downstream pharmaceutical packaging depending on the customer's line and regulatory process.
Roll Parameter | Information to Provide |
Packaging Machine | Manufacturer and model where available |
Packaging Format | PTP blister / strip pack / sachet / pouch |
Finished Width | Exact machine-feed width |
Core ID | Specify required core; 76mm and 152mm are common market references |
Maximum Roll OD | Provide unwind limitation |
Roll Weight | Provide target and maximum weight |
Print Repeat | Match blister or package pitch |
Registration | Define artwork-to-package alignment tolerance |
Winding Direction | Define printed side and HSL / sealant side |
Splices | Define maximum quantity, tape type and identification method |
Edge Quality | Define nicks, burrs, edge damage and telescoping requirements |
Send Your Packaging Line Specifications
Hard printed aluminum foil with a suitable heat-seal lacquer can be used as push-through lidding for compatible PVC, PVDC-coated or other validated forming webs.
Soft foil laminates can be used for compatible strip packaging where individual dosage units are sealed between two flexible webs.
Aluminum-containing laminates can provide strong moisture, oxygen and light protection for hygroscopic or sensitive unit-dose powders and granules.
Foil laminates can be considered for sensitive test components and reagents where the complete package requires strong moisture and gas protection.
Specialty pharmaceutical dosage forms can use aluminum-containing laminates where the foil gauge, polymer layers, sealing system and chemical compatibility have been validated for the exact product.
Aluminum foil itself is only one component of a pharmaceutical container-closure system.
Compatibility should consider the actual drug formulation together with the foil, primer, ink, heat-seal lacquer, adhesive, polymer layers and any surface that can contact the dosage form.
Where lacquer or polymer contacts the medicine directly, documentation should apply to that exact contact layer and intended conditions of use.
Where required by the customer or applicable pharmaceutical specification, testing should be carried out on the relevant coating or laminate structure rather than inferred from the aluminum alloy alone.
The pharmaceutical manufacturer should demonstrate that the selected package provides sufficient protection throughout the intended shelf life under the applicable stability program.
No printed aluminum foil should be represented as universally compliant for every pharmaceutical market solely because it uses AA8011 aluminum.
The required documentation depends on the complete packaging construction, pharmaceutical dosage form, direct-contact surface, intended market and customer's registered packaging specification.
For U.S. pharmaceutical applications, the complete container-closure system should be evaluated for suitability, protection, safety and compatibility according to the applicable drug-product requirements.
For Saudi or GCC projects, provide the required packaging, labeling, test and registration documentation before production. Blister-foil artwork should also consider readability and glare control.
For European projects, provide the exact pharmaceutical packaging specification and required pharmacopoeial, regulatory or customer documentation for the complete structure rather than relying on a general “EU Pharmacopoeia compliant” statement.
Aluminum foil is rolled to the specified gauge and temper according to the selected pharmaceutical packaging format.
Processing conditions are selected to achieve the required hard or soft temper rather than using the same temper for every pharmaceutical structure.
Residual rolling oils and surface contamination are controlled before primer, printing, lacquer or lamination.
A compatible primer can be applied to support printing adhesion according to the approved ink system.
Approved artwork is printed according to the specified color, repeat, registration and legibility requirements.
A compatible protective lacquer can be applied over printed graphics where required by the packaging process.
For PTP lidding, the seal side is coated with a lacquer selected for the approved forming web.
For strip packs, sachets and specialty structures, aluminum can be laminated with compatible polymer film or paper according to the approved package construction.
Finished material is slit and rewound according to packaging-machine width, core, roll OD, print orientation and winding requirements.
Inspection Item | Recommended Control |
Alloy & Temper | Verify against the approved blister, strip or sachet specification |
Foil Thickness | Measure nominal gauge and agreed tolerance |
Pinhole Level | Specify allowable count and size where required |
Surface Cleanliness | Inspect rolling-oil residue, contamination, stains and defects |
Surface Wettability | Verify where primer or printing requires a defined surface-energy target |
Print Color | Compare against approved artwork or color standard |
Print Registration | Measure against blister pitch and artwork tolerance |
Print Legibility | Check text clarity after printing, slitting and representative sealing |
Ink Adhesion | Evaluate using agreed tape, rub or other test |
Protective Lacquer | Verify coat weight, cure and print protection where specified |
HSL Coat Weight | Measure against the approved blister-lidding specification |
Heat-Seal Strength | Test against the actual forming web using defined temperature, pressure and dwell time |
Residual Solvents | Test where required by ink, coating, adhesive or customer specification |
Barrier Performance | Evaluate the relevant foil, laminate or finished package using agreed test conditions |
Width | Verify against packaging-machine specification |
Edge Quality | Inspect nicks, burrs, tears and slit damage |
Roll Winding | Inspect telescoping, edge alignment and winding stability |
Traceability | Maintain production-lot identification according to the agreed customer quality system |
Documentation | Verify all required material, coating, printing and regulatory records before release |
A representative trial is recommended whenever a new foil temper, gauge, coating system, forming web, printing system or packaging machine is introduced.
For PTP blister lidding, the trial should evaluate web feeding, print registration, seal quality, push-through behavior, blister cutting and package integrity.
For strip packs and sachets, evaluate web tracking, heat sealing, laminate adhesion, fold behavior, edge quality and finished-package leakage.
After successful qualification, alloy, temper, gauge, primer, ink, lacquer, HSL or laminate structure, roll dimensions and packaging-line conditions can be retained as the approved repeat-order specification.
Request Samples for Packaging Trials
For an accurate quotation, first specify whether the project requires PTP blister lidding, pharmaceutical strip foil, sachet laminate, cold-form blister material or another packaging structure.
Provide the drug dosage form, packaging-machine type, aluminum alloy and temper where already defined, foil thickness, finished width and order quantity.
For PTP lidding, provide the blister forming web, heat-seal lacquer requirement, required coating weight, seal strength and production sealing conditions.
For printed material, provide artwork, colors, print repeat, blister pitch, text requirements, registration tolerance and winding direction.
For strip and sachet structures, provide the complete laminate construction, adhesive or polymer layers, sealing requirements and barrier targets.
Also identify the destination market and all required material, migration, extractables, coating, printing, pharmacopoeial or customer-specific documentation before order confirmation.
Send Your Pharmaceutical Foil Specification
It is aluminum foil that has been prepared for printing, coating, sealing or lamination for use in pharmaceutical blister, strip-pack, sachet and related packaging structures.
No. Different pharmaceutical packages require different foil tempers and structures. Soft 8011-O can be considered for compatible flexible or laminated structures, while conventional push-through blister lidding commonly uses hard foil.
AA8011-H18 is a common market choice for conventional push-through lidding, although the final alloy and temper should follow the approved pharmaceutical packaging specification.
20μm, 25μm and 30μm are common commercial references for hard blister lidding foil.
A conventional printed structure can use protective overprint lacquer / ink / aluminum foil / heat-seal lacquer.
It provides the sealing interface between the aluminum lidding and the approved blister forming web.
Not automatically. The lacquer must be compatible with the exact forming substrate, and sealing conditions should be validated on the customer's line.
Strip foil is generally a flexible aluminum or aluminum-laminate web used to seal individual tablets or capsules between two packaging webs.
No. PTP lidding is normally hard push-through foil, while strip packaging usually uses a softer flexible laminate with a separate sealing layer.
Approximately 30–40μm aluminum is a common market reference for some strip-pack laminates, but the final structure should be specified according to the medicine and packaging line.
Cold-form aluminum is a thick, ductile aluminum barrier layer used inside a multilayer forming web that is mechanically formed into blister cavities.
AA8021-O and AA8079-O are common industry references for suitable cold-form aluminum layers.
No. Its relevance is primarily related to ductility and forming behavior in suitable soft-foil and laminate applications rather than printing alone.
Yes, aluminum can form the barrier layer in suitable printed sachet or pouch laminates for moisture-sensitive powders and granules.
No. Sterility or microbiological protection is a property of the complete packaging system and pharmaceutical manufacturing process, not the aluminum alloy alone.
Not necessarily. Pinhole acceptance depends on foil thickness, quality requirements and the applicable pharmaceutical specification.
No. Barrier values should only be quoted together with the exact foil or laminate structure, test method, temperature and humidity conditions.
Product name, strength and other critical information must remain readable after printing, sealing and cutting of the blister strip.
A less reflective surface can reduce glare and improve readability of printed pharmaceutical information under strong lighting.
No. Surface energy supports wetting, but final adhesion depends on surface cleanliness, primer, ink chemistry, curing and protective coating.
Security and identification features can be discussed where the required printing technology, inspection method and artwork controls are available for the project.
No. Pharmaceutical packaging suitability must be evaluated for the complete container-closure system and its exact coatings, sealants, inks and contact conditions.
No blanket claim should be made from the alloy alone. The exact commercial structure and required Saudi pharmaceutical packaging documentation should be confirmed before production.
No. Required pharmacopoeial or regulatory documentation should be identified for the exact packaging structure and intended pharmaceutical application.
The lidding must remain securely bonded during production, transport and storage while providing the opening behavior required by the approved blister design.
Yes. Representative machine trials are recommended when a new foil gauge, coating, forming web, artwork or packaging line is introduced.
Please provide packaging format, dosage form, foil structure, alloy and temper where specified, thickness, width, forming web, HSL or laminate requirements, artwork, machine information, destination market and required documentation.
If you require printed foil for pharmaceutical blister lidding, strip packaging, sachets or sensitive barrier applications, send us the complete package structure and packaging-machine specification.
We can discuss printed aluminum foil, primer and lacquer systems, slit widths, roll dimensions, pharmaceutical artwork and project-specific documentation according to the approved packaging construction.
Products
Application
Quick links
Contact Us